Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
It turns out the fastest way to update wxDataViewCtrl is to nuke the
model and rebuild it from scratch rather than via
ItemAdded()/ItemDeleted() update notifications.
Fixes: lp:1734773
* https://bugs.launchpad.net/kicad/+bug/1734773
CHANGE: In Eeschema, when placing a component directly over an existing
wire, the wire is automatically removed where it shorted pins.
This helps workflow in Eeschema, allowing one to quickly add components
to existing lines.
Fixes: lp:1678449
* https://bugs.launchpad.net/kicad/+bug/1678449
This target seems to only create empty makefiles, tested on linux. And I
can not find any references to it in any of the current CMakeLists. Lets
remove it.
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
- Reverts behaviour of 3e71ed2421
- 3D model offset now explicitly written in mm, using "offset" tag
- Any read "at" tag is converted from inches to mm
- This will not break any 3D model offset when reading files
- It will however render files incompatible with old versions
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic
Remove developer email addresses as requested on the developers mailing
list.
Update source contributor list.
Add place holders for symbol and footprint library contributors.
Remove unnecessary wxT() macros.
SCH_LINE can represent a bus, wire or graphic line. Checking
for the corner needs to distinguish between these types.
Fixes: lp:1635984
* https://bugs.launchpad.net/kicad/+bug/1635984
LAYER_NON_PLATED to LAYER_NON_PLATEDHOLES
LAYER_PADS_HOLES to LAYER_PADS_PLATEDHOLES
LAYER_PADS to LAYER_PADS_TH
and add comments and fix a render issue in gal mode for non plated holes.
Change action message color from "darkgreen" to "dark green" as the
former does not exist on windows and results in debug log warnings.
Change the information color from "grey" to "dark grey" for improved
contrast with the white backgrounds. This may need to configurable
on systems where the HTML window has a dark background color.
Don't translate HTML formatting strings.
Opening Properties dialog normally does not ask the user to confirm the
action, even for locked items. The exception was a case when there was
nothing selected and Properties dialog was invoked via its hot key -
then SELECTION_TOOL::RequestSelection() tried to get the item under the
cursor, verifying the lock flag.
Fixes: lp:1734537
* https://bugs.launchpad.net/kicad/+bug/1734537