A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
The netlist exporter was never updated to exclude symbols that are
tagged as power symbols. Only the legacy power symbol name prefix
('#') was used as the power symbol check. Power symbols no longer
require the '#' name prefix.
- SCH_SYMBOL::GetMsgPanelInfo(): slighly change the displayed lines to allow
longer strings in Description and Keywords
- panel_setup_rules_help.md: fix incorrect html link (URI), creating ERR 404
The list of candidates (names) must be restricted to existing global labels
and symbols creating a global net name: power symbols having only one power
input pin (a power output does not create net name).
Fixes#14319https://gitlab.com/kicad/code/kicad/issues/14319
This iterated over all pins to find the pin after a given item. Because
out pattern is consistently to iterate in the outer loop, this means
that we were an O(n^2) loop for the pins just to find their names. This
affected very large parts (e.g. FPGAs) when switching sheets to display
EDA_ITEMs are responsible for giving their parent a crack at it if
they failed to resolve it. This recurses all the way up to the schematic/
board, and then to the project.
Cross-reference handling is also move to the EDA_ITEMs. It must be done
before bubbling up so that we don't end up in loops. (The aDepth parameter
will break the loop, but without having done anything useful.)
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
Eeschema shows background fills on a different z-level than the rest of
the symbols/elements. Print the backgrounds prior to the foregrounds in
order to preserve this view for print output
Fixes https://gitlab.com/kicad/code/kicad/issues/12559
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472