We used to store the symbol units of the current sheet and then
restore them, but we didn't handle the dangling states.
The new code uses a different strategy and just makes sure that if
any of the sheets are going to modify the current screen, the current
sheet gets to go last so that its modifications will "stick".
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15392
- Incremental extraction needs the newly created items. The modified
items are already set in the connection graph but the newly created
items don't exist yet, so we need to add those explicitly
- Bus parents need to ensure that the bus children exist because we
iterate on the updates from the top of the graph down
Using a boolean argument just leads to a lot of trailing booleans in the
function calls and is not user friendly. Instead, introduce PostAction()
to send an action that runs after the coroutine (equivalent to passing
false or the default argument), and leave RunAction as the immediate
execution function.
The connection graph should only be updated within the commit structure
because this is the only time the connectivity should be changed. We
want any connectivity changes to be included in the commit as well, so
this should be stored prior to the undo/redo list mods
We don't really control when these are called, so best not to assume
we've finished initialization of the frame/screen/document/whatever.
Possible fix for KICAD-KY.
- Expand tree and highlight object selected with net highlight tool.
- Expand tree and highlight object that are currently highlighted with the
selection tool.
- Use more descriptive object text rather than menu entry text for tree
strings.
- Rebuild tree on unit changes.
[ADDED]: A panel to the schematic editor that allows quick access to all
of the items connected to the currently highlighted net.
This is an initial swag at implementing a full net navigator feature. For
now it only shows the currently highlighted net nodes. The incremental
net list advanced setting must be enabled in order to use this feature due
to performance reasons. There are still some issues with saving the panel
position which will be addressed in the future.
Initial code for serializing wxAuiPaneInfo settings to and from JSON have
be implemented.
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).