Negative clearance means test won't run, not rule won't match.
Fixes https://gitlab.com/kicad/code/kicad/issues/13947
This commit is contained in:
parent
245ce7259c
commit
6d22b8c6ed
|
@ -881,15 +881,6 @@ DRC_CONSTRAINT DRC_ENGINE::EvalRules( DRC_CONSTRAINT_T aConstraintType, const BO
|
||||||
REPORT( wxString::Format( _( "Checking %s clearance: %s." ),
|
REPORT( wxString::Format( _( "Checking %s clearance: %s." ),
|
||||||
EscapeHTML( c->constraint.GetName() ),
|
EscapeHTML( c->constraint.GetName() ),
|
||||||
MessageTextFromValue( c->constraint.m_Value.Min() ) ) )
|
MessageTextFromValue( c->constraint.m_Value.Min() ) ) )
|
||||||
|
|
||||||
if( c->constraint.GetValue().Min() < 0 )
|
|
||||||
{
|
|
||||||
// JEY TODO: translate for 8.0....
|
|
||||||
REPORT( implicit ? wxS( "Negative clearance specified; constraint ignored." )
|
|
||||||
: wxS( "Negative clearance specified; rule ignored." ) )
|
|
||||||
return true;
|
|
||||||
}
|
|
||||||
|
|
||||||
break;
|
break;
|
||||||
|
|
||||||
case DIFF_PAIR_MAX_UNCOUPLED_CONSTRAINT:
|
case DIFF_PAIR_MAX_UNCOUPLED_CONSTRAINT:
|
||||||
|
|
|
@ -774,6 +774,9 @@ int BOARD_INSPECTION_TOOL::InspectClearance( const TOOL_EVENT& aEvent )
|
||||||
r->Report( "" );
|
r->Report( "" );
|
||||||
r->Report( wxString::Format( _( "Resolved clearance: %s." ),
|
r->Report( wxString::Format( _( "Resolved clearance: %s." ),
|
||||||
m_frame->StringFromValue( clearance, true ) ) );
|
m_frame->StringFromValue( clearance, true ) ) );
|
||||||
|
|
||||||
|
if( clearance < 0 )
|
||||||
|
r->Report( wxS( "Negative clearance value; clearance will not be tested." ) );
|
||||||
}
|
}
|
||||||
|
|
||||||
r->Flush();
|
r->Flush();
|
||||||
|
|
Loading…
Reference in New Issue