More spelling and grammar fixes
This commit is contained in:
parent
435e60d0e5
commit
6c9e716573
|
@ -53,7 +53,7 @@ PANEL_ELECTRICAL_SPACING_IEC60664_BASE::PANEL_ELECTRICAL_SPACING_IEC60664_BASE(
|
|||
|
||||
m_staticText52111 = new wxStaticText( sbSizerTop->GetStaticBox(), wxID_ANY, _("Overvoltage category:"), wxDefaultPosition, wxDefaultSize, 0 );
|
||||
m_staticText52111->Wrap( -1 );
|
||||
m_staticText52111->SetToolTip( _("OVC I: Equipments with no direct connection to mains supply\n\nOVC II: Energy-consuming equipment to be supplied from the fixed installation. (eg: appliances, portable tools, household loads). OVCIII applies if there are reliability and avaibility requirements\n\nOVC III : Equipements in fixed installation with reliability and avaibility requirements. (eg: electrical switches, equipment for industrial use)\n\nOVC IV: Equipments at the origin of the installation (eg: electricity meters, primary overcurrent protection devices)") );
|
||||
m_staticText52111->SetToolTip( _("OVC I: Equipment with no direct connection to mains supply\n\nOVC II: Energy-consuming equipment to be supplied from the fixed installation. (eg: appliances, portable tools, household loads). OVCIII applies if there are reliability and avaibility requirements\n\nOVC III : Equipment in fixed installations with reliability and avaibility requirements. (eg: electrical switches, equipment for industrial use)\n\nOVC IV: Equipment at the origin of the installation (eg: electricity meters, primary overcurrent protection devices)") );
|
||||
|
||||
fgSizer111->Add( m_staticText52111, 0, wxALIGN_CENTER_VERTICAL|wxBOTTOM|wxRIGHT|wxLEFT, 5 );
|
||||
|
||||
|
@ -82,7 +82,7 @@ PANEL_ELECTRICAL_SPACING_IEC60664_BASE::PANEL_ELECTRICAL_SPACING_IEC60664_BASE(
|
|||
|
||||
m_staticText111111 = new wxStaticText( sbSizerTop->GetStaticBox(), wxID_ANY, _("Impulse voltage:"), wxDefaultPosition, wxDefaultSize, 0 );
|
||||
m_staticText111111->Wrap( -1 );
|
||||
m_staticText111111->SetToolTip( _("Given the rated voltage and the overvoltage category, a device should withstand this value whithout a breakdown of insulation. This impulse voltage is a standard 1.2/50µs wave") );
|
||||
m_staticText111111->SetToolTip( _("Given the rated voltage and the overvoltage category, a device should withstand this value without a breakdown of insulation. This impulse voltage is a standard 1.2/50µs wave") );
|
||||
|
||||
fgSizerTopRight->Add( m_staticText111111, 0, wxALIGN_CENTER_VERTICAL|wxALL, 5 );
|
||||
|
||||
|
|
|
@ -458,7 +458,7 @@
|
|||
<property name="style"></property>
|
||||
<property name="subclass">; ; forward_declare</property>
|
||||
<property name="toolbar_pane">0</property>
|
||||
<property name="tooltip">OVC I: Equipments with no direct connection to mains supply

OVC II: Energy-consuming equipment to be supplied from the fixed installation. (eg: appliances, portable tools, household loads). OVCIII applies if there are reliability and avaibility requirements

OVC III : Equipements in fixed installation with reliability and avaibility requirements. (eg: electrical switches, equipment for industrial use)

OVC IV: Equipments at the origin of the installation (eg: electricity meters, primary overcurrent protection devices)</property>
|
||||
<property name="tooltip">OVC I: Equipment with no direct connection to mains supply

OVC II: Energy-consuming equipment to be supplied from the fixed installation. (eg: appliances, portable tools, household loads). OVCIII applies if there are reliability and avaibility requirements

OVC III : Equipment in fixed installations with reliability and avaibility requirements. (eg: electrical switches, equipment for industrial use)

OVC IV: Equipment at the origin of the installation (eg: electricity meters, primary overcurrent protection devices)</property>
|
||||
<property name="window_extra_style"></property>
|
||||
<property name="window_name"></property>
|
||||
<property name="window_style"></property>
|
||||
|
@ -623,7 +623,7 @@
|
|||
<property name="style"></property>
|
||||
<property name="subclass">; ; forward_declare</property>
|
||||
<property name="toolbar_pane">0</property>
|
||||
<property name="tooltip">Given the rated voltage and the overvoltage category, a device should withstand this value whithout a breakdown of insulation. This impulse voltage is a standard 1.2/50µs wave</property>
|
||||
<property name="tooltip">Given the rated voltage and the overvoltage category, a device should withstand this value without a breakdown of insulation. This impulse voltage is a standard 1.2/50µs wave</property>
|
||||
<property name="window_extra_style"></property>
|
||||
<property name="window_name"></property>
|
||||
<property name="window_style"></property>
|
||||
|
|
Loading…