Commit Graph

51 Commits

Author SHA1 Message Date
Uwe Hermann ba7dd8bbb8 Replace 'probe' with 'channel' in most places.
Also, consistently use 'ch' for channel variables. This matches how we
consistently use sdi, devc, and so on all over the code-base.

This fixes parts of bug #259.
2014-03-25 20:58:54 +01:00
Matthias Heidbrink e83437ae20 serial-dmm: Implemented support for Voltcraft M-3650CR (driver voltcraft-m3650cr). 2014-03-24 22:57:27 +01:00
Matthias Heidbrink 1656e47def serial-dmm: Implemented support for Voltcraft ME-42 (driver voltcraft-me42). 2014-03-24 17:42:52 +01:00
Uwe Hermann 2710cb53fd serial-dmm: Support the Tenma 72-7745 via UT-D02 cable.
(it was already supported in uni-t-dmm via UT-D04 cable)
2014-01-06 20:30:56 +01:00
Uwe Hermann d9e79c5122 Add support for the Tenma 72-7750 (UNI-T UT60G rebadge). 2014-01-06 20:30:35 +01:00
Uwe Hermann 4104ef810e Add initial support for the UNI-T UT60G. 2014-01-06 19:06:51 +01:00
Uwe Hermann d327972b97 Add initial support for the V&A VA40B multimeter. 2014-01-02 01:46:15 +01:00
Uwe Hermann 7cb69b1870 Add support for the UNI-T UT61B multimeter. 2014-01-01 15:28:44 +01:00
Aurelien Jacobs d97824e52e switch the UNI-T UT61E driver to the new es519xx parser 2013-12-29 18:46:08 +01:00
Uwe Hermann 5f985df23c Add support for the UNI-T UT61C multimeter. 2013-12-29 17:35:51 +01:00
Matthias Heidbrink 825da8b20f serial-dmm: Add BBC Goerz Metrawatt M2110 DMM driver. 2013-12-19 00:40:31 +01:00
Uwe Hermann 66a4357667 serial-dmm: No error message upon 0 new bytes. 2013-12-01 19:30:35 +01:00
Uwe Hermann 88f544f27e Add support for the Metex M-4650CR.
(the Voltcraft M-4650CR is a rebadged Metex M-4650CR)
2013-10-30 14:44:44 +01:00
Uwe Hermann 2b83d7fee1 Add support for the Voltcraft M-4650CR. 2013-10-30 14:44:44 +01:00
Aurelien Jacobs df6b0f99af ISO-TECH IDM103N: remove the useless -ser postfix 2013-10-13 14:54:54 +02:00
Aurelien Jacobs de737bfc11 add ISO-TECH IDM103N serial-dmm driver 2013-10-07 00:36:18 +02:00
Uwe Hermann 2b691be806 serial-dmm/uni-t-dmm: Drop Tecpel DMM-8060.
The Tecpel DMM-8060 was added since we assumed it would be a rebadged
Voltcraft VC-820 (since we know the Tecpel DMM-8061 is a rebadged VC-840).

However, according to the vendor webpage it doesn't have PC connectivity
at all, so drop it for now (until someone can confirm that it does or does
not actually have RS232/USB connectivity).
2013-07-18 12:43:07 +02:00
Florian Knodt a7a163a795 Support for UNI-T UT60A/E multimeters via RS232 or USB 2013-07-09 22:57:55 +02:00
Uwe Hermann 6045b91aa4 serial-dmm: Add support for the Voltcraft VC-830. 2013-06-23 10:23:21 +02:00
Florian Steinhardt 5f2a4aff4b added Voltcraft M-3650D Multimeter 2013-06-14 01:03:29 +02:00
Uwe Hermann c2fa697afa serial-dmm: Add Tecpel DMM-8060 support. 2013-05-01 03:16:47 +02:00
Uwe Hermann b38e08fbb7 serial-dmm: Add Tecpel DMM-8061 support. 2013-05-01 03:13:43 +02:00
Uwe Hermann 2451a20ff5 fs9721: Factor out common code from serial-dmm.
These functions are FS9721 specific (and DMM specific), and can be used
from various drivers (e.g. serial-dmm or uni-t-dmm or possibly others).
2013-05-01 02:16:55 +02:00
Uwe Hermann 4853559466 uni-t-dmm/serial-dmm: Handle Voltcraft VC-840 temperature. 2013-05-01 01:58:42 +02:00
Uwe Hermann ae3a59de62 serial-dmm: Add support for the UNI-T UT61D.
This DMM is already supported via the uni-t-dmm driver when using the
USB/HID cable. The serial-dmm support makes it usable with the RS232
cable too.
2013-04-30 20:22:17 +02:00
Uwe Hermann 50985c2019 GPL headers: Use correct project name. 2013-04-23 22:24:30 +02:00
Uwe Hermann 1e1bfcd0fe serial-dmm: Use sr_dev_inst to store connection handle. 2013-04-23 20:55:04 +02:00
Alexandru Gagniuc 3864648bb6 serial-dmm: Add support for RadioShack 22-805
Protocol-wise, this is identical to the 22-168, except that it communicates at
600 baud instead of 1200 baud.
2013-03-20 20:36:56 -05:00
Uwe Hermann 7c8a9e1e0f serial-dmm: Drop unneeded g_try_malloc0(). 2013-02-02 12:34:25 +01:00
Bert Vermeulen 69e19dd769 Always interleave analog data with all enabled probes.
The new "probes" field in sr_datafeed_analog contains a copy
of all enabled struct sr_probe.
2013-01-23 03:40:44 +01:00
Uwe Hermann 986fde755d serial-dmm: Add UNI-T UT61E support (UT-D02 cable). 2013-01-03 01:13:57 +01:00
Uwe Hermann 1476661970 serial-dmm: Rename VOLTCRAFT_VC820 to VOLTCRAFT_VC820_SER.
This matches the _ser suffix of the other functions/variables for this
device ("ser" denotes that it is used with the serial UNI-T UT-D02 cable
as opposed the USB/HID based cables which are handled by the uni-t-dmm driver).

But more importantly, the _SER suffix for the enum value will prevent
name clashes later, when the uni-t-dmm driver gets a VOLTCRAFT_VC820 enum.

Do the same for VOLTCRAFT_VC840.
2012-12-26 02:11:00 +01:00
Uwe Hermann 35e199da50 Fix limit_samples check in various drivers.
Check whether a sample limit was actually set (> 0) before checking if
that sample limit is reached. This also fixes continuous acquisition mode
for drivers which have that.
2012-12-26 02:11:00 +01:00
Alexandru Gagniuc f9b9bd632f serial-dmm: Handle time-limited acquisition
Implement SR_HWCAP_LIMIT_MSEC capability, to allow acquisition to automatically
stop after a specified amount of time.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-25 23:55:42 +01:00
Alexandru Gagniuc d55c89f523 serial-dmm: Properly handle continuous mode
serial-dmm does not check if a sample limit is actually in place before deciding
to stop acquisition. Since the sample limit is set at 0 by default, operating
in continuous mode will cause acquisition to stop before even sending the first
sample.

Check to make sure we actually are in a sample-limited mode before stopping for
this reason.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-23 16:55:10 +01:00
Uwe Hermann 54d1122187 serial-dmm: Add Voltcraft VC-840 (UT-D02) support.
This works with the UNI-T UT-D02 (RS232) cable. For the USB/HID
based cable (UNI-T UT-D04), the uni-t-dmm driver must be used.

Note: This is untested, but should work just fine for all settings, with
the possible exception of temperature (testers needed!)
2012-12-17 14:21:12 +01:00
Uwe Hermann 40830061eb serial-dmm: Add Voltcraft VC-820 (UT-D02) support.
This works with the UNI-T UT-D02 (RS232) cable. For the USB/HID
based cable (UNI-T UT-D04), the uni-t-dmm driver must be used.
2012-12-17 14:21:12 +01:00
Uwe Hermann 22f5419235 serial-dmm: Cosmetics, documentation fixes. 2012-12-17 14:21:12 +01:00
Alexandru Gagniuc e7ed87a469 serial-dmm: Use dummy info struct for rs9lcd parser
The rs9lcd parser, which is used for the RadioShack 22-812 does not use its
*info parameter, and therefore did not have a rs9lcd_info struct declared.

With recent re-factoring of the receive data callbacks, it became necessary to
pass a struct pointer. This made the RECV_DATA macro look like:

- RECV_DATA(RADIOSHACK_22_812, metex14)

giving the wrong impression that the RadioShack 22-182 uses the
metex14 protocol, which is not the case.

Create a dummy rs9lcd_info struct, and correctly identify the parser
as rs9lcd in the RECV_DATA macro:

+ RECV_DATA(RADIOSHACK_22_812, rs9lcd)

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-13 23:16:34 +01:00
Uwe Hermann dccfe01586 serial-dmm: Use a macro for receive_data() wrappers. 2012-12-13 01:34:21 +01:00
Alexandru Gagniuc 21829e6708 radioshack-dmm: Integrate into serial-dmm
Use the infrastructure of serial-dmm to handle the RadioShack 22-812,
and completely remove radioshack-dmm.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-02 22:22:07 +01:00
Alexandru Gagniuc d5ce233fe1 serial-dmm: Add RadioShack 22-168 support.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-02 17:38:05 +01:00
Uwe Hermann d4bd66a0c7 serial-dmm: Add PCE PCE-DM32 support. 2012-12-02 14:28:29 +01:00
Uwe Hermann a376ffea49 serial-dmm: Add PeakTech 4370 support. 2012-12-02 14:22:51 +01:00
Uwe Hermann a53da08254 serial-dmm: Add Metex M-3640D support. 2012-12-02 14:22:51 +01:00
Uwe Hermann 6dca2f16ee serial-dmm: Add V&A VA18B support. 2012-12-02 14:22:51 +01:00
Uwe Hermann 5887c9cc1a serial-dmm: Add MASTECH MAS345 support. 2012-12-02 14:22:51 +01:00
Uwe Hermann f0ac4929d3 serial-dmm: Add PeakTech 3410 support. 2012-12-02 14:22:51 +01:00
Uwe Hermann ce3777ada9 serial-dmm: Add Metex ME-31 support. 2012-12-02 14:22:46 +01:00
Uwe Hermann f086b83011 serial-dmm: Add Digitek DT4000ZC support. 2012-12-02 14:21:19 +01:00