- Fix parsing .model lines with model names containingnon-alphanumeric
characters like - and _,
- Fix parsing libraries in which EOF is not preceded by a newline.
Fixes https://gitlab.com/kicad/code/kicad/issues/12394
* fix broken float values in countries using a comma as separator (missing LOCALE_IO switch)
* fix regression that ignored the pseudo directive Kxx Lyy Lzz nn (coupling factor)
* fix regression that created empty blocks for .subckt and .control
Only pins from the current symbol part were used: the rest was
incorrectly set to Not Connected.
Also slightly change generation of names for Not Connected nets.
This change removes the incorrect assumption that symbol pin numbers are
integers and are the same as indexes in the vector storing the symbol
pins.
"~" is now used to denote a floating sim model pin.
ba7a06f5 tried to fix a (minor) issue in net names when the name was coming
from a input power pin having a '/' in name. But ba7a06f5 blindly escaped any '/'
in net name, and the hierarchy info was lost.
Now only the pin name is escaped (like any other pin name used in net names)
1) Move a bunch of std::map's to std::unordered_map to get constant-time
look-ups
2) Lengthen progress-reporting intervals to spend more time doing work
and less time talking about it
3) Reverse order of SHAPE_LINE_CHAINs in thermal intersection checks to
make (much) better use of bbox caches
4) Don't re-generate bboxes we already have
5) Fix some autos that weren't by reference (and were therefore copying
large datasets)
6) Rename delta progressDelta so it's easier to search for in future
7) Get rid of a few more autos (because I don't like them)
8) Pass large items to lambdas by reference
Fixes https://gitlab.com/kicad/code/kicad/issues/12130
Unfortunately, Windows headers define a lot of macros for common words,
so we had to rename some enums to not collide.
We also fix some of the many bugs related to the new simulation
architecture and the Spice Model Editor dialog.
- Tab-switching,
- Automatic expansion of categories on tab-switch,
- Various minor simulation improvements,
- Various new simulation-related bugfixes.
Don't serialize parameters in certain models for default values. Infer
models from Value field for some kinds of models. Resolve synonyms when
loading models from Spice libraries.
Rewrite the spice exporter to work with the new simulation model
architecture and data model, with many bugfixes related to the latter
two along the way.
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017
Exporting the Bill of Materials uses the netlist exporter. Both of
these routines were stripping the extension, leading to projects like
"test.project.kicad_pro" having the project name stripped. We separate
the BOM netlist export from generic plugin netlist export to allow the
correct behavior when exporting netlists and generating BOMs
Fixes https://gitlab.com/kicad/code/kicad/issues/10270
(cherry picked from commit bef762e652)
Unused variables in function calls can be commented out. Unused
return variables get a new routine `ignore_unused()` that silences the
warnings with zero overhead.
This function attempted a poor-man's natural compare but it assumed
specific structure of the string. This broke for strings with
numberings that looked like decimals.
Instead, we use our natural string comparison function and remove the
references to this older function and its similar elements.
Fixes https://gitlab.com/kicad/code/kicad/issues/9067
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
SCH_PIN wasn't handling the legacy empty string token (~), but
more importantly this will allow text variable resolution specific
to the schematic.
Fixes https://gitlab.com/kicad/code/kicad/issues/8625
Each symbol unit in eeschema has a unique identifier. But we don't have
a unique identifier for the entire symbol. So changing which symbol
instance was unit A (our default base for matching), changed the UUID
that we were using to match the footprints.
This commit adds all UUIDs to the netlist, allowing us to match symbol
to footprint without worrying about which unit is referenced.
This still does not handle changing different units on different sheets.
Fixes https://gitlab.com/kicad/code/kicad/issues/7604
ADDED a new pin electrical type "free" for internally unconnected pins.
CHANGED the "unconnected" pin electrical type is now represented by
"no_connect" in files and netlists. (The legacy syntax is also accepted
in files.)
This way the net names can be inspected in eeschema and cross-probing works.
Testcases updated for the name changes
CHANGED: all unconnected pins are now included in the netlist with no_connect_ prefixes
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).
Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.
Fixes https://gitlab.com/kicad/code/kicad/issues/6733
Fixes https://gitlab.com/kicad/code/kicad/issues/6749
1) use SCH_COMPONENT::GetRef(), GetValue() and GetFootprint() when
instance-specific info is needed
2) update UpdateAllScreenReferences() to handle value and footprint.
3) BACKANNO is CvPcb's handler, not back annotation's handler. Which
means it needs GUI behaviour, not back annotation behaviour.
Fixes https://gitlab.com/kicad/code/kicad/issues/5520
This provides a method to add symbols that represent footprints on the
board that do not have an associate component such as mounting holes,
fiducials, logos, etc that should be excluded from the bill of materials.
It also prevents those footprints from being removed from the board
accidentally when updating the board from the schematic.
ADDED: Support to exclude schematic symbols from bill of materials
export.
CHANGED: All mandatory fields in derived symbols can be edited. This
not only includes the field value but also all text properties.
Kill the dual datasheet variable storage which caused many datasheet
bugs over the years. The datasheet is now always stored in the data
sheet field.
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects. It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic). This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet. This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references. It also allows the root schematic from one project
to be uses as a sub-sheet in another project.
When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs. This is done to ensure there
are no sheet path instance clashes between projects. That being said,
there are no checks for this. It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
The RTree does not have a deterministic iterator, so extracting items
may be in arbitrary order, causing issues as the schematic appears to
change when comparing to previous revisions.
This uses the SCH_ITEM comparison operator to for ordering by type, then
by custom sorting within type.
For the netlist, we choose the first available unit in the sheet for
each component.
Fixes#3811 | https://gitlab.com/kicad/code/kicad/issues/3811
Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
Spice lines defining circuit elements are contained in a .subckt ..
.ends block. The intervening lines should be exported to the netlist as
well as the control lines.
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
This change completely removes the LIB_ALIAS design pattern an replaces
it by allowing LIB_PART objects to inherit from other LIB_PART objects.
The initial implementation only allows for single inheritance and only
supports the mandatory fields in the derived part because that is all
that the current symbol library file format will support. Once the new
file format is implemented and saving to the old file format is deprecated,
more complex inheritance will be added. The LIB_ALIAS information saved
in the document files was move into the LIB_PART object. This change
impacts virtually every part of the schematic and symbol library editor
code so this commit message is woefully incomplete.
REMOVE: Removed the symbol aliases concept from the schematic and symbol
editors and the symbol viewer.
NEW: Replace the symbol alias concept with simple inheritance that allows
a library symbol to be derived from another library symbol.
The pin name defined in Eeschema is now available as pad info.
Useful for the board designer (the pin function is displayed in the message panel).
Needed for the Gerber P&P files.