The drivers need to get passed up and down the hierarchical sheets. In
order to do this, both the sheet pin and the hierarchical pin need to
be in the changed items. However, we only get sheets in the screen
items list while the pins are the elements that get set dirty
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17797
Netclass assignments are stored in the project level but
CONNECTION_GRAPH updates would clear the assignments. This keeps
existing netname->netclass assignments but updates any netnames that
were changed by the incremental updates. Absolute updates are not
affected and fully recreate the net name to netclass map
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17720
The connectivity routine would consider symbols, overwriting unused
subgraphs for pins that were not in the change list. This is resolved
by updating the full connectivity to only use pins in the graph since
symbols are not connected independently.
In the process of adding QA tests for this change, additional issues
with the schematic QA were discovered. Specifically, we were not
properly setting the root sheet UUID. This was partially masked by a
const_cast setting of the RefDes in sch_symbol when called the RefDes
getter. This exposed the fact that our QA ERC numbers did not match the
schematic editor stand alone ERC numbers. So the test value for one
check needed to be updated
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17528
Per the if statement and logic, we want to walk into looking up connections if we are a pin on a chip.
IsGlobalPower is a test for it's in a power symbol, so we want it false not true.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16699
Also fixes a bug where ERC testing for text variables in sheet pins
would start with the wrong sheet.
Also fixes a bug where ERC testing of similar labels would use the
wrong sheet.
Also fixes a bug where ERC testing of bus-to-net conflicts would use
the wrong sheet.
Also fixes a bug where ERC didn't process variable references when
checking hierarchical labels against sheet pins.
Also fixes a bug where ERC multiple-drivers and netclass-conflicts
tests didn't set a sheetpath.
We used to store the symbol units of the current sheet and then
restore them, but we didn't handle the dangling states.
The new code uses a different strategy and just makes sure that if
any of the sheets are going to modify the current screen, the current
sheet gets to go last so that its modifications will "stick".
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15392
When generating virtual connections to represent bus aliases, we need to
store the pointers for future deletion otherwise we will leak the memory
(cherry picked from commit 9260f58803)
When running ERC, we want to check if bus members exist in the bus and
this should be done using m_local_name (i.e. the name it take from the
parent bus) not the resolved name as this will change depending on
connections
(cherry picked from commit 1380feef72)
We store our connectivity dirty flag with the SCH_ITEM but we generate
SCH_CONNECTION based on the SCH_ITEM and the SCH_SHEET_PATH. For this
reason, we need to avoid clearing the connectivity dirty flag until
we've finished processing all instances of the SCH_ITEM in the graph
This also means that we need to allow getting the SCH_CONNECTION pointer
even when the connectivity is still dirty (getting SCH_CONNECTION
happens based on SCH_ITEM and SCH_SHEET_PATH, not just SCH_ITEM)
- Incremental extraction needs the newly created items. The modified
items are already set in the connection graph but the newly created
items don't exist yet, so we need to add those explicitly
- Bus parents need to ensure that the bus children exist because we
iterate on the updates from the top of the graph down
We have a break somewhere in the connectivity that doesn't fully process
connections but the current code seems to catch these by forcing a
top-down & bottom-up calculation
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14818
While it's a bit of an encapsulation leak (see comment in
CONNECTION_SUBGRAPH::driverName()), it more than doubles undo/redo
performance in documents with *lots* of nets.
Aliases in bus resolution were being resolved without a path, making
them effectively global nets. This applies the corrected path to the
bus members and adds a QA to catch this error
[ADDED]: A panel to the schematic editor that allows quick access to all
of the items connected to the currently highlighted net.
This is an initial swag at implementing a full net navigator feature. For
now it only shows the currently highlighted net nodes. The incremental
net list advanced setting must be enabled in order to use this feature due
to performance reasons. There are still some issues with saving the panel
position which will be addressed in the future.
Initial code for serializing wxAuiPaneInfo settings to and from JSON have
be implemented.
The propagation is currently (maybe not needed) limited to the global
name that is the source of the change. We also need to propagate the
global name that is changed in case the global is set in a tree leaf and
not the root
Fixes https://gitlab.com/kicad/code/kicad/issues/14657