(It is a container to build bridges on solder mask layers by DRC, not real zone)
Disable also this special zone selection by adding it in
PCB_SELECTION_TOOL::itemPassesFilter
Do not display the outlines of this very special zone used by DRC
to show layer mask bridges created by DRC to show these bridges.
From Master branch
Fixes#15847https://gitlab.com/kicad/code/kicad/-/issues/15847
Don't open-code knockout text shape generation in several different
places.
Make sure triangulated knockout text gets clearance added when
specified.
Collapse duplicated footprint text item plot routine (they're no
longer any different from plotting pcb text items).
(cherry picked from commit c71cf21e2f)
Version 7 text alignment changed subtly for stroke fonts from version 6.
Additionally, the output has been different between screen and plotting,
leading to offset text in plotted output relative to the text shown on
screen.
This introduces a fudge factor in FONT::getLinePositions to correct the
offset in the plotting output relative to v6.
This also changes the SCH_PAINTER and PCB_PAINTER to correct the
relative offsets between GAL and PLOTTER classes. The source of these
offsets is atm unclear.
Fixes https://gitlab.com/kicad/code/kicad/issues/14755
(cherry picked from commit 0de24bfd59)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
Includes changing the class hierarchy so that dimension objects inherit
from PCB_TEXT rather than containing a PCB_TEXT member variable.
(cherry picked from commit 23accffc6d)
If the pad hasn't already been owned by another zone, and the zone we're
currently filling can connect to it, then we want to try to flash it even
if it's not connected to anything else.
Fixes https://gitlab.com/kicad/code/kicad/issues/13415
Rather than moving the netname around, we want to keep the correct
number of netnames on a track such that there is always at least one
displayed on long tracks even when panning.
This reduces calculation time while keeping the netnames visible
Fixes https://gitlab.com/kicad/code/kicad/issues/12436
1) The highest priority zone that a via/pad collides with "owns" its
connectivity state. Once set, lower priority zones cannot change it --
and in fact, if they would have connected to it are forced not to.
2) The connectivity state goes with the zone fill state, and therefore
must be saved in the file.
3) Display of remove-unconnected's pads is no longer done in GetViewLOD()
(which isn't called for selected items), and is instead done in PCB_PAINTER.
This allows us to draw the full pad in outline mode when a via/pad is
selected which would otherwise only show the hole.
4) Note that in some cases this will still generate DRC errors -- in
particular when a via nearly collides with a higher priority zone it
won't get "owned" by that zone and may therefore have insufficient
clearance if said zone concludes it's unconnected and a subsequent
(lower priority) zone connects to it (causing it to now become flashed).
Fixes https://gitlab.com/kicad/code/kicad/issues/11299
(This is for the move tool, not DRC. DRC uses more sophisticated keepout
processing which is too slow for the move tool, and doesn't let us know which
keepout area collided for collision highlighting.)
Fixes https://gitlab.com/kicad/code/kicad/issues/12594