This method is added for scripting purposes, to be able to query
specific board layer names thru a board object.
If no board specific layer name is found, it will fallback to
standard layer names.
* Add test to CMakeLists.txt to verify wxPython is installed when
KICAD_SCRIPTING_WXPYTHON=ON.
* Add test to make sure wxPython version major and minor numbers match
the version of wxWidgets found.
* Add code to set the correct version of wxPython to the python scripting
initialization code.
* Minor code simplification in Pcbnew KIFACE main window creation.
Rename eeschema/dialogs/dialog_sch_find.fbp to dialog_schematic_find_base.fbp, to be consistent with other dialogs.
Pcbnew run from the project manager: add menu Save Copy As..., which is the same command as Save As ... in stand alone mode, but with the constraints of a project (no cwd change, no board filename change, and keep project settings)
* Using a Web navigator embedded in Kicad can create security issues in Kicad.
* The web kit is not always easily available on Linux.
* There is now a tool in kicad fp lib wizard to list and select the .pretty libs available on Github Kicad repo (When the kicad plugin is selected, this tool can download and make a local copy of these libs)
However, using -D KICAD_USE_WEBKIT=ON when invoking cmake still build the embedded web viewer.
These settings are now not common to the board editor, because the footprint editor can be run outside the board editor.
download_boost.cmake: ignore .htm* files when installing boost. They are not used, and often have a very very long (and stupid) name which sometimes creates issues.
* Fix -Woverloaded-virtual warning in DIALOG_LIB_NEW_COMPONENT class
definition.
* Make EDA_ITEM::Matches( const wxString& wxFindReplaceData& ) protected
since it's a helper function that should only be called by derived objects.
* Check to see if image handler is already initialized to prevent warning
on debug builds.
* Change LIB_PART destructor message output to use wxLogDebug for debugging
on windows builds.
* Minor code cleaning and coding policy fixes.
* Delete Single Pad Net option does not delete the net if a zone use this net (i.e. is attached to this pad).
* pcb_parser accept now negative netcodes in zones (can happen with old files, which previously could crash Pcbnew)
* pcb_parser accept now files with incorrect or missing net count (can happen with old files, which previously could crash Pcbnew)
* if a zone has a non-existent net name it now keep this net name, and DRC detect it (previously, the net name was lost, and the DRC did not tected this issue).
* Drc test: now detect a "dead" net, i.e. a net with 0 pads, but still used by a zone. It happens easily after a schematic modification, when a net disappears or is renamed.