Commit Graph

83 Commits

Author SHA1 Message Date
Jeff Young a3d83cdb6d Pass symbol netlist from Field Properties dialog.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15806
2023-10-02 23:41:06 +01:00
Seth Hillbrand bdb7b99fc8 Don't destroy the pin cache in symbols
SCH_PIN pointers are used through KiCad and removing them without a
global refresh risks crashes.  A safer approach is to simply reuse the
SCH_PIN structures, updating the data to the revised library

Fixes https://gitlab.com/kicad/code/kicad/-/issues/15715
2023-09-22 11:28:30 -07:00
Mike Williams e1d5089c74 Symbol Fields Table: handle recursive sheet add/delete/update 2023-08-14 14:19:26 -04:00
Mike Williams 1c52a60270 Symbol Fields Table: API cleanups for non-modal window 2023-08-14 14:19:26 -04:00
Mike Williams ab1dccd6b3 Symbols: remove dead code 2023-08-09 14:32:06 -04:00
Mike Williams bdecdce1b4 Exclude from Sim: move from field to attribute 2023-08-08 12:36:36 -04:00
Mike Williams 8fb316f995 Symbols: add ${EXCLUDE_FROM_SIM} variable to match the other attributes 2023-08-01 14:33:30 -04:00
Youbao 4cb993d872 ADDED: Cadence Allegro PCB Designer netlist exporter 2023-06-28 22:47:30 +00:00
Jeff Young e7ee6e1f26 Modified flags are handled by SCH_COMMIT. 2023-06-25 16:01:35 +01:00
Jon Evans d4b7144448 Properties: expose symbol attributes
Flip polarity of exclude-from-BOM and -board for symbols
to match that of footprints and match the GUI display.
2023-06-24 22:03:06 -04:00
Mike Williams a24c55affe PCB Fields: fix up python, API
Remove SetFields from both symbol and footprint, it doesn't handle
mandatory fields and is unlikely to ever be safe.
2023-06-20 18:34:52 +00:00
Mike Williams 9f62e88477 Symbol Fields Table / BOM Export: handle variable resolution 2023-05-08 10:59:13 -04:00
Mike Williams 5d116245c6 sch_symbol: always require sheet path for text variable resolution 2023-05-06 14:30:06 -04:00
Jeff Young b41d446f58 Fix a bunch more issues with sheetpaths and allowExtraText.
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.

There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.

Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
2023-05-05 17:23:52 +01:00
Wayne Stambaugh fb6b8eaeea Don't include power symbol pin when exporting netlist.
The netlist exporter was never updated to exclude symbols that are
tagged as power symbols.  Only the legacy power symbol name prefix
('#') was used as the power symbol check.  Power symbols no longer
require the '#' name prefix.
2023-05-05 08:53:29 -04:00
Jeff Young ea59d583d5 ADDED exclude-from-simulation property to text items and textboxes. 2023-04-09 19:03:36 +01:00
jean-pierre charras 8b144539e8 DIALOG_LABEL_PROPERTIES, add global label: better filtering of candidates.
The list of candidates (names) must be restricted to existing global labels
and symbols creating a global net name: power symbols having only one power
input pin (a power output does not create net name).
Fixes #14319
https://gitlab.com/kicad/code/kicad/issues/14319
2023-03-16 15:31:39 +01:00
Mike Williams c8fdac7abe Schematic: correctly resolve global power nets using sheet variables
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/7445
2023-03-08 11:52:43 -05:00
Jon Evans 7b3fd2113c Improve sheet rendering performance
- Cache font markup parsing
- Cache SCH_SYMBOL::GetOrientation
- Don't construct new strings each time in GetDefaultFieldName
2023-03-05 17:41:46 -05:00
Jon Evans c530bdb5a1 Rename GetSelectMenuText to GetItemDescription
This descriptive text is used for many more things than
just the select menu these days.
2023-01-11 22:27:44 -05:00
Seth Hillbrand f99e374559 Make DNP more visible
Adds red cross to the DNP display.  Allows showing the DNP even when
plotting black/white

Fixes https://gitlab.com/kicad/code/kicad/issues/13456
2023-01-09 15:31:50 -08:00
Wayne Stambaugh d99e09014b Rename SYMBOL_INSTANCE_REFERENCE to SCH_SYMBOL_INSTANCE. 2023-01-04 15:39:50 -05:00
Wayne Stambaugh 78e2f0fd4d Sheet instance handling improvements. 2022-12-26 08:30:03 -05:00
Jeff Young 24786fe0e9 Fix multi-unit symbol bugs.
1) SPICE pins need to include all units
2) Already-seen-unit-x needs to be reset when getting netlist again.

Fixes https://gitlab.com/kicad/code/kicad/issues/13164
2022-12-16 13:57:46 +00:00
Jeff Young 05b9836f60 Remove ugly hack of passing SCH_SYMBOL as parent of LIB_FIELD array.
Also adds simulation model inference to Symbol Editor's Simulation Model
Editor, and adds write-back from both Simulation Model Editors to their
parent Symbol Fields Editor dialogs.

Fixes https://gitlab.com/kicad/code/kicad/issues/12505
2022-12-09 20:24:25 +00:00
Jeff Young 8931e55dd2 Templatize MigrateSimModel() so it can be used on LIB_SYMBOLs as well.
Fixes https://gitlab.com/kicad/code/kicad/issues/13080
2022-12-08 23:57:43 +00:00
Jeff Young b9287968d6 Update symbol default prefixes after updating instance data.
Also moves the sim model fixups after the instance data updating as
it uses the prefixes.
2022-12-07 01:34:56 +00:00
Wayne Stambaugh 0a62c17040 Remove schematic symbol value and footprint field instance data.
https://gitlab.com/kicad/code/kicad/-/issues/12933
2022-11-30 11:47:13 -05:00
Mikolaj Wielgus f5ebd6fb47 Remove unused SCH_SYMBOL::GetAllPins() 2022-11-25 05:38:21 +01:00
Wayne Stambaugh 4a27d856f7 Move schematic sheet instance information into file sheet definition.
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.

Setting and getting sheet page numbers must now be performed using a
sheet path.  This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
2022-11-22 16:45:38 -05:00
Wayne Stambaugh a11c40197f Expunge default symbol instance from schematic file format.
Now that importing hierarchical sheets "properly" imports instance data,
the default symbol instance setting doesn't have any meaning.
2022-10-04 15:42:41 -04:00
Seth Hillbrand e055302a3c Allow printing backgrounds prior to foreground
Eeschema shows background fills on a different z-level than the rest of
the symbols/elements.  Print the backgrounds prior to the foregrounds in
order to preserve this view for print output

Fixes https://gitlab.com/kicad/code/kicad/issues/12559
2022-10-02 13:23:54 -07:00
Wayne Stambaugh 2b387ae9c3 Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Added project name to instance data to improve the readability of the
schematic file format.  It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-10-02 15:06:42 -04:00
Wayne Stambaugh 979b4a4eb7 Revert "Move schematic symbol instance data back into symbol definition."
This reverts commit 7984e114db.
2022-09-29 15:33:23 -04:00
Wayne Stambaugh 7984e114db Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-09-29 17:47:57 +00:00
Jeff Young 64a6fc0fd4 Push UNITS_PROVIDER down into a low-level mixin.
This allows us to also construct cheap UNIT_PROVIDERs for specific
tasks when necessary.
2022-09-19 17:10:59 +01:00
Seth Hillbrand 524b129c64 ADDED: Support for explicit DNP field
Dims elements shown as DNP.  Adds property `dnp` to explicitly denote
parts that should not be populated. These parts are not included in X/Y
files
2022-09-16 22:26:16 +00:00
kliment b97f9ea329 Add support for symbol unit display names in eeschema and symbol editor 2022-09-14 22:11:37 +00:00
Jeff Young b1e5cb5a56 ADDED ${SYMBOL_DESCRIPTION} and ${SYMBOL_KEYWORDS}.
Fixes https://gitlab.com/kicad/code/kicad/issues/9783
2022-09-03 19:29:59 +01:00
Wayne Stambaugh 4c096fee15 Eeschema: fix crash when attempting to edit missing library symbol.
Disable the edit symbol buttons in the symbol properties dialog when
there is no library symbol to edit.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/11318

(cherry picked from commit 5afeb45a84)
2022-09-02 16:25:34 -04:00
Jeff Young f17a865593 Move EDA_ITEM hitTest to BOX2I. 2022-08-31 17:18:45 +01:00
Jeff Young 2dc6300501 Move EDA_ITEM bounding boxes to BOX2I. 2022-08-31 10:16:55 +01:00
Jeff Young 5679b9dbdc Remove a few EDA_RECT instances. 2022-08-31 01:22:49 +01:00
Wayne Stambaugh 7c6d9f67f9 Eeschema: fix broken instance data when adding new symbol.
Pass the current SCHEMATIC object pointer in SCH_SYMBOL ctor so that
newly created symbols will update the current instance data on creation
when the current sheet instance is being displayed.

This is a better fix for the master branch and cherry-picking from 6.0
was a mess.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12190
2022-08-26 13:35:49 -04:00
Marek Roszko e0f28fc4e1 Replace wxFindReplaceData with our own container
By dropping the flags, we can be strict with options.
Also it makes future usage of search functionality a little more "UI" framework independent
2022-08-23 22:16:51 -04:00
Mikolaj Wielgus 6fad25f8ed Allow mapping sim model pins to arbitrary string symbol pin numbers
This change removes the incorrect assumption that symbol pin numbers are
integers and are the same as indexes in the vector storing the symbol
pins.

"~" is now used to denote a floating sim model pin.
2022-08-22 08:13:26 +02:00
Jeff Young 4f0136db3b Attempt to fix std::initializer_list lifetime issue. 2022-08-21 20:54:41 +01:00
Jeff Young aa2ad3b44c Move KICAD_T[] to std::initializer_list<KICAD_T>. 2022-08-20 10:28:11 +01:00
Mikolaj Wielgus 978f01553b Sim Model Editor: Serialize models in fields
Implemented serialization and deserialization of models in symbol fields
through the SIM_VALUE class. We don't carry the Spice legacy of
case-insensitive suffixes, instead we conform to the SI standard (i.e. M
is Mega, not milli, P is peta, p is pico).

Parameter grid value validation is implemented by simply not allowing
any characters that will make the value invalid (instead of highlighting
the field in a red color). This will likely be changed at some point in
the future.
2022-07-30 02:25:34 +00:00
Marek Roszko a8505d9c76 SEARCH_RESULT -> INSPECT_RESULT
To fix the name squatting it's doing for future functionality
2022-07-29 20:01:10 -04:00