Commit Graph

274 Commits

Author SHA1 Message Date
Jeff Young 133fb5cded Minor code cleanup. 2020-09-06 11:28:58 +01:00
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Wayne Stambaugh c17f832de1 Eeschema: move auto save check before clearing current screen.
GitLab issue #5068 only affected the 5.1 branch.  The same issue could
also affect master if for some reason a context switch occurs due to
changes.  Moving the auto save feature before setting the current screen
to null should mitigate any potential future issues.
2020-09-01 16:52:05 -04:00
Mark Roszko 9f128f942c Move shutdown blocker to kiplatform 2020-09-01 10:14:51 +00:00
Jon Evans 9f7bca38b3 A better way of handling standalone project files 2020-08-30 16:04:39 -04:00
Jon Evans 24435fcc62 Don't create new project files when opening boards/schematics
Display warning infobar in the board/schematic setup when no project
is loaded, since most of the settings in those dialogs are saved in
the project and not in the board/schematic file.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/4868
2020-08-24 22:17:21 -04:00
Mark Roszko 89e74140eb Save file / window states for kicad project locally 2020-08-24 02:01:14 +00:00
Thomas Pointhuber a03fb7a9a8 Altium: Refactor and add initial structure for schematic importer
altium: move pcbnew/altium2kicadpcb_plugin -> pcbnew/plugins/altium

See: https://gitlab.com/kicad/code/kicad/-/issues/4412
2020-08-23 19:01:08 +00:00
Jeff Young f4ab14f32d Performance improvements for SchematicCleanup().
Fixes https://gitlab.com/kicad/code/kicad/issues/4563
2020-08-10 12:41:52 +01:00
Jeff Young f3b92903e2 Evidently the sheet client list isn't kept up-to-date.
Fixes https://gitlab.com/kicad/code/kicad/issues/5021
2020-08-02 19:58:15 +01:00
Jeff Young 173493b1a8 Try to store the actual sheet #, but don't store 1 for non-root sheet.
Fixes https://gitlab.com/kicad/code/kicad/issues/5021
2020-07-31 22:29:05 +01:00
Marek Roszko 9278660b10 Add support for the windows application restart api 2020-07-28 14:32:39 -04:00
Jeff Young 7340c97ef9 Undo for schematic-wide operations.
Editing value/footprint fields of multi-unit components.
Find/Change.
Annotation.
Back annotation.

Fixes https://gitlab.com/kicad/code/kicad/issues/2122

Fixes https://gitlab.com/kicad/code/kicad/issues/4869

Fixes https://gitlab.com/kicad/code/kicad/issues/3933

Fixes https://gitlab.com/kicad/code/kicad/issues/4871

Fixes https://gitlab.com/kicad/code/kicad/issues/3899
2020-07-13 12:32:17 +01:00
Jon Evans a2041073ee Skip project backup in standalone mode
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4867
2020-07-12 11:42:05 -04:00
Jon Evans fc92fb076e Cache sheet path to string conversion in UpdateSymbolInstances
Profiling of large designs (with many hierarchical sheets)
showed that this can be a huge (4x) speed up to schematic
loading times.
2020-07-09 18:14:37 -04:00
Jon Evans b1b9cef5fb Full-project automatic backup system
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4763
2020-07-09 13:55:19 +00:00
Jon Evans 788f31d743 Fix import of Eagle schematics
Old project needs to be unloaded before schematic is reset,
then new project has to be loaded before doing the import

Fixes https://gitlab.com/kicad/code/kicad/-/issues/4836
2020-07-07 20:48:32 -04:00
Jeff Young 509cd8f495 Remove duplicate fix not found by merge. 2020-07-05 21:01:19 +01:00
Jeff Young ec6c1b80b7 Fix a couple of bugs in the CurrentSheet architecture. 2020-07-05 19:53:04 +01:00
Jon Evans 04a51a5ba4 Push current sheet handling to SCHEMATIC
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4803
2020-07-04 20:59:35 -04:00
Jon Evans 0201cb4e7e Fix schematic reload in standalone mode 2020-07-03 10:43:23 -04:00
Jon Evans 498fa8d8ba Fix some things about template fieldname synchronization 2020-07-02 23:42:36 -04:00
Jon Evans 4dbbe1cf68 Project settings fixes from review
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
2020-07-02 22:08:54 -04:00
Jon Evans fe5959b625 Remove the schematic and board backup file system
Per discussion on the developers list, this old system
no longer provides much value and is seen as annoying
by many users.  The new save logic should prevent any
cases of file corruption on save, which was a major
reason for the backup file system existing.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2012
2020-07-02 22:08:54 -04:00
Jon Evans 12b4a55ae8 Port Eeschema to new project settings
DRC/ERC error serialization changed to use explicit tokens
Old stored severities and ignored errors are discarded
2020-07-02 22:08:54 -04:00
Jon Evans c0aa6965de Migrate PcbNew project settings to new framework
Various architecture upgrades to support this.
Creating a BOARD now requires a valid PROJECT, which caused
some (mostly transparent) changes to the Python API internals.

ADDED: Project local settings file
CHANGED: Board design settings are no longer stored in PCB file
CHANGED: Net classes are no longer stored in PCB file
CHANGED: Importing board settings now reads boards, not just projects

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2578
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4070
2020-07-02 22:08:54 -04:00
Jon Evans 0e2f9cb1bd Migrate CvPcb project parameters 2020-07-02 22:08:54 -04:00
Jon Evans a4fadfcdf2 Begin moving project file load to new system 2020-07-02 22:08:54 -04:00
Jon Evans a7708fa6dc Add PROJECT_FILE and basic load/unload methods 2020-07-02 22:08:54 -04:00
Jon Evans 09cb75b8a1 Use a temporary file when saving boards/schematics to make the operation more atomic
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4517
2020-06-19 23:31:26 +00:00
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Wayne Stambaugh b624c7090a Deprecate saving legacy schematic and symbol library file formats.
REMOVED: The ability to save schematics in the legacy file format.
2020-05-29 12:43:00 +00:00
Jon Evans e934f8b459 Remove python netlist QA facilities 2020-05-23 22:48:09 -04:00
Jon Evans a63df2fbf0 Remove BuildNetListBase from netlisting paths 2020-05-23 13:14:05 -04:00
Jon Evans 2499a1d640 Remove KIWAY dependence from SCH_PLUGINs 2020-05-20 23:00:23 -04:00
Jon Evans b074cdf185 Ensure that eeschema loads project params in standalone mode 2020-05-19 23:57:53 -04:00
Ian McInerney 73a1ce3e84 Move eeschema find notification to the infobar and improve the infobar widget
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time

CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
2020-05-20 02:31:47 +01:00
Wayne Stambaugh 28b8e75211 Fix duplicate time stamp bug when loading legacy schematics. 2020-05-19 11:01:00 -04:00
Ian McInerney a2f027e063 Add an infobar widget to display information above the canvas
This widget allows for non-intrusive display of text
above the editing canvas. Currently, this is used
for displaying the read only status of the files.
2020-05-19 00:46:33 +01:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 84160c1da4 Fix typo.
Fixes https://gitlab.com/kicad/code/kicad/issues/4448
2020-05-15 00:27:19 +01:00
jean-pierre charras 2cf82d9129 fix a wxWidgets minor alert and compil warnings 2020-05-13 08:53:32 +02:00
Jeff Young 724c669434 Move a few more commands to tool framework. 2020-05-12 18:12:38 +01:00
jean-pierre charras bc24d8e957 Fix typo and I18N string 2020-05-10 16:55:15 +02:00
Wayne Stambaugh e253862f77 Eeschema: remove automatic conversion of time stamp UUIDs.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed.  If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.

The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost.  This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
2020-05-07 09:26:43 -04:00
Wayne Stambaugh 9c99286385 Fix a few Coverity warnings. 2020-05-05 16:42:59 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jon Evans 2eaefb4874 Improve performance of schematic load and connectivity
Store component paths and references efficiently
Remove redundant calls to RecalculateConnections
2020-04-30 19:53:25 +00:00
Jon Evans b802a3e776 Add command-line option to generate netlist and exit 2020-04-19 19:13:24 -04:00