It looks like this was overlooked by Jeff in 2020 not realizing eda_doc isn't built under eeschema but common in cc9ac37a0e
(cherry picked from commit f85251ef75)
The legacy symbol library plugin code was changed to escape symbol names
which broke the LIB_ID string comparison when checking to see if symbols
needed to be rescued. Escaping the LIB_ID names before comparison resolves
the issue.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
(cherry picked from commit a19490b097)
Previous use of instance was as an "override" of the default value.
This has changed to be used as the primary storage location for all
values. This means that we cannot clear the instance data when setting
a new value for all instances, instead we have to change the instance
data and the default value is superfluous
Fixes https://gitlab.com/kicad/code/kicad/issues/11439
(cherry picked from commit 1a70465927)
Pin names like "+V" were incorrectly parsed as doubles leading to broken
comparisons. These caused heap overflows when sorting pin tables
This corrects the comparison so that numeric sorts are only performed
when there is an actual number in the symbol segment. Also adds unit
tests for common error cases
(cherry picked from commit aac6f576c2)
Better to have both the single-pin error message and the non-driven
error message when an input pin is not connected than miss error
messages when the pin is connected to a blank net
Fixes https://gitlab.com/kicad/code/kicad/issues/10430
There was also a logic bug when the selected schematic was in a different
path than the current project and was already part of the current project.
The symbol library table reconciliation code was still run which was wrong.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11075
(cherry picked from commit e336a0e403)
Previously, coordinates were clamped to +- 60 inches. It makes no sense to
clamp them at plotter level: max cooed depends on the editor (schematic/board...)
Rename MAX_PAGE_SIZE_MILS to MAX_PAGE_SIZE_EESCHEMA_MILS and use it only for Eeschema.
Fixes#11196https://gitlab.com/kicad/code/kicad/issues/11196
(cherry picked from commit 21144481d2)
Do not use the symbol field string to populate the value and footprint
grid cells. The field strings may be empty because the symbol has not
been instantiated yet by entering a sheet. This fix makes an incorrect
assumption that the first instance value and footprint data in the symbol
is the same for all instances.
Note: this fix is incomplete because the value and footprint fields are
can now be different between sheet instances. The entire field
table editor design will need to be rethought because the current
grouping doesn't allow different value and footprint instance
changes.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11194
(cherry picked from commit b87fc45e33)
Now that we are dealing with individual connection elements that do not
update their connected elements as well, we can thread the update, just
being careful to guard any remaining updates (bus_enty/busLine) that
need reciprocal updating
Fixes https://gitlab.com/kicad/code/kicad/issues/10974