Avoid O(N^2) by spatial sorting, don't run checks if the bounding boxes
don't overlap.
A second copy is ordered by type to help classes that only want to check
a few types having to walk the whole list.
(cherry picked from commit b7b64d959f)
It appears that in our zeal to prevent file changes when saving shared
schematics, we (I) clobbered saving relative symbol instance data paths
to the clipboard. This has be restored along with setting the correct
symbol unit for relative clipboard paths.
Fixed a serious issue with KIID_PATH::MakeRelativeTo() where the original
path was not restored when the incremental KIID object test fails. This
also included a minor optimization using the actual KIID object for
comparison instead of converting it to a string and then comparing the
string.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15981
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
Shared schematics can have a root sheet instance when opened with the
schematic editor in stand alone mode. This would cause a crash when
opening the shared schematic in a project where it was shared because
the root instance was trying to be saved in the normal sheet instance
data which is not valid.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13102
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.
Setting and getting sheet page numbers must now be performed using a
sheet path. This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
Also moves most navigation code to SCH_NAVIGATION_TOOL.
Also changes page number href to anchor syntax ('#foo').
Also adds hypertext processing to SCH_TEXTBOXes.
Also adds combobox with schematic pages to text properties dialog.
When reading sheet fields, we need to maintain a consistent order for
the mandatory fields as they are dereferenced by place. We force this
during the `SetFields()` call.
(cherry picked from commit 8385ce3021)
Always use full sheet paths when storing sheet instances. Partial sheet
paths cannot be full resolved resulting in lost page numbers when renaming
sheet file name.
Fixes#9782
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync. All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.
Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782