Commit Graph

83 Commits

Author SHA1 Message Date
Jon Evans 487aa37d2e Connectivity: don't rename things multiple times in subsheets
Depending on what order the subgraphs are processed in, it's
possible to hit a case where the parent sheet renames a bus
member before the bus neighbor renaming logic runs.  In this
case, we don't want to apply the bus neighbor logic as it will
break connectivity to the parent sheet if that bus was not
also renamed (for example, if the hier ports only make net
connections and not bus connections)

Fixes https://gitlab.com/kicad/code/kicad/-/issues/6887
2020-12-29 16:42:30 -05:00
Jeff Young 10e68daa37 Fix some bugs in Change Symbol and Update Symbols.
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).

Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.

Fixes https://gitlab.com/kicad/code/kicad/issues/6733

Fixes https://gitlab.com/kicad/code/kicad/issues/6749
2020-12-15 16:12:17 +00:00
Jeff Young 797a588015 Aliases should inherit their descs, keywords, and fp filters.
Assuming they're not set locally, of course.

Also updates to new class structure order.

Fixes https://gitlab.com/kicad/code/kicad/issues/6051
2020-12-14 13:48:26 +00:00
Jeff Young 9ece90a541 Fix off-by-one error in exporting netlist, and update testcases.
The golden file update entails the change to no-connects as well as
the introduction of natural number ordering.
2020-12-04 19:37:55 +00:00
Jeff Young c67c13bc1d Update netlist goldens (properties, natural order, no-connect nets). 2020-11-23 22:09:15 +00:00
Jeff Young b227d2b910 More component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young 6654c03041 Embarking on the next adventure: component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young 8a4992b528 Add missing file. 2020-11-14 22:09:43 +00:00
Jeff Young d094f86b1a Finish module cleanup (except for xpms). 2020-11-14 22:00:12 +00:00
Jeff Young 61bca4aaa4 A bit of "module" erradication, nameing conventions, and formatting. 2020-11-14 21:21:54 +00:00
Jeff Young f0d0e17aab Prepare for MODULE -> FOOTPRINT. 2020-11-13 15:16:24 +00:00
Jon Evans a900fb319d Add testcase for bus junctions problem 2020-10-27 23:02:49 -04:00
Ian McInerney 31e626f279 Cleanup creation of all our smart pointers 2020-10-26 23:52:44 +00:00
Jeff Young 909dca71cd Fix test_sch_sheet_list to run headless. 2020-10-21 13:45:02 +01:00
Wayne Stambaugh 8ff51d8899 Eeschema: add schematic sheet page number.
The groundwork has now been laid for per sheet instance data.  Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.

ADDED: Support for user defined schematic page numbers.
2020-10-19 14:05:45 -04:00
jean-pierre charras 539ac4c214 Remove a few include<wx/wx.h> in many files that do not actually use this include. 2020-10-19 09:00:50 +02:00
Jon Evans 61f731aa1d Fix disambiguation for vector buses with different ranges
Previously disambiguation was looking for exact matches,
but vector buses are permitted to have different ranges and
still participate in merging, so they need to be disambiguated.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/5925
2020-10-08 22:26:24 -04:00
Tomasz Wlostowski bd27d38d9a DRAW_PANEL_GAL: added DebugOverlay() method, creating a temporary overlay for drawing debug graphics 2020-10-07 16:36:37 +02:00
Wayne Stambaugh d45c11b4b5 Exclude from bill of materials and board netlist to library symbols.
ADDED: Support for exclude from bill of materials and board netlist to
library symbols.

Fixes https://gitlab.com/kicad/code/kicad/issues/4915
2020-09-09 09:03:37 -04:00
Seth Hillbrand 02a5d47de9 Avoid passing references in EESchema
This returns the connection list by value.  This allows easier Python
use

Also renames m_End() to GetEnd()
2020-09-08 06:29:27 -07:00
Jeff Young e6f4e156b6 Fix the SCH_PINs test to be more reflective of the codebase. 2020-09-01 15:25:49 +01:00
Wayne Stambaugh ede39780e2 Remove all debugging output that cannot be disabled.
The use of printf, wxLogDebug, and std::err/std::out causes excessive
debugging output which makes finding specific debugging messages more
difficult than it needs to be.

There is still some debugging output in test code that really needs to
be moved into a unit test.

Add debugging output section to the coding policy regarding debugging
output.
2020-08-18 10:17:36 -04:00
Ian McInerney 7b705af038 Refactor common QA components to create a single common library
This moves the program-specific code (e.g. BIU files) into
the program tests.

Also, create title_block.cpp to break a dependency that pulled
in eda_text.cpp when using the TITLE_BLOCK object.
2020-07-18 16:21:15 +01:00
Jeff Young 1872d05f72 Fix netlist test golden file to include proper escaping. 2020-07-07 11:18:52 +01:00
Jon Evans 4dbbe1cf68 Project settings fixes from review
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
2020-07-02 22:08:54 -04:00
Jon Evans 12b4a55ae8 Port Eeschema to new project settings
DRC/ERC error serialization changed to use explicit tokens
Old stored severities and ignored errors are discarded
2020-07-02 22:08:54 -04:00
Jon Evans a4fadfcdf2 Begin moving project file load to new system 2020-07-02 22:08:54 -04:00
Jon Evans a7708fa6dc Add PROJECT_FILE and basic load/unload methods 2020-07-02 22:08:54 -04:00
Jon Evans e91b9f6dfb Rip out the unused leftovers of the old color system 2020-06-18 22:32:14 -04:00
Wayne Stambaugh 52078a4b1b Allow setting mandatory derived symbol field properties.
CHANGED: All mandatory fields in derived symbols can be edited.  This
not only includes the field value but also all text properties.

Kill the dual datasheet variable storage which caused many datasheet
bugs over the years.  The datasheet is now always stored in the data
sheet field.
2020-06-02 14:21:11 +00:00
Jon Evans e934f8b459 Remove python netlist QA facilities 2020-05-23 22:48:09 -04:00
Jon Evans f730aa7834 Update netlist testcases 2020-05-23 22:48:03 -04:00
Jon Evans f7578eb038 Implement new native netlist QA test 2020-05-23 21:04:11 -04:00
Jon Evans de9520d65e Finish porting netlisters to use CONNECTION_GRAPH 2020-05-23 12:45:24 -04:00
Jon Evans 7c7b7f41da Move SCH_SCREEN project access to SCHEMATIC
SCH_SCREEN no longer needs to be a KIWAY_HOLDER
2020-05-20 22:27:48 -04:00
Jon Evans b36b7d5a5d Update video QA project with proper junctions 2020-05-20 18:51:32 -04:00
Jon Evans 52ae0df7a4 Convert video QA project to new format 2020-05-20 00:03:27 -04:00
Jon Evans 9e79dfdb25 Update netlist QA testcases to new file format 2020-05-18 22:40:28 -04:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jon Evans 920f5f4ada Update netlist qa files for new format 2020-05-05 21:58:08 -04:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jeff Young 1535c83b88 Lay some groundwork for adding distances to DRC errors.
modified:   eeschema/lib_rectangle.cpp
2020-04-24 14:46:22 +01:00
Jon Evans d7d1ea33ac Check for conflicts before promoting sheet pins to be strong drivers
Fixes https://gitlab.com/kicad/code/kicad/issues/4201
2020-04-19 19:13:24 -04:00
Jon Evans 7df3df3381 Add basic netlist QA test 2020-04-19 19:13:24 -04:00
Jon Evans b802a3e776 Add command-line option to generate netlist and exit 2020-04-19 19:13:24 -04:00
Ian McInerney d44a252182 Clean up spice tests in qa_eeschema
* Guard their inclusion with the KICAD_SPICE flag
* Code cleanup inside actual testing function

Fixes https://gitlab.com/kicad/code/kicad/issues/4220
2020-04-18 00:47:40 +01:00
Sylwester Kocjan fdccdd5cb9 Eeschema: adding .op SPICE simulation support
ADDED new tab on simulation settings dialog, which allows to run .op analysis.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2368
2020-04-15 01:51:58 +00:00
jean-pierre charras 4a2a5a9403 qa_eeschema: fix a crash due to LIB_PIN ctor that was using default config values,
but in QA tests, we do not have config values available.
2020-04-14 18:12:15 +02:00
Jeff Young 4990d1e7b2 Variable substitution framework.
This implements editing of variables and moving SCH_FIELDs,
TEXTE_MODULEs, TEXTE_PCB and worksheet items over to the new
framework.
2020-03-30 14:15:59 +01:00
Jeff Young 085d80e3f3 Remove duplicated settings from preferences.
These have now moved to project-specific settings.
2020-03-13 17:28:53 +00:00