When a rescue library already existed, the disabled writing of legacy
symbol library table entries prevented the rescue library from being
updated.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11897
(cherry picked from commit 4e7b5b9784)
The original decision to escape the legacy symbol library names results
in them being escaped every time they are opened which cause the curly
braces '}' from the original escaping to be escaped on subsequent
openings. This resulted in the symbol library names in the rescue
library not matching the library ID in the schematic.
This fix is likely to have other corner case bugs given the potential
for escaped characters in legacy symbol libraries. Given that we now
have escaped rescue libraries in play, removing the escaping will only
result in more issues so we will have to fix the corner cases as we go.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
"Highlight on PCB" and "Select" - "Items in Same Hierarchical Sheet"
actions were extended to select items on subsheets too.
"Highlight on PCB" now uses a proper full sheet path, allowing it to
work in subsheets.
Fixes https://gitlab.com/kicad/code/kicad/issues/11493
It looks like this was overlooked by Jeff in 2020 not realizing eda_doc isn't built under eeschema but common in cc9ac37a0e
(cherry picked from commit f85251ef75)
The legacy symbol library plugin code was changed to escape symbol names
which broke the LIB_ID string comparison when checking to see if symbols
needed to be rescued. Escaping the LIB_ID names before comparison resolves
the issue.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
(cherry picked from commit a19490b097)
Previous use of instance was as an "override" of the default value.
This has changed to be used as the primary storage location for all
values. This means that we cannot clear the instance data when setting
a new value for all instances, instead we have to change the instance
data and the default value is superfluous
Fixes https://gitlab.com/kicad/code/kicad/issues/11439
(cherry picked from commit 1a70465927)
Pin names like "+V" were incorrectly parsed as doubles leading to broken
comparisons. These caused heap overflows when sorting pin tables
This corrects the comparison so that numeric sorts are only performed
when there is an actual number in the symbol segment. Also adds unit
tests for common error cases
(cherry picked from commit aac6f576c2)
Better to have both the single-pin error message and the non-driven
error message when an input pin is not connected than miss error
messages when the pin is connected to a blank net
Fixes https://gitlab.com/kicad/code/kicad/issues/10430
There was also a logic bug when the selected schematic was in a different
path than the current project and was already part of the current project.
The symbol library table reconciliation code was still run which was wrong.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11075
(cherry picked from commit e336a0e403)
Previously, coordinates were clamped to +- 60 inches. It makes no sense to
clamp them at plotter level: max cooed depends on the editor (schematic/board...)
Rename MAX_PAGE_SIZE_MILS to MAX_PAGE_SIZE_EESCHEMA_MILS and use it only for Eeschema.
Fixes#11196https://gitlab.com/kicad/code/kicad/issues/11196
(cherry picked from commit 21144481d2)