Right click is a pointing operation combined with a request for the
context menu. We need to highlight the user's intended object when they
have moved their mouse to a new element instead of showing the context
menu for the selected object.
However, in cases where the selection is difficult to make, it is
sometimes helpful to select the item first, then right-click. In these
cases, we keep the selection where the mouse remains inside the selected
object's bounding box.
We have forbidden lists maintained in 3 separate locations. This causes
a bit of confusion as to which is correct.
This makes the list uniform but remains to place the character set in a
single location.
When placing a new component in the schematic, this allows the user to
iterate through all units in the selected component without re-opening
the choose part dialog. It also allows the optional addition of
multiple copies of the same component to be placed in the schematic.
Fixes: lp:1806217
* https://bugs.launchpad.net/kicad/+bug/1806217
Adding a field to a selection changes the bounding box and count for
rotation. This can cause odd offsets when the field is rotated against
the selection center rather than the bounding box as well as with the
component.
Fixes: lp:1849078
* https://bugs.launchpad.net/kicad/+bug/1849078
The previous fix for optimizer breakout length calculation was providing
better scores to longer traces rather than longer breakouts as intended.
This limits the length scoring to breakout only.
The oval clearance adds an edge on the 0-length side of a circular oval.
This is not needed and can affect the fill algorithm. Instead, we treat
round ovals as circles for pad polygons
Fixes: lp:1849846
* https://bugs.launchpad.net/kicad/+bug/1849846
(cherry picked from commit 57f0f88552)
The constrained draw was constraining the polygon size to fit the
existing points rather than extending the existing points to fit the
user's intent.
This adds a 90° double-joint for the completion polygon that allows the
user to complete common constrained polygons visually based on the
preview with a double-click to finish.
BLOCK elements in DXF are re-usable bits that are useful when editing
the file but should not be shown when importing the model. This skips
all references except those that exist in the default "*Model_Space".
This block is required in each DXF file and cannot be renamed.
Fixes: lp:1790821
* https://bugs.launchpad.net/kicad/+bug/1790821
Changing common settings in EDA_BASE_FRAME may segfault for frames that
don't implement tool manager yet (simulator)
Fixes: lp:1849492
* https://bugs.launchpad.net/kicad/+bug/1849492
deque structures have higher overhead than vectors. Not usually
problematic, but with hundreds of thousands of characters each with only
a few strokes, the overhead becomes dominant.
The break wire command will break all wires at a point. If there are
multiple crossing wires, we need to check to see if a junction might be
required to reflect the new connection.
Fixes: lp:1848450
* https://bugs.launchpad.net/kicad/+bug/1848450
Flipped footprint pads may report their "primary" layer as not the front
layer in high contrast. We need to check whether the board item for
snaps is visible on the active layers.
Fixes: lp:1847877
* https://bugs.launchpad.net/kicad/+bug/1847877
In ZONE_CONTAINER( ZONE_CONTAINER& aOther ), the net info was set before zone type and layer were set.
So the net info was always set to ORPHAN net, instead of set to aOther net info.
Especially, it broke undo/redo function.
Fixes: lp:1840727
https://bugs.launchpad.net/kicad/+bug/1840727