Checks for ratsnest enabled prior to calculating and displaying the
local/dynamic ratsnest. Calls the ratsnest clear from selection clear
Notably, it appears that the tool actions do not chain transitions for
the same event. So only a single action (first specified) will be
executed when an event fires unless the actions are executed by separate
tools.
Fixes: lp:1809752
* https://bugs.launchpad.net/kicad/+bug/1809752
It avoid including these extensions in a translatable string, thus avoid breaking filter
if the translation is incorrect (It happens sometimes).
See wildcards_and_files_ext.cpp for use.
If a page layout contains bitmaps and is used in all sheets of a hierarchy, and in the board editor,
the cross-probing from pcbnew to eeschema invalidate textures associated to these shared bitmaps,
when switching active sheets.
Usually a crash happens after switching or when closing editors.
As a workaround, I disabled bitmaps (therefore associated textures) cache.
Not optimal, but at least it avoid crashes.
The wrong class is called for the ctor of the wxConfigBase - this should
be a wxFileConfig, just like the bare new used to be.
Fixes: lp:1810002
* https://bugs.launchpad.net/kicad/+bug/1810002
Fix highlight not cleared by Pcbnew.
Fix highlight not cleared by Cvpcb (missing code).
Add comments. Remove a few now useless printf used for debug
When clicking on a empty area, clear any highligthed symbols
Fixes: lp:1809977
https://bugs.launchpad.net/kicad/+bug/1809977
While name and path fields would make more sense, this commit
encodes the nickname as an "opts" field so that older versions will
still read the preferences file.
This make the use of legacy canvas on GTK3 a default-off
advanced config. Legacy is substantially broken on GTK3
and is of basically no use at all to general users on this
platform.
If the program starts with legacy canvas in the config,
it is forced into a GAL mode, as otherwise it could happen
that the user is stuck and unable to get into pcbnew to change
the setting.
Fixes: lp:1803156
* https://bugs.launchpad.net/kicad/+bug/1803156
This can be used for "advanced" options which are for developers
to use for feature-flags and other configuration. Run time config
has some advantages over preprocessor defines:
* Can be changed without recompilation
* Sensitive to XDG_CONFIG_DIR, so flipping configs is easy
* Better compiler coverage (less conditionally compiled code means
less chance to break a different configuration). Also better
analysis coverage.
* Type safe config params
* Centralised documentation: it's in doxygen, in one place
No advanced config should be required by a general users. If a general
user does use one of these configs, it's probably because:
* There is a bug and one of these configs is a workaround
* A config in here is generally useful and should be moved into the
relevant application config and given UI.
For now, the config is read-only, and is read from the
"kicad_advanced" config file in the normal config dir.
While not technically allowed, overlapping polygons can be drawn in
pcbnew. Gerber polygons are strictly simple, however, so we need to
fracture prior to exporting to avoid invalid gerbers.
Rather than depend on proper unlocking for each exit, we move the
connectivity lock mutex into an RAII-type configuration that
automatically unlocks on exit.
Layer bit sets get chosen for the layer name, starting with the copper
layers and then the technicals. Additionally, multi-layer pads are
appended with an indicator that additional layer bits are set.
Fixes: lp:
* https://bugs.launchpad.net/kicad/+bug/
The fracture() call may result in zero polygons remaining, which will
cause failure in our tesselation routine, so we need to check whether
this is a valid POLYGON before re-tesselating.