Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)
Fixes https://gitlab.com/kicad/code/kicad/issues/5397
GitLab issue #5068 only affected the 5.1 branch. The same issue could
also affect master if for some reason a context switch occurs due to
changes. Moving the auto save feature before setting the current screen
to null should mitigate any potential future issues.
Display warning infobar in the board/schematic setup when no project
is loaded, since most of the settings in those dialogs are saved in
the project and not in the board/schematic file.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4868
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
Per discussion on the developers list, this old system
no longer provides much value and is seen as annoying
by many users. The new save logic should prevent any
cases of file corruption on save, which was a major
reason for the backup file system existing.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2012
Various architecture upgrades to support this.
Creating a BOARD now requires a valid PROJECT, which caused
some (mostly transparent) changes to the Python API internals.
ADDED: Project local settings file
CHANGED: Board design settings are no longer stored in PCB file
CHANGED: Net classes are no longer stored in PCB file
CHANGED: Importing board settings now reads boards, not just projects
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2578
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4070
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time
CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
This widget allows for non-intrusive display of text
above the editing canvas. Currently, this is used
for displaying the read only status of the files.
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed. If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.
The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost. This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects. It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic). This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet. This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references. It also allows the root schematic from one project
to be uses as a sub-sheet in another project.
When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs. This is done to ensure there
are no sheet path instance clashes between projects. That being said,
there are no checks for this. It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.