Always use full sheet paths when storing sheet instances. Partial sheet
paths cannot be full resolved resulting in lost page numbers when renaming
sheet file name.
Fixes#9782
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync. All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.
Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782
Bitmaps are now identified by an enum class instead of by pointers.
Bitmap loading and caching is now handled by a class in common, and
we no longer compile most bitmaps into the binary, so there is no
longer a bitmaps static library.
Instead, bitmaps are archived to a .tar.gz file which is installed
in ${KICAD_DATA}/resources/images.tar.gz
The source PNGs are checked in to Git as the original CPP files were,
so that people can build without the required dependencies to convert
SVGs to PNGs.
Initial support is also added for dark theme icons, although this
is not yet exposed in the GUI.
Stubs are present for multi-resolution image resources, but this is
not fully-baked yet and could use some refinement.
- update hierarchy navigator after any modifications to the SCH_EDIT_FRAME
- do not generate ghost selection events after updating hierarchy tree
- use Human Readable path in SCH_EDIT_TOOL::EditPageNumber
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5760
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects. It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic). This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet. This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references. It also allows the root schematic from one project
to be uses as a sub-sheet in another project.
When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs. This is done to ensure there
are no sheet path instance clashes between projects. That being said,
there are no checks for this. It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
SCH_SHEET objects can only have another SCH_SHEET object as a parent
or nullptr for the root sheet so overload EDA_ITEM::SetParent() to
prevent the parent from being set to another type of object and add
some checks to the root sheet code just in case someone gets clever
and attempts to bypass the overloaded SetParent() call.
Don't try to use complex algorithms taking into account default
margins, line-widths and pen-widths (especially when they differed
between label types). We now use the (user-controlled) text
offset ratio to determine the margins (from the center-point of
the attached line).
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format. Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.