The alias list now displays the user model (multiple aliases *of*
a root part, rather than a collection of names *including* the
root part). This simplified the error detection logic, fixing
the first bug in the bug report.
Updating the part in the library is now done uniformly on OK
(which was the second bug in the bug report).
Fixes: lp:1744656
* https://bugs.launchpad.net/kicad/+bug/1744656
At least on Linux, if a null icon is used as icon in Pin Type column, other icons are not
displayed. So the workaround is to use a neutral icon when a specific icon cannot be used
(i.e. when pins are grouped)
Fixes: lp:1559542
https://bugs.launchpad.net/kicad/+bug/1559542
Change the behavior of the remapping algorithm to remap even if a
project symbol library table exists in the project file in case a
previous attempt to remap failed. The existing symbol library table
is backed up to the back folder and rebuilt.
Fixes lp:1741983
https://bugs.launchpad.net/kicad/+bug/1741983
This is meant as a stopgap for 5.0, with plans to add proper scaled
icons in the 6.0 cycle. A function KiScaledBitmap() is added, which
works like KiBitmap() except it scales the bitmap according to the
calling window's font size. Controls have been added to all the main
applications to let the user select scaling manually (these were omitted
from smaller apps that didn't already have a place to put them).
In addition, in eeschema only, the pixel height of the system font is
shown in the options dialog for diagnostics. This is only for collecting
feedback before 5.0 release from users with different displays and will
be removed.
File names with spaces were causing invalid symbol names in both the
rescue library and the cache which would cause both libraries to fail
to load because library symbol names are not escaped so the spaces
tripped up the library parser. Replace the spaces in the file names
with hyphens and in both the rescuer and the remapping code so the
library nickname in the symbol library table does not contain spaces.
Update the symbol library table dialog to prevent users from defining
library nicknames with spaces. This is different than the footprint
library table which allows nicknames with spaces. This solution is
a temporary fix until the new symbol library and schematic file formats
are implemented.
Fix off by one row in illegal nickname error message in the symbol
library table editor.
Verify the library symbol of the field being edited still exists rather
than use an assertion because it is entirely feasible that the library
symbol or library containing this symbol has been deleted and will cause
a segfault. Unfortunately there is no way to determine if the symbol is
a power symbol or not so just set it as a regular symbol so the user can
still edit the schematic symbol field.
Fixes lp:1742111
https://bugs.launchpad.net/kicad/+bug/1742111
Calling wxListBox::SetSelection( wxNOT_FOUND ) changes the internal
state of the widget without the intended visual effect (show nothing
selected). It leads to a situation when the default choice is overridden
with wxNOT_FOUND, even though the list box shows a valid value.
As there is no point in calling wxListBox::SetSelection( wxNOT_FOUND ),
the confusing call has been removed.
Dialogs displaying a lot of scrollable data should use SetSizeInDU()
instead, as FinishDialogSettings() will set a minimum size equal to
whatever can contain all the data (making it overflow the screen for
large amounts).
- Add helper methods for DPI-independent sizes
- Make splitter sashes visible on macOS
- Remove SetSizeInChars() - wx has a built-in way that I missed
- DIALOG_CHOOSE_COMPONENT: DPI-indep splitter sizes
- DIALOG_RESCUE_EACH: DPI-indep default size and sensible HTML window
size
- COMPONENT_TREE: DPI-indep sizing
- DIALOG_FP_LIB_TABLE, DIALOG_SYMBOL_LIB_TABLE
Create separate folder in project path to backup files changed during
remapping.
Add time stamp to backup file names in case multiple remappings are
performed.
Add backup file information to report panel instead of using debug
trace messages.
Disable the remap button if the user does not have write privileges to
the current project path.
The Windows drive specifier C: was being interpreted as a valid URL by
wxURI which was performing a URL comparison instead of a file comparison
which always failed in LIB_TABLE_BASE::FindRowByURI(). Change test for
URI to search string for "://" to determine if the comparison should be
a URI (string) comparison or a file (wxFileName) comparison.
Don't run final rescue unless the user performs the remapping.
Improve dialog layout and fix UI policy issues with all of the dialog
boxes in the common, 3D viewer, CvPcb, and Eeschema code paths.
Updated the use of component to symbol.
Replace all instances of "component" and "part" with "symbol" when
referring to schematic and library symbols.
Replace all instances of "component" with "footprint" when referring to
board and library footprints.
Minor dialog layout fixes to some of the dialogs impacted by the UI
string changes.
The remapping utility would create a new project specific library when a
symbolic link pointed to a library already defined in the symbol library
table. Now the comparison checks to see if the library path and file
name are actually a symbolic link if the file names are not the same when
the symbol library table entry is a file name rather than a URL. URLs
are simple string comparisons.
Disable the remap button after the remapping completed.
Remove some commented out code from the edit symbol in schematic dialog.
Fixes lp:1738634
https://bugs.launchpad.net/kicad/+bug/1738634
If a schematic contains two symbols with the same name from different
libraries, the cache will contain the last symbol saved with that name.
Prepend the library nickname with the original schematic symbol library
nickname when saving the cache library to prevent name collisions.
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic
Make the user prompt an HTML control for improved layout.
Fix some column title sizing issues. This is not a complete fix but
it seems better than the default sizing done by wxWidgets.
Use symbol terminology instead of part and/or component.
Create trace string source files for a common place for them and their
Doxygen comments.
Don't back up schematic files unless the user requests a remap.
Back up all files that could be changed by a remap including the
schematic file(s), cache library, project file, and rescue library
files.
Use an HTML control instead of a static text control for improved layout
of the user remap prompt.
Improve the user prompt in the remap dialog to make it clear that changes
will be made to project files.
Remove the placeholders for the upcoming s-expression schematic and
symbol library file format plugin type. The lack of a valid plugin
implementation was causing an undefined plugin type string in the
plugin type selection cell when new rows were added to the table.
Fixes lp:1733116
https://bugs.launchpad.net/kicad/+bug/1733116
Do not attempt to normalize environment variables that are not valid
paths, paths that do not exist, or paths that the user does not have
read access to.
Fixes lp:1731655
https://bugs.launchpad.net/kicad/+bug/1731655
Dotted, dashed and dash-dot lines are provided in
HPGL, PDF, PS and SVG plot outputs along with line
width and color formatting.
DXF format does not currently provide any dashed
line functionality
A bug in HPGL plotted is corrected. Previous HPGL
dashed line commands were incorrect, plotting all
lines as solid.
The GTK+ file dialog is case sensitive however it does support regular
expressions. Most of the file dialog wildcards are lower case so only
files with the lower case extensions will show up in the file dialog.
This code adds a method to convert file extensions of any case to the
appropriate (sch -> [sS][cC][hH]) regular expression on GTK+ builds so
all file extension case combinations will show up in the file dialog.
A note to developers: make sure to add a file extension when setting
when setting the default file argument. If you do don't set an
extension, the GTK+ file dialog will happily append the regular
expression as the file extension which is surely not what you want.
There are still a few known places (mostly gerbview) where there are
some complex wildcard code that has not been converted.
Fixes lp:1720542
https://bugs.launchpad.net/kicad/+bug/1720542
A copy and paste error was causing to footprint library table file name
and path to be shown in the symbol library table edit dialog. Factor
out code in PROJECT::FootprintLibTblName() to PROJECT::libTableName()
to handle both symbol and footprint library table names and create a
new PROJECT::SymbolLibTableName() method to fix the path and file name
in the symbol library table edit dialog.
In the rare case when something goes wrong with the symbol library
table remapping, do not attempt to rescue symbols that are neither
in the cache nor in any of the libraries.
The legacy rescue library code overwrote the existing library so
previous rescues would get lost. If the rescue library exists,
copy it's contents into the new rescue library before adding the
new rescued symbols so no previously rescued symbols are lost.
Fix a null pointer bug in the symbol library editor when no symbol
is loaded.
Set LIB_ID item name to name passed to LIB_PART ctor.
Copy LIB_ID in LIB_PART copy ctor.
The old symbol library list save/load code does not get called in the
schematic project file configuration code. Use the LibNamesAndPaths
static function from the PART_LIBS object.
Bump schematic file version from 3 to 4 which represents the switch to
the library table symbol linking which is incompatible with all previous
versions.
Refresh the schematic after running remapping dialog manually.
Add missing CMP_TREE_NODE_LIB_ID type that was inadvertently deleted by
the symbol library table implementation that broke the preselected symbol
tree expansion and highlighting.
Changed CMP_TREE_NODE_LIB_ID type from ALIAS to LIBID for more accurate
description.
Use LIB_ID in COMPONENT_SELECTION object instead of strings of the
library and symbol names.
Remove all symbol libraries from the project file after remapping to
prevent symbols that should be loaded from the cache being loaded from
a library further up the search order. Save the project file to clear
all of the libraries so they never get reloaded again.
Remove the symbol library management dialog and menu entries.
Rename the symbol library table dialog menu entry.
Remove all symbol libraries from default project file to prevent clashes
with the cache library.
Fix illegal symbol naming in Eagle plugin.
Refactor rescue objects so that they can support derivation.
Factor out legacy rescuer code to perform legacy project rescues.
Create new symbol library table rescuer for rescuing symbol library table
based projects.
Perform the correct rescue type on project load.
Add symbol library table remapping support to the tools menu for run on
demand as applicable.
Add flag to SCH_SCREENS::UpdateSymbolLinks() to allow forcing the symbol
link updates when the library modification hash has not changed.
Simplify some of the library editing code. There have been a few minor
changes in the behavior of the editor. If the current symbol is deleted
from the library, the next symbol in the library is not loaded. The
deleted symbol is cleared and the current symbol is empty.
Change component to symbol to align with the preferred terminology
discussed on the developer's mailing list.
Add separate update UI event for save library as to enable the menu entry
whenever a library is selected.
Change the select symbol list dialog to a single column using the LIB_ID
format LIB_NICKNAME:LIB_ITEM_NAME so that the selection can be parsed by
LIB_ID.
Add method to expand URI to LIB_TABLE_BASE.
Override wxApp::OnExceptionInMainLoop() in debug builds to make debugging
easier when an unhandled exception occurs in a wxUpdateUIEvent handler.
Change SCH_SCREENS::HasNoFullyDefinedLibIds() to return false when the
schematic has no symbols to prevent the remapping dialog from being run.
Use SCH_COMPONENT part reference when creating netlist rather than looking
up the library symbol.
Change all of the component tree helper objects to use LIB_IDs instead of
LIB_ALIAS pointers. LIB_ALIAS pointers are dangerous to use because they
can be deleted in the symbol library editor while the component chooser
dialog has copies of them. With LIB_IDs, the LIB_ALIAS pointer is found
on demand and can be guaranteed to be valid.
Update the chooser dialog to load the symbol library table instead of the
libraries defined in the project file and return a LIB_ID instead of a
LIB_ALIAS pointer.
Modify SCH_BASE_FRAME::SelectComponentFromLibrary() to handle the LIB_IDs
returned from the component chooser dialog.
Use GetPath() instead of GetFullPath() when initializing environment
variable table entries KICAD_SYMBOL_DIR and KICAD_PTEMPALTE due to
unexpected trailing path separator which was causing find libraries
by URI to fail.
Don't create a project symbol library table when there are no libraries
not found in the global symbol library table.
Don't add non-existent libraries to project symbol library table.
Clear symbol library table when loading a new schematic.
Minor remapping status message improvements.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.
Fix issues when resolving the library symbol links in the schematic
symbols.
Add cache library fallback when resolving symbols that cannot be
remapped.
Add remap complete message to remap dialog.
Add HasLibrary() helper to LIB_TABLE_BASE.
Fix issues when loading library symbols using symbol library table.
Add hashing function to symbol library table.
Improve the symbol panel message to warn user when cache library is
used to resolve symbol.
- set a proper title for the dialog
- changed the library parser delimiters to all whitespaces
- sorts the model list in the alphabetical order
- one tab to select subcircuit and semiconductor models
- model type is automatically selected
This instead of using the library alias property. But to not break any
library. When adding new components to the schematic, copy the value
from the library into the Field variable only if the field variable would
otherwise be empty.
This way, the context menu for showing the docs is more understandable
for users, and is also changeable from the schematic without having to
modify the actual libraries.
Fixed: lp:1723104
(On windows, xsltproc.exe does not accept '\' in output filename, only '/' like on Unix, so this separator is converted when possible)
Minor code cleanup
Don't prompt the user to save the project file after the schematic plot
settings change. It is not done this way anywhere else in KiCad.
Fixes lp:1478131
https://bugs.launchpad.net/kicad/+bug/1478131
- pad names are stored as wxString instead of a char[4] & integer union
- removed pad name to string conversion functions
- fixed pad & pin properties dialog restrictions regarding the name
length