Commit Graph

14 Commits

Author SHA1 Message Date
Dick Hollenbeck 4578ea8b9e 1) Add 32 Cu Layers.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
   The old Cu stack required knowing the count of Cu layers to make
   sense of the layer number when converting to many exported file types.
   The new Cu stack is more commonly used, although ours still gives
   B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
   meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
   can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
   You will need to convert to the format immediately, *.kicad_pcb and
   *.kicad_mod (=pretty) since legacy format was never going to know
   about 32 Cu layers and additional technical layers and the reversed Cu
   stack.
2014-06-24 11:17:18 -05:00
Lorenzo Marcantonio 3f2c0e1a8d TRACK/SEGVIA cleanup
- SEGVIA becomes VIA
- Drill size moved from TRACK to VIA
- Removed shape from TRACK, becomes ViaType in VIA
- GetTrace becomes GetTrack, for uniformity
- Some minor constification and typo fixes
2014-04-25 08:00:04 +02:00
Maciej Suminski 75026d8754 Renamed BOARD_CONNECTED_ITEM::GetNet() -> GetNetCode()
Renamed BOARD_CONNECTED_ITEM::SetNet() -> SetNetCode()
Added BOARD_CONNECTED_ITEM::GetNet() for accessing NETINFO_ITEM* of a given item.
Fixed module editor crash when launched to edit a module from a PCB.
Replaced some BOARD::FindNet( item->GetNet() ) calls with BOARD_CONNECTED_ITEM::GetNet().
2014-02-25 11:40:34 +01:00
Maciej Suminski 7f6bc781aa Upstream merge. 2014-01-28 10:43:55 +01:00
jean-pierre charras 3354bdde05 Pcbnew: fix bug #1272714 . Code cleanup: use 2 different enums for pad shapes and pad drill shapes. Remove never used pad shape. 2014-01-26 15:20:58 +01:00
Maciej Suminski 8a4e723504 NETINFO_ITEMs are not stored in a vector anymore, instead they are held in a unordered_map. Now, the net codes may be not consecutive. There is another way for assigning net codes (using a static int that holds a possible empty net code and a function that makes sure it is not used [getFreeNetCode()]).
Removed some unused fields (NETINFO_ITEM::m_NbNodes, m_NbLink, m_NbNoconn, m_Flag).
2014-01-16 14:20:51 +01:00
Maciej Suminski 654e7e556e Removed D_PAD::SetNetname() function and D_PAD::m_Netname, D_PAD::m_ShortNetname fields.
D_PAD::GetNetname() and D_PAD::GetShortNetname() were moved to BOARD_CONNECTED_ITEM. Now they use the net name stored in NETINFO_ITEM.
Moved some one-line functions from class_board_connected_item.cpp to class_board_connected_item.h.
Added a copyright notice, moved Doxygen comments from class_board_connected_item.cpp to class_board_connected_item.h.

I have some doubts if changes introduced pcbnew/dialogs/dialog_pad_properties.cpp do not break anything, but I could not find a test case that breaks the pcbnew.

Performed tests:
- changed pad's net name from empty to existent - ok, name was changed
- changed pad's net name from empty to nonexistent - ok, error message is displayed, net name stays empty
- changed pad's net name from existent to empty - ok, net name became empty
- changed pad's net name from existent to nonexistent - ok, error message is displayed, net name is not changed
- (re)reading netlists, including net changes - fine, changes are applied, but empty nets are still kept
- loaded pcbnew/pcad2kicadpcb_plugin/examples/CK1202_V1.pcb to test P-CAD import plugin - ok, net names are correct
- imported an Eagle 6.0 board (Arduino Uno; http://arduino.cc/en/uploads/Main/arduino_Uno_Rev3-02-TH.zip) then saved in .kicad_pcb format and reloaded - ok, net names are correct
- saved demos/video/video.kicad_pcb in legacy format and then loaded it again - ok, net names are correct
2014-01-14 10:41:52 +01:00
Lorenzo Marcantonio b525e3be55 Factored out text anchor drawing
More layer classification cleanup
2013-04-09 18:00:46 +02:00
Lorenzo Marcantonio 00f0e27851 Factored layer utility functions: classification, layer flip and mask flip 2013-04-05 21:04:58 +02:00
Wayne Stambaugh 7d0ec1a138 More encapsulation work.
* Complete encapsulation of the MODULE class.
* Complete encapsulation of the EDA_TEXT class.
* Encapsulate most of the ZONE_CONTAINER class.
* Add pcbcommon library as a dependency for reSWIGging the scripting
  support.  This should cover most dependency cases.
2013-03-18 15:36:07 -04:00
jean-pierre charras 5fc382df85 Pcbnew: Partial merge from pcad2kicad (from Alexander Lunev). Fix an old bug related to pads with offset: sometimes the connection to a zone was not detected. 2013-03-09 20:36:31 +01:00
jean-pierre charras 89f590a1fc Pcbnew: Pcad2kicad: remove dead code. 2013-02-13 18:19:46 +01:00
Wayne Stambaugh 4d465ec8a0 Configuration and compile documentation improvements.
* Improve the stable and testing build version option logic.
* Use CMake FindPythonInterp to configure the Python interpreter.
* Use Python interpreter to determine the system Python module install
  path if not already defined on the command line.
* Add header symbol checks for asinh(), acosh(), and atanh().
* Add test source to check for isinf() which can be defined as a C++template.
* Replace conditional compile on windows systems for aXXXh() with CMake
  configuration tests.
* A few minor MSVC compile fixes.
* Fix incorrect python environment string in fixswigimports.py
* Create a separate document for KiCad CMake build options.
* Create a separate how to compile KiCad on Windows document.
2013-02-10 19:41:49 -05:00
Alexander Lunef 40f4304b2f Pcbnew: Add pcad2kicad pcb plugin, to import PCAD boards ( .pcb ASCII data file PCad 2000 format ) from Alexander Lunef 2012-12-29 10:54:25 +01:00