libsigrok/src/hardware/fluke-dmm/api.c

285 lines
7.0 KiB
C

/*
* This file is part of the libsigrok project.
*
* Copyright (C) 2012 Bert Vermeulen <bert@biot.com>
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include <config.h>
#include <glib.h>
#include <sys/types.h>
#include <sys/stat.h>
#include <fcntl.h>
#include <string.h>
#include <libsigrok/libsigrok.h>
#include "libsigrok-internal.h"
#include "fluke-dmm.h"
static const uint32_t scanopts[] = {
SR_CONF_CONN,
SR_CONF_SERIALCOMM,
};
static const uint32_t devopts[] = {
SR_CONF_MULTIMETER,
SR_CONF_CONTINUOUS,
SR_CONF_LIMIT_SAMPLES | SR_CONF_SET,
SR_CONF_LIMIT_MSEC | SR_CONF_SET,
};
static const char *scan_conn[] = {
/* 287/289 */
"115200/8n1",
/* 187/189 */
"9600/8n1",
/* Scopemeter 190 series */
"1200/8n1",
NULL
};
static const struct flukedmm_profile supported_flukedmm[] = {
{ FLUKE_187, "187", 100, 1000 },
{ FLUKE_189, "189", 100, 1000 },
{ FLUKE_287, "287", 100, 1000 },
{ FLUKE_190, "199B", 1000, 3500 },
{ FLUKE_289, "289", 100, 1000 },
};
static GSList *fluke_scan(struct sr_dev_driver *di, const char *conn,
const char *serialcomm)
{
struct sr_dev_inst *sdi;
struct drv_context *drvc;
struct dev_context *devc;
struct sr_serial_dev_inst *serial;
GSList *devices;
int retry, len, i, s;
char buf[128], *b, **tokens;
serial = sr_serial_dev_inst_new(conn, serialcomm);
if (serial_open(serial, SERIAL_RDWR) != SR_OK)
return NULL;
drvc = di->context;
b = buf;
retry = 0;
devices = NULL;
/* We'll try the discovery sequence three times in case the device
* is not in an idle state when we send ID. */
while (!devices && retry < 3) {
retry++;
serial_flush(serial);
if (serial_write_blocking(serial, "ID\r", 3, SERIAL_WRITE_TIMEOUT_MS) < 0) {
sr_err("Unable to send ID string");
continue;
}
/* Response is first a CMD_ACK byte (ASCII '0' for OK,
* or '1' to signify an error. */
len = 128;
serial_readline(serial, &b, &len, 150);
if (len != 1)
continue;
if (buf[0] != '0')
continue;
/* If CMD_ACK was OK, ID string follows. */
len = 128;
serial_readline(serial, &b, &len, 850);
if (len < 10)
continue;
if (strcspn(buf, ",") < 15)
/* Looks like it's comma-separated. */
tokens = g_strsplit(buf, ",", 3);
else
/* Fluke 199B, at least, uses semicolon. */
tokens = g_strsplit(buf, ";", 3);
if (!strncmp("FLUKE", tokens[0], 5)
&& tokens[1] && tokens[2]) {
for (i = 0; supported_flukedmm[i].model; i++) {
if (strcmp(supported_flukedmm[i].modelname, tokens[0] + 6))
continue;
/* Skip leading spaces in version number. */
for (s = 0; tokens[1][s] == ' '; s++);
sdi = g_malloc0(sizeof(struct sr_dev_inst));
sdi->status = SR_ST_INACTIVE;
sdi->vendor = g_strdup("Fluke");
sdi->model = g_strdup(tokens[0] + 6);
sdi->version = g_strdup(tokens[1] + s);
devc = g_malloc0(sizeof(struct dev_context));
devc->profile = &supported_flukedmm[i];
sdi->inst_type = SR_INST_SERIAL;
sdi->conn = serial;
sdi->priv = devc;
sdi->driver = di;
sr_channel_new(sdi, 0, SR_CHANNEL_ANALOG, TRUE, "P1");
drvc->instances = g_slist_append(drvc->instances, sdi);
devices = g_slist_append(devices, sdi);
break;
}
}
g_strfreev(tokens);
if (devices)
/* Found one. */
break;
}
serial_close(serial);
if (!devices)
sr_serial_dev_inst_free(serial);
return devices;
}
static GSList *scan(struct sr_dev_driver *di, GSList *options)
{
struct sr_config *src;
GSList *l, *devices;
int i;
const char *conn, *serialcomm;
conn = serialcomm = NULL;
for (l = options; l; l = l->next) {
src = l->data;
switch (src->key) {
case SR_CONF_CONN:
conn = g_variant_get_string(src->data, NULL);
break;
case SR_CONF_SERIALCOMM:
serialcomm = g_variant_get_string(src->data, NULL);
break;
}
}
if (!conn)
return NULL;
devices = NULL;
if (serialcomm) {
/* Use the provided comm specs. */
devices = fluke_scan(di, conn, serialcomm);
} else {
for (i = 0; scan_conn[i]; i++) {
if ((devices = fluke_scan(di, conn, scan_conn[i])))
break;
/* The Scopemeter 199B, at least, requires this
* after all the 115k/9.6k confusion. */
g_usleep(5 * 1000);
}
}
return devices;
}
static int config_set(uint32_t key, GVariant *data, const struct sr_dev_inst *sdi,
const struct sr_channel_group *cg)
{
struct dev_context *devc;
(void)cg;
if (sdi->status != SR_ST_ACTIVE)
return SR_ERR_DEV_CLOSED;
devc = sdi->priv;
switch (key) {
case SR_CONF_LIMIT_MSEC:
/* TODO: not yet implemented */
devc->limit_msec = g_variant_get_uint64(data);
break;
case SR_CONF_LIMIT_SAMPLES:
devc->limit_samples = g_variant_get_uint64(data);
break;
default:
return SR_ERR_NA;
}
return SR_OK;
}
static int config_list(uint32_t key, GVariant **data, const struct sr_dev_inst *sdi,
const struct sr_channel_group *cg)
{
(void)sdi;
(void)cg;
switch (key) {
case SR_CONF_SCAN_OPTIONS:
*data = g_variant_new_fixed_array(G_VARIANT_TYPE_UINT32,
scanopts, ARRAY_SIZE(scanopts), sizeof(uint32_t));
break;
case SR_CONF_DEVICE_OPTIONS:
*data = g_variant_new_fixed_array(G_VARIANT_TYPE_UINT32,
devopts, ARRAY_SIZE(devopts), sizeof(uint32_t));
break;
default:
return SR_ERR_NA;
}
return SR_OK;
}
static int dev_acquisition_start(const struct sr_dev_inst *sdi)
{
struct dev_context *devc;
struct sr_serial_dev_inst *serial;
if (sdi->status != SR_ST_ACTIVE)
return SR_ERR_DEV_CLOSED;
devc = sdi->priv;
std_session_send_df_header(sdi, LOG_PREFIX);
/* Poll every 100ms, or whenever some data comes in. */
serial = sdi->conn;
serial_source_add(sdi->session, serial, G_IO_IN, 50,
fluke_receive_data, (void *)sdi);
if (serial_write_blocking(serial, "QM\r", 3, SERIAL_WRITE_TIMEOUT_MS) < 0) {
sr_err("Unable to send QM.");
return SR_ERR;
}
devc->cmd_sent_at = g_get_monotonic_time() / 1000;
devc->expect_response = TRUE;
return SR_OK;
}
static int dev_acquisition_stop(struct sr_dev_inst *sdi)
{
return std_serial_dev_acquisition_stop(sdi, std_serial_dev_close,
sdi->conn, LOG_PREFIX);
}
SR_PRIV struct sr_dev_driver flukedmm_driver_info = {
.name = "fluke-dmm",
.longname = "Fluke 18x/28x series DMMs",
.api_version = 1,
.init = std_init,
.cleanup = std_cleanup,
.scan = scan,
.dev_list = std_dev_list,
.dev_clear = NULL,
.config_get = NULL,
.config_set = config_set,
.config_list = config_list,
.dev_open = std_serial_dev_open,
.dev_close = std_serial_dev_close,
.dev_acquisition_start = dev_acquisition_start,
.dev_acquisition_stop = dev_acquisition_stop,
.context = NULL,
};