Create dialog and code to allow legacy schematic symbols to be remapped
from the old library path look up method to the new symbol library table
method by using the following steps:
1) Create a project symbol library table containing all of the symbol
libraries defined in the old library look up list not found in the
global symbol library table.
2) Map each symbol to the correct symbol in the symbol library table
if possible.
Recreate library link to symbols so look up method can be converted to
symbol library table properly.
Add function to SCH_COMPONENT to link library symbols using the symbol
library table.
Move the dialog layout refresh from the ctor to TransferDataToWindow which
is called by event after the dialog object is constructed. This was causing
the 3D view panel to be drawn incorrectly on windows builds.
Remove unnecessary wxT() macros.
Fixes lp:1665888
https://bugs.launchpad.net/kicad/+bug/1665888
Add loading symbol library table code to schematic PROJECT object.
Fix minor issues with loading global symbol library table.
Add default symbol library path environment variable to the environment
variable list and change the variable name to KICAD_SYMBOL_DIR.
Add code to SCH_SCREENS to test if all library nicknames of the symbol
library IDs are empty.
Remove unnecessary KICAD_USE_SCH_IO_MANAGER build option.
Independent drawing functions (that don't expect any particular state to
be set up fo them) on the GAL need to reset the GAL properties they
use. This adds GAL::ResetTextAttributes() to make this easier.
This is important, as failing to reset mirroring can cause asserts in
OpenGL.
This is used in the Ruler tool (which previously did it one attribute at
a time) and also the Arc layout assistant, which previously failed to
reset mirroring.
Also reset on GAL construction, as these members appear to be
uninitialised.
non ascii7 filenames of zip files issues are fixed.
There are still issues with non ascii7 filenames inside the zip archives (especially when a zip archive was created on Windows)
Factor out the FP_LIB_TABLE specific content from FP_TBL_MODEL into a new
LIB_TABLE_GRID class that can be used for any library table grid mix in.
Create new FP_LIB_TABLE_GRID object for the footprint library edit dialog.
Add method GetEnvVariables() to return any environment variables found in
a LIB_TABLE object.
Fix if statement logic to ensure the unit number is never set to zero.
Add logic to the legacy schematic plugin to automatically convert any
schematic files that have components with a unit setting of zero. Set
the schematic modified flag so that the user will be notified of a
changed schematic.
Add a user warning when the schematic parser fixes the bug and sets
the file modified flag.
Fixes lp:1677282
https://bugs.launchpad.net/kicad/+bug/1677282
These were backwards since internal angles are CCW due to the inverted Y
axis.
The hotkeys have NOT changed. This means 'R' is now clockwise and
'Shift+R' is anti-clockwise. This is the same as EEschema, but not the
same as Legacy mode.
This is required as the OpenGL GAL doesn't support mirrored
text, and if the state is not cleared after painting other mirrored
text, this is what is attempted.
Fixes: lp:1677210
* https://bugs.launchpad.net/kicad/+bug/1677210
This tool is currently very rudimentary. I pushed it because I need to
collect responses from it from users with diverse graphics
configurations, so I want the tool to be in the nightly builds.
This affects no KiCad code.
This bug was actually here before the new component chooser this time;
I'm not sure what the purpose of this error message was since it is
being displayed in a non-error state. Maybe a copy/paste bug from when
Delete Component was changed to use the main component chooser?
- In the listing, display alias names in italics
- In the info panel, display per-alias description correctly, as well as
root description
Fixes: lp:1676190
* https://bugs.launchpad.net/kicad/+bug/1676190