EEschema optimizes wires by merging colinear segments. If a schematic opened without a valid
cache library or missing installed libraries and later saved, this optimization can cause connectivity
errors. In order to fix that we check each pin-wire connection and junctions if necessary.
Also changes the presentation of the string when the checkbox appears
so that the "Changes will be lost" warning isn't hidden by the turndown.
This last part may require conditional compilation as it's undocumented.
Lastly, regularizes the Unsaved Changes strings between the apps.
After importing Eagle files, we need to make sure that the connectivity
network is updated before the system requests a new netlist. Otherwise,
we end up with different results from the first to second updates.
Don't prepend "/" for nets at the top level
Revert "Don't prepend "/" for nets at the top level"
This reverts commit fa9533222f7d33eee5f3fa2320bd9f3167e28076.
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Autosave was not working correctly, partly due to different
implementations in eeschema and pcbnew and partly due to a mistaken
refactor at some point during v5 development. This unifies the expected
autosave prefix to _autosave- for both pcbnew and eeschema. It also
unifies the expected suffix for the backup files to -bak.
Fixes: lp:1820433
* https://bugs.launchpad.net/kicad/+bug/1820433
Do not keep pointer to SCH_EDIT_FRAME in the rescuer object to prevent
it from creating dialogs with itself as the parent when call from the
rescue dialog which is itself a grandchild of the frame window.
Eagle can label nets independently of the connection point position. In
an "interestingly" designed circuit, this can lead to a junction of a
pin, wire endpoint and unrelated wire. While this is bad practice,
KiCad shouldn't force an incorrect net connection during the import. In
this case, we skip the addition of junctions to ensure that we don't
create a schematic error.
Fixes: lp:1788019
* https://bugs.launchpad.net/kicad/+bug/1788019
Clear the annotation of only the appended schematic and any sheets in it's
hierarchy. Do not clear the annotation of the symbols in the target sheet.
Fixes lp:1805695
https://bugs.launchpad.net/kicad/+bug/1805695
SCH_COMPONENTs should be added to VIEW only when symbol links are
resolved. Otherwise a dummy component bounding box will be used when
inserting a component to VIEW R-tree.
Fixes: lp:1801800
* https://bugs.launchpad.net/kicad/+bug/1801800
When importing an existing schematic into a sheet that was no remapped
to use the symbol library table, the user was given the option to ignore
the warning and proceed with the import. This would end up with all of
the imported symbol links being broke. In hindsight, this was a bad
idea so now the user cannot import schematics that have been remapped.
Fixes lp:1791280
https://bugs.launchpad.net/kicad/+bug/1791280
Reset lock file when saving a schematic sheet to a different file name.
This prevents a file is already open error from being displayed when
opening the original file.
Fixes lp:1788507
https://bugs.launchpad.net/kicad/+bug/1788507
This also fixes a bunch of bugs where an error during save would
still close the window (rather than cancelling the close action).
Fixes: lp:1785034
* https://bugs.launchpad.net/kicad/+bug/1785034
This removes the existing constructors so that all parsing must
be explicit and callers are made aware that they need to think
about illegal characters, malformed ids, etc.
Fixes: lp:1783474
* https://bugs.launchpad.net/kicad/+bug/1783474
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.
Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
Also adds indicators in layers palette for feedback.
Also generates sized images for all indicators instead of using
scaled bitmaps (which didn't look great).
Also fixes a completely unrelated typo in a UI string.
The Windows drive specifier C: was being interpreted as a valid URL by
wxURI which was performing a URL comparison instead of a file comparison
which always failed in LIB_TABLE_BASE::FindRowByURI(). Change test for
URI to search string for "://" to determine if the comparison should be
a URI (string) comparison or a file (wxFileName) comparison.
Don't run final rescue unless the user performs the remapping.