The zoom window toolbar button is on the right toolbar separated from the
other zoom buttons on the top toolbar. Move the zoom window button to the
top toolbar beside the other zoom buttons.
Before the refactor library browser display Bezier curves correctly only
once, at other times they were just straight lines or crashed the
application.
The symbol library header was setting the text thickness using the
last line thickness setting which is incorrect so use the default
thickness when creating new text objects.
Fixes lp:1635344
https://bugs.launchpad.net/kicad/+bug/1635344
- Removed ability to generate BOM to file
- Removed Save/Cancel window when closing table
- No longer updates table <after> table is closed
- Bugfix for field names (previously comparison was case insensitive)
- Allows grouping of matched components
- Bulk edit of components in a spreadsheet window
- User can choose to save / undo changes
- All changes are pushed to the undo stack in a single operation
- Export table to HTML / CSV output
Sadly, each unit of a component can have its own unique fields. This
change finds the last non blank field and records it. Last guy wins
and the order of units occuring in a schematic hierarchy is variable.
Therefore user is best off setting fields into only one unit. But this
scavenger algorithm will find any non blank fields in all units and use
the last non-blank field for each unique field name.
Fixes lp:1471417
https://bugs.launchpad.net/kicad/+bug/1471417
This reverts commit 0a8a659ff7.
The patch is incorrect, as it removes the FP chooser drop-down list.
I cannot reproduce the crash with the patch reverted, so there must
have been something specific to my configuration at that time.
Create dialog and code to allow legacy schematic symbols to be remapped
from the old library path look up method to the new symbol library table
method by using the following steps:
1) Create a project symbol library table containing all of the symbol
libraries defined in the old library look up list not found in the
global symbol library table.
2) Map each symbol to the correct symbol in the symbol library table
if possible.
Recreate library link to symbols so look up method can be converted to
symbol library table properly.
Add function to SCH_COMPONENT to link library symbols using the symbol
library table.
Add loading symbol library table code to schematic PROJECT object.
Fix minor issues with loading global symbol library table.
Add default symbol library path environment variable to the environment
variable list and change the variable name to KICAD_SYMBOL_DIR.
Add code to SCH_SCREENS to test if all library nicknames of the symbol
library IDs are empty.
Remove unnecessary KICAD_USE_SCH_IO_MANAGER build option.
Fix if statement logic to ensure the unit number is never set to zero.
Add logic to the legacy schematic plugin to automatically convert any
schematic files that have components with a unit setting of zero. Set
the schematic modified flag so that the user will be notified of a
changed schematic.
Add a user warning when the schematic parser fixes the bug and sets
the file modified flag.
Fixes lp:1677282
https://bugs.launchpad.net/kicad/+bug/1677282
This bug was actually here before the new component chooser this time;
I'm not sure what the purpose of this error message was since it is
being displayed in a non-error state. Maybe a copy/paste bug from when
Delete Component was changed to use the main component chooser?