Commit Graph

169 Commits

Author SHA1 Message Date
Maciej Suminski 554cb54a4f Eagle SCH import: save project file after the full path is set
Fixes: lp:1765297
* https://bugs.launchpad.net/kicad/+bug/1765297
2018-04-20 10:04:41 +02:00
Wayne Stambaugh 81843c37a4 Organize trace debugging code for ease of maintenance. 2018-04-13 09:59:01 -04:00
Maciej Suminski 58c27398cb Eagle SCH import: improved implicit connections resolution
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.

Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
2018-04-12 18:12:22 +02:00
Wayne Stambaugh 696ff81dc7 Load correct schematic page layout description file in stand alone mode.
Fixes lp:1678849

https://bugs.launchpad.net/kicad/+bug/1678849
2018-04-04 10:18:12 -04:00
Maciej Suminski 2af51ef20f Eagle import: do not call TrimWire() on imported schematics
It turns out that TrimWire() may remove legit Eagle wires and effectively
change the netlist.
2018-03-04 18:04:19 +01:00
Maciej Suminski 260f680c6c Eagle import: fix memory leak on schematic sheets import 2018-03-04 16:47:26 +01:00
Maciej Suminski 8e8d95dd7f Eagle import: process all sheets when adding junctions; fix footprint LIB_IDs 2018-03-04 16:45:42 +01:00
Maciej Suminski 77346d81ce Eagle import plugin: add junction dots to fix connectivity 2018-03-04 16:45:42 +01:00
Maciej Suminski 1f078f533b Refactor Eagle project import to use Kiway::ExpressMail() 2018-03-04 16:45:42 +01:00
Wayne Stambaugh aeae32b1a2 Fix file naming bug when importing Eagle projects with . in file name.
Fixes lp:1747470

https://bugs.launchpad.net/kicad/+bug/1747470
2018-03-03 08:35:53 -05:00
Jeff Young 4dda8a39fe Add inc/dec current layer alpha to menus.
Also adds indicators in layers palette for feedback.
Also generates sized images for all indicators instead of using
scaled bitmaps (which didn't look great).
Also fixes a completely unrelated typo in a UI string.
2018-02-22 17:48:14 +01:00
jean-pierre charras 8022f1cc01 fix code after renamin files 2018-01-30 11:49:51 +01:00
Camille f5f7ba4746 Fix loop variable copy in for-range loop, use const reference instead 2018-01-09 19:18:44 -05:00
Wayne Stambaugh bf44d394c3 Eeschema: fix remapping bug on windows builds.
The Windows drive specifier C: was being interpreted as a valid URL by
wxURI which was performing a URL comparison instead of a file comparison
which always failed in LIB_TABLE_BASE::FindRowByURI().  Change test for
URI to search string for "://" to determine if the comparison should be
a URI (string) comparison or a file (wxFileName) comparison.

Don't run final rescue unless the user performs the remapping.
2018-01-03 08:37:54 -05:00
Seth Hillbrand f4f0c09fe4 Eeschema: Clear drawing state when loading project
Prevents stray flags from entering schematic editing process

Fixes: lp:1738894
* https://bugs.launchpad.net/kicad/+bug/1738894
2017-12-19 11:49:25 -05:00
Maciej Suminski 124c82f1cf Eagle Schematic Import: fixed imported libraries location
Standalone eeschema did not have the project path set when importing
a non-KiCad sheet. Due to this any libraries created during the import
were saved to the directory of eeschema executable instead of the actual
schematic directory.
2017-12-17 18:45:40 +01:00
Simon Richter a9ccf1161b Fix quotes in UI messages
This replaces all single and angle bracket quotes in UI messages with
double quotes, for consistency.

Sorry to all translators.
2017-12-15 07:33:07 -05:00
jean-pierre charras bfc3804115 Minor fixes related to timestamp_t. Move timestamp_t definition to base_struct.h 2017-12-07 13:33:59 +01:00
Henner Zeller 3f57fa5d24 Change time_t in the functions that deal with timestamps to a new typedef timestamp_t (defined as a long).
that makes sure the c++ side and swigged Python side agree on the type, because time_t create problems in Python scripts.
2017-12-07 13:16:33 +01:00
Wayne Stambaugh 8af9aa7574 Eeschema: allow for partial schematic loading.
With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded.  This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.

Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.

Check the error message contents when no exception was caught to warn
the user of any accumulated errors.

Fixes lp:1690644

https://bugs.launchpad.net/kicad/+bug/1690644
2017-12-06 19:11:09 -05:00
Seth Hillbrand 069448f20e Eeschema: Automatically manage junctions
CHANGE: eeschema automatically adds and removes junctions
when required by the schematic

Fixes: lp:593888
* https://bugs.launchpad.net/kicad/+bug/593888

Fixes: lp:1482111
* https://bugs.launchpad.net/kicad/+bug/1482111

Fixes: lp:1563153
* https://bugs.launchpad.net/kicad/+bug/1563153

Fixes: lp:1730219
* https://bugs.launchpad.net/kicad/+bug/1730219

Fixes: lp:1491052
* https://bugs.launchpad.net/kicad/+bug/1491052
2017-11-30 10:02:24 -05:00
Wayne Stambaugh 84e360dd0d Symbol library table remapping improvements.
Don't back up schematic files unless the user requests a remap.

Back up all files that could be changed by a remap including the
schematic file(s), cache library, project file, and rescue library
files.

Use an HTML control instead of a static text control for improved layout
of the user remap prompt.

Improve the user prompt in the remap dialog to make it clear that changes
will be made to project files.
2017-11-24 11:43:42 -05:00
Wayne Stambaugh e97ce6ee4f Use legacy schematic plugin for loading schematics in all code paths.
Use the legacy plugin schematic loader in the sheet edit and append
schematic code paths.

Check for fully qualified LIB_ID objects (must have library nickname)
when loading existing schematics when edit sheets.

Rewrite append schematic feature to handle import issues rather than
change the name and file name of all of the sheets in the imported
schematic.  This includes the following:
- Load the schematic into a temporary SCH_SHEET object.
- Make sure the imported schematic does not cause any hierarchy
  recursion issues.
- Verify the imported schematic uses fully qualified #LIB_ID objects
  (symbol library table).
- Check to see if any symbol libraries need to be added to the current
  project's symbol library table.  This includes:
- Check if the symbol library already exists in the project or global
  symbol library table.
- Convert symbol library URLS that use the ${KIPRJMOD} environment
  variable to absolute paths.  ${KIPRJMOD} will not be the same for
  this project.
- Check for duplicate symbol library nicknames and change the new symbol
  library nickname to prevent library name clashes.
- Update all schematic symbol LIB_ID object library nicknames when the
  library nickname was changed to prevent clashes.
- Check for duplicate sheet names which is illegal and automatically
  rename any duplicate sheets in the imported schematic.
- Clear all of the annotation in the imported schematic to prevent
  clashes.
- Append the objects from the temporary sheet to the current page.
- Replace any duplicate time stamps.
- Refresh the symbol library links.

Add support code to SCH_SCREEN object to assist with schematic import.

Doxygen comment cleaning.

Fixes lp:1731760

https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-18 08:10:58 -05:00
Wayne Stambaugh 652b969193 GTK+ file dialog wildcard improvements.
The GTK+ file dialog is case sensitive however it does support regular
expressions.  Most of the file dialog wildcards are lower case so only
files with the lower case extensions will show up in the file dialog.
This code adds a method to convert file extensions of any case to the
appropriate (sch -> [sS][cC][hH]) regular expression on GTK+ builds so
all file extension case combinations will show up in the file dialog.

A note to developers: make sure to add a file extension when setting
when setting the default file argument.  If you do don't set an
extension, the GTK+ file dialog will happily append the regular
expression as the file extension which is surely not what you want.

There are still a few known places (mostly gerbview) where there are
some complex wildcard code that has not been converted.

Fixes lp:1720542

https://bugs.launchpad.net/kicad/+bug/1720542
2017-11-11 19:32:26 -05:00
Wayne Stambaugh c1f7c1778a Revise symbol rescuer to support symbol library table.
Refactor rescue objects so that they can support derivation.

Factor out legacy rescuer code to perform legacy project rescues.

Create new symbol library table rescuer for rescuing symbol library table
based projects.

Perform the correct rescue type on project load.

Add symbol library table remapping support to the tools menu for run on
demand as applicable.

Add flag to SCH_SCREENS::UpdateSymbolLinks() to allow forcing the symbol
link updates when the library modification hash has not changed.
2017-11-09 18:50:20 -05:00
Wayne Stambaugh 96c3d5ff21 Enable symbol library table remapping.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.

Fix issues when resolving the library symbol links in the schematic
symbols.

Add cache library fallback when resolving symbols that cannot be
remapped.

Add remap complete message to remap dialog.

Add HasLibrary() helper to LIB_TABLE_BASE.

Fix issues when loading library symbols using symbol library table.

Add hashing function to symbol library table.

Improve the symbol panel message to warn user when cache library is
used to resolve symbol.
2017-11-09 18:50:17 -05:00
Maciej Suminski 444811ccfe Added exception handler for SCH_EDIT_FRAME::ImportFile 2017-10-20 09:34:32 +02:00
Maciej Suminski d617021d98 Added 'Import Non-KiCad Schematic' 2017-10-20 09:34:32 +02:00
Maciej Suminski 6b44d12bd8 Revert modifications to SCH_EDIT_FRAME::OpenProjectFiles() 2017-10-20 09:34:32 +02:00
Russell Oliver 2a0a999350 Eeschema Eagle Import: Code clean-up and formatting 2017-10-20 09:34:32 +02:00
Russell Oliver 3b0855d204 Eagle Project Import: Code cleanup and documentation.
- Also makes the project and file import functions filetype dependent.
- The change from IO_MGR::KICAD to IO_MGR::KICAD_SEXP removes a conflict from a compile definition for KICAD when compiling kicad/import_project.cpp
2017-10-20 08:58:40 +02:00
Russell Oliver 869743d573 Kicad Eagle Project Import Improvements. -- schematic and board files are both visible in file selection dialog. -- Allows for the selection of either the board or schematic file. -- silently fails on not detecting the corrosponding board or schematic file. -- all new kicad files are generated in new project directory -- Silently read netlist without generating annotation warnings which synchronises timestamps and paths based on given eagle references, otherwise renumbering schematic references will break links accross schematic and pcbnew. 2017-10-20 08:58:40 +02:00
Russell Oliver 433aa653fe Kicad: Add Project import function. -- add menu entry -- add ImportFile kiway function -- expose functions for creating/reading netlist -- add example eagle boad file as well 2017-10-20 08:38:42 +02:00
Maciej Suminski d6383893a2 eeschema: Iterate through plugins when determining file format. 2017-10-20 08:38:38 +02:00
Russell Oliver 4e69acbb49 Eeschema: Add CheckHeader function to SCH_PLUGIN and cycle through plugins when loading files. 2017-10-20 08:38:38 +02:00
Russell Oliver 7ea33f76b4 Eeschema: Determine file plugin to use from first line of file. 2017-10-20 08:38:38 +02:00
Maciej Suminski c727423979 Work in progress
- !! Eeschema uses Eagle plugin for loading schematics (i.e. it does not
use KiCad format anymore)
- Fixed build errors
- Fixed a few crashes
- Code formatting
2017-10-20 08:38:37 +02:00
Wayne Stambaugh 9c2ebf32f1 Initial symbol library table implementation prep work.
Add loading symbol library table code to schematic PROJECT object.

Fix minor issues with loading global symbol library table.

Add default symbol library path environment variable to the environment
variable list and change the variable name to KICAD_SYMBOL_DIR.

Add code to SCH_SCREENS to test if all library nicknames of the symbol
library IDs are empty.

Remove unnecessary KICAD_USE_SCH_IO_MANAGER build option.
2017-03-31 16:29:34 -04:00
Wayne Stambaugh 40f60c9871 Fix netlist generation bug cause when component unit is set to zero.
Fix if statement logic to ensure the unit number is never set to zero.

Add logic to the legacy schematic plugin to automatically convert any
schematic files that have components with a unit setting of zero.  Set
the schematic modified flag so that the user will be notified of a
changed schematic.

Add a user warning when the schematic parser fixes the bug and sets
the file modified flag.

Fixes lp:1677282

https://bugs.launchpad.net/kicad/+bug/1677282
2017-03-30 15:44:47 -04:00
jean-pierre charras 0b3e5952b7 Eeschema: fix a crash if a schematic project was not loaded due to a incorrect file format error (Linux only)
Fixes: lp:1670322
https://bugs.launchpad.net/kicad/+bug/1670322
2017-03-06 21:41:43 +01:00
Wayne Stambaugh d9260d42c8 Fix broken schematic symbol library links in sub-sheets.
Only the root sheet symbol library links were being updated when the
schematic was loaded so changed call to update all sheets.

Fixes lp:1670079

https://bugs.launchpad.net/kicad/+bug/1670079
2017-03-05 13:18:26 -05:00
Wayne Stambaugh 0898b6c94d Prevent symbol libraries from being unnecessarily reloaded.
When Eeschema is relaunched from KiCad, the symbol libraries were always
reloaded which isn't necessary as they are maintained by the kiface project
object until the project is changed.

Fix minor title capitalization in symbol library progress dialog.
2017-02-17 19:31:47 -05:00
Wayne Stambaugh e8cf4f0724 Fix bug in legacy schematic I/O plugin.
Move adding LIB_PART to library until the part is fully parse.  The problem
was unique_ptr was cleaning up the part when an exception was thrown during
parsing causing a double free when the cache was deleted.

Add missing try/catch block when loading the cache library during an append
schematic operation.

Fixes lp:1663869

https://bugs.launchpad.net/kicad/+bug/1663869
2017-02-11 20:19:52 -05:00
Wayne Stambaugh 73bbc35c3e Make the schematic I/O plugin the only option.
Add SCH_PLUGIN object to PART_LIB object.

Convert all PART_LIB I/O to use SCH_PLUGIN.

Remove library caching from PART_LIB and use caching provided by SCH_PLUGIN.

Add support to use PROPERTIES for buffering and document file write control
instead of adding code the SCH_PLUGIN object in the SCH_LEGACY_PLUGIN that
will not be required when the new file formats are implemented.

Add buffering to SCH_LEGACY_PLUGIN to prevent cache from writing file on
every change to library.  This is to prevent the cache library from being
written every time a new symbol is added.

Add option to not save library document file when saving library.  This is
primarily used by the cache library write code.

Move symbol library write code out of LIB_PART and into SCH_LEGACY_PLUGIN.

Add exception handling where LIB_PART caught the exception and returned
an error status.

Remove KICAD_SCH_IO_MANAGER build option as it is no longer optional.
2017-02-10 08:36:57 -05:00
Dick Hollenbeck 9ad49dc2d1 Split IO_ERROR out of richio.* and store Problem() and Where() separately 2016-09-20 11:56:18 -04:00
Nick Østergaard caafcde585 Add KICAD_ prefix to build switches
KICAD_ prefix was added to the USE_OCE and USE_SCH_IO_MANAGER build
switches together with a small description to the devdocs from
compiling.md.
2016-09-05 08:46:01 -04:00
jean-pierre charras 13cfe74956 Simulator dialogs: fix minimal sizes and best sizes. 2016-08-20 17:25:51 +02:00
Wayne Stambaugh 98ad5096b0 Eeschema: add saving schematic files to schematic plugin.
* Add SCH_PLUGIN::Save() for current file format and code for saving all
  SCH_XXX objects.

* Add function to SCH_FIELD to get the position of the field in the component
  not the position added to the component position which is what GetPosition()
  does.  This was required because saving the component field expects position
  of the field sans the position of the component.

* Remove public members from BITMAP_BASE object and fix all associated
  code.

* Fix the never ending coding policy violations found making these changes.
2016-07-11 15:48:46 -04:00
Wayne Stambaugh 3bdca9a821 Eeschema: schematic I/O manager bug fixes.
* Create a new dummy root sheet and screen when the schematic fails to load
  which was causing Eeschema to crash.

* Remove conversion from UTF8 to wxString left over from a previous change
  which hopefully will fix an OSX build error.

* Fix parsing of text objects to handle version 1 schematic files.

* Fix parsing of component fields to handle version 1 schematic files.

* Don't throw a parse error when a version 1 schematic file doesn't end with
  $EndSCHEMATC.
2016-07-07 09:09:32 -04:00
Wayne Stambaugh 4ed346ea64 Eeschema: initial schematic I/O plugin.
* Factor out PROPERTIES object from the PCB plugin code and move it into
  common so it can be used by both the Pcbnew and Eeschema plugins.

* Add schematic I/O plugin manager for loading and saving schematic and
  component library files.

* Add initial attempt at a parser for current schematic file format.  This
  parser will be infinitely more strict than the current parser which is very
  forgiving in what it parses.

* Make minor changes to the base bitmap class to support the new parser.

* Add find root sheet support to sheet object to allow fetching the root
  sheet from any sheet in the stack.
2016-07-06 05:22:56 -04:00