2016-08-16 10:56:20 +00:00
|
|
|
|
/*
|
|
|
|
|
* This program source code file is part of KiCad, a free EDA CAD application.
|
|
|
|
|
*
|
|
|
|
|
* Copyright (C) 2016 Jean-Pierre Charras, jp.charras at wanadoo.fr
|
|
|
|
|
* Copyright (C) 2016 KiCad Developers, see AUTHORS.txt for contributors.
|
|
|
|
|
*
|
|
|
|
|
* This program is free software; you can redistribute it and/or
|
|
|
|
|
* modify it under the terms of the GNU General Public License
|
|
|
|
|
* as published by the Free Software Foundation; either version 2
|
|
|
|
|
* of the License, or (at your option) any later version.
|
|
|
|
|
*
|
|
|
|
|
* This program is distributed in the hope that it will be useful,
|
|
|
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
|
* GNU General Public License for more details.
|
|
|
|
|
*
|
|
|
|
|
* You should have received a copy of the GNU General Public License
|
|
|
|
|
* along with this program; if not, you may find one here:
|
|
|
|
|
* http://www.gnu.org/licenses/old-licenses/gpl-2.0.html
|
|
|
|
|
* or you may search the http://www.gnu.org website for the version 2 license,
|
|
|
|
|
* or you may write to the Free Software Foundation, Inc.,
|
|
|
|
|
* 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA
|
|
|
|
|
*/
|
|
|
|
|
|
|
|
|
|
#ifndef GBR_NETLIST_METADATA_H
|
|
|
|
|
#define GBR_NETLIST_METADATA_H
|
|
|
|
|
|
2019-09-15 15:08:57 +00:00
|
|
|
|
/** this class handle info which can be added in a gerber P&P file as attribute
|
|
|
|
|
* of a component
|
|
|
|
|
* Only applicable to objects having the TA.AperFunction attribute "ComponentMain"
|
|
|
|
|
* There are specific attributes defined attached to the component by the %TO command
|
|
|
|
|
* %TO.CRot,<angle> The rotation angle of the component.
|
|
|
|
|
* The rotation angle is consistent with the one for graphics objects.
|
|
|
|
|
* Positive rotation is counter- clockwise as viewed from the top side, even if
|
|
|
|
|
* the component is on the board side.
|
|
|
|
|
* The base orientation of component <EFBFBD> no rotation - on the top side is as in IPC-7351.
|
|
|
|
|
* Components on the bottom side are of course mirrored.
|
|
|
|
|
* The base orientation on the bottom side is the one on the top side
|
|
|
|
|
* mirrored around the X axis.
|
|
|
|
|
* %TO.CMfr,<string> Manufacturer
|
|
|
|
|
* %TO.CMPN,<string> Manufacturer part number
|
|
|
|
|
* %TO.Cpkg,<string> Package, as per IPC-7351
|
2019-10-06 11:39:50 +00:00
|
|
|
|
* %TO.CVal,<string> Value, a string. E.g. 220nF
|
|
|
|
|
* %TO.CMnt,<string> Mount type: (SMD|BGA|TH|Other)
|
2019-09-15 15:08:57 +00:00
|
|
|
|
* %TO.CFtp,<string> Footprint name, a string. E.g. LQFP-100_14x14mm_P0.5mm
|
|
|
|
|
This is the footprint name coming from the CAD tool libraries.
|
2019-10-06 11:39:50 +00:00
|
|
|
|
* %TO.CPgN,<string> Package name, like the JEDEC JEP95 standard.
|
|
|
|
|
* %TO.CPgD,<string> Package description.
|
2019-09-15 15:08:57 +00:00
|
|
|
|
* %TO.CHgt,<string> Height, a decimal, in the unit of the file.
|
2019-10-06 11:39:50 +00:00
|
|
|
|
* %TO.CLbN,<string> Library name.
|
|
|
|
|
* %TO.CLbD,<string> Library description.
|
|
|
|
|
* %TO.Sup,<SN>,<SPN> SN is a field with the supppier name.
|
|
|
|
|
* SPN is a field with the supppier part name
|
2019-09-15 15:08:57 +00:00
|
|
|
|
*/
|
|
|
|
|
class GBR_CMP_PNP_METADATA
|
|
|
|
|
{
|
|
|
|
|
public:
|
|
|
|
|
enum MOUNT_TYPE
|
|
|
|
|
{
|
|
|
|
|
MOUNT_TYPE_UNSPECIFIED,
|
|
|
|
|
MOUNT_TYPE_SMD,
|
|
|
|
|
MOUNT_TYPE_BGA,
|
|
|
|
|
MOUNT_TYPE_TH
|
|
|
|
|
};
|
|
|
|
|
|
|
|
|
|
double m_Orientation; // orientation in degree
|
|
|
|
|
wxString m_Manufacturer; // Manufacturer name
|
|
|
|
|
wxString m_MPN; // Manufacturer part number
|
|
|
|
|
wxString m_Package; // Package, as per IPC-7351
|
|
|
|
|
wxString m_Footprint; // Footprint name, from library
|
2019-10-06 11:39:50 +00:00
|
|
|
|
wxString m_LibraryName; // Library name, containing the footprint
|
|
|
|
|
wxString m_LibraryDescr; // Library description
|
2019-09-15 15:08:57 +00:00
|
|
|
|
wxString m_Value; // Component value
|
|
|
|
|
MOUNT_TYPE m_MountType; // SMD|TH|Other
|
|
|
|
|
|
|
|
|
|
GBR_CMP_PNP_METADATA() :
|
|
|
|
|
m_Orientation( 0.0 ), m_MountType( MOUNT_TYPE_UNSPECIFIED )
|
|
|
|
|
{}
|
|
|
|
|
|
|
|
|
|
void ClearData(); // Clear all strings
|
|
|
|
|
/**
|
|
|
|
|
* @return a string containing the formated metadata in X2 syntax.
|
|
|
|
|
* one line by non empty data
|
|
|
|
|
* the orientation is always generated
|
|
|
|
|
*/
|
|
|
|
|
wxString FormatCmpPnPMetadata();
|
|
|
|
|
};
|
|
|
|
|
|
2016-08-16 10:56:20 +00:00
|
|
|
|
|
2017-07-02 14:41:31 +00:00
|
|
|
|
/** this class handle info which can be added in a gerber file as attribute
|
2019-09-15 15:08:57 +00:00
|
|
|
|
* of an object
|
2017-07-02 14:41:31 +00:00
|
|
|
|
* the GBR_INFO_TYPE types can be OR'ed to add 2 (or more) attributes
|
|
|
|
|
* There are only 3 net attributes defined attached to an object by the %TO command
|
|
|
|
|
* %TO.P
|
|
|
|
|
* %TO.N
|
|
|
|
|
* %TO.C
|
|
|
|
|
* the .P attribute can be used only for flashed pads (using the D03 command)
|
|
|
|
|
* and only for external copper layers, if the component is on a external copper layer
|
|
|
|
|
* for other copper layer items (pads on internal layers, tracks ... ), only .N and .C
|
|
|
|
|
* can be used
|
|
|
|
|
*/
|
2016-08-16 10:56:20 +00:00
|
|
|
|
class GBR_NETLIST_METADATA
|
|
|
|
|
{
|
|
|
|
|
public:
|
|
|
|
|
// This enum enables the different net attributes attache to the object
|
|
|
|
|
// the values can be ORed for items which can have more than one attribute
|
|
|
|
|
// (A flashed pad has all allowed attributes)
|
|
|
|
|
enum GBR_NETINFO_TYPE
|
|
|
|
|
{
|
|
|
|
|
GBR_NETINFO_UNSPECIFIED, ///< idle command (no command)
|
|
|
|
|
GBR_NETINFO_PAD = 1, ///< print info associated to a flashed pad (TO.P attribute)
|
|
|
|
|
GBR_NETINFO_NET = 2, ///< print info associated to a net (TO.N attribute)
|
|
|
|
|
GBR_NETINFO_CMP = 4 ///< print info associated to a component (TO.C attribute)
|
|
|
|
|
};
|
|
|
|
|
|
|
|
|
|
// these members are used in the %TO object attributes command.
|
2016-08-19 07:45:59 +00:00
|
|
|
|
int m_NetAttribType; ///< the type of net info
|
2016-08-16 10:56:20 +00:00
|
|
|
|
///< (used to define the gerber string to create)
|
2016-08-19 07:45:59 +00:00
|
|
|
|
bool m_NotInNet; ///< true if a pad of a footprint cannot be connected
|
|
|
|
|
///< (for instance a mechanical NPTH, ot a not named pad)
|
|
|
|
|
///< in this case the pad net name is empty in gerber file
|
2016-08-16 10:56:20 +00:00
|
|
|
|
wxString m_Padname; ///< for a flashed pad: the pad name ((TO.P attribute)
|
|
|
|
|
wxString m_Cmpref; ///< the component reference parent of the data
|
|
|
|
|
wxString m_Netname; ///< for items associated to a net: the netname
|
|
|
|
|
|
2019-09-18 09:48:49 +00:00
|
|
|
|
wxString m_ExtraData; ///< a string to print after %TO object attributes, if not empty
|
|
|
|
|
///< it is printed "as this"
|
2019-10-17 10:41:42 +00:00
|
|
|
|
/** If true, do not clear all attributes when a atribute has changed
|
|
|
|
|
* Usefull when some attributes need to be persistant.
|
|
|
|
|
* If false, attributes will be cleared if only one attribute cleared
|
|
|
|
|
* This is a more secure way to set attributes, when all attribute changess are not safely managed
|
|
|
|
|
*/
|
|
|
|
|
bool m_TryKeepPreviousAttributes;
|
2019-09-18 09:48:49 +00:00
|
|
|
|
|
|
|
|
|
|
2019-10-17 10:41:42 +00:00
|
|
|
|
GBR_NETLIST_METADATA(): m_NetAttribType( GBR_NETINFO_UNSPECIFIED ),
|
|
|
|
|
m_NotInNet( false ), m_TryKeepPreviousAttributes( false )
|
2016-08-16 10:56:20 +00:00
|
|
|
|
{
|
|
|
|
|
}
|
|
|
|
|
|
2019-09-18 09:48:49 +00:00
|
|
|
|
/** Clear the extra data string printed at end of net attributes
|
|
|
|
|
*/
|
|
|
|
|
void ClearExtraData()
|
|
|
|
|
{
|
|
|
|
|
m_ExtraData.Clear();
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
/** Set the extra data string printed at end of net attributes
|
|
|
|
|
*/
|
|
|
|
|
void SetExtraData( const wxString& aExtraData)
|
|
|
|
|
{
|
|
|
|
|
m_ExtraData = aExtraData;
|
|
|
|
|
}
|
|
|
|
|
|
2016-08-16 10:56:20 +00:00
|
|
|
|
/**
|
|
|
|
|
* remove the net attribute specified by aName
|
|
|
|
|
* If aName == NULL or empty, remove all attributes
|
|
|
|
|
* @param aName is the name (.CN, .P .N or .C) of the attribute to remove
|
|
|
|
|
*/
|
|
|
|
|
void ClearAttribute( const wxString* aName )
|
|
|
|
|
{
|
|
|
|
|
if( m_NetAttribType == GBR_NETINFO_UNSPECIFIED )
|
|
|
|
|
{
|
|
|
|
|
m_Padname.clear();
|
|
|
|
|
m_Cmpref.clear();
|
|
|
|
|
m_Netname.clear();
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if( !aName || aName->IsEmpty() || *aName == ".CN" )
|
|
|
|
|
{
|
|
|
|
|
m_NetAttribType = GBR_NETINFO_UNSPECIFIED;
|
|
|
|
|
m_Padname.clear();
|
|
|
|
|
m_Cmpref.clear();
|
|
|
|
|
m_Netname.clear();
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if( *aName == ".C" )
|
|
|
|
|
{
|
|
|
|
|
m_NetAttribType &= ~GBR_NETINFO_CMP;
|
|
|
|
|
m_Cmpref.clear();
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if( *aName == ".N" )
|
|
|
|
|
{
|
|
|
|
|
m_NetAttribType &= ~GBR_NETINFO_NET;
|
|
|
|
|
m_Netname.clear();
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if( *aName == ".P" )
|
|
|
|
|
{
|
|
|
|
|
m_NetAttribType &= ~GBR_NETINFO_PAD;
|
2017-07-02 14:41:31 +00:00
|
|
|
|
m_Padname.clear();
|
2016-08-16 10:56:20 +00:00
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
};
|
|
|
|
|
|
|
|
|
|
// Flashed pads use the full attribute set: this is a helper for flashed pads
|
|
|
|
|
#define GBR_NETINFO_ALL (GBR_NETLIST_METADATA::GBR_NETINFO_PAD\
|
|
|
|
|
| GBR_NETLIST_METADATA::GBR_NETINFO_NET\
|
|
|
|
|
| GBR_NETLIST_METADATA::GBR_NETINFO_CMP )
|
|
|
|
|
|
|
|
|
|
#endif // GBR_NETLIST_METADATA_H
|