If removing unused via annular ring option is enabled on a layer, then the via will have the ring if both:
- Via center is not inside a rule area with "Keep out copper fill" flag set
- Highest-priority zone the via hole intersects with has the same net
Pads will be flashed if:
- Pad center is not inside a rule area with "Keep out copper fill" flag set
- Highest-priority zone at the pad center has the same net
Fixes https://gitlab.com/kicad/code/kicad/issues/12964
Don't use the value field when adding Eagle part attributes to a symbol.
This issue was cause by using a mandatory symbol field ID instead of
using the next available field ID when adding new fields to as symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13468
1) Special case doesn't work for polygons with holes
2) Fix special case to handle intersecting lines where neither end is
in the polygon.
Note that only (1) is required for the bug below. (2) was just
discovered while implementing (1).
Fixes https://gitlab.com/kicad/code/kicad/issues/13779
Remove some useless spacers, and do not force some widgets to have a to
large size (by removing empty areas).
Work in progress: one panel is still too big.
The ngspice manual does not indicate that there is any default
model type. This change ensures we get a `level=xy` written out to the
.model line when we select a HiSIM_HV model.
- generate .model lines in spice netlist for all device types that need
one
- add "level=<n>" to .model line for non-default model levels. This is
necessary to allow more sophisticated models to be used, and some
devices *always* need a level specified (e.g. JFETs)
- add "version=<n>" to .model line for models that have multiple
versions available (AFAIK only affects HiSIM_HV MOSFET models)
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/13775
Only update value and footprint fields from instance data if it's not
empty. These fields were not always stored in the instance data so
loading them from instance data that does not contain them will clear
the fields.
https://gitlab.com/kicad/code/kicad/-/issues/13735
Internal routines have no need for locking the mutex they already own.
While external routines that want to recalculate the Ratsnest do need an
exclusive lock before being allowed access
Fixes https://gitlab.com/kicad/code/kicad/issues/13011
Rather than update library symbols one at a time, queue them up by
schematic symbol to prevent multiple updates to the same symbol in
complex hierarchies. This also removes all of the library symbols
first which will clear out all of the library symbol variants that
were created by modifying library symbols in place and/or changes to
the symbol in the library.
Don't add new variant library symbol if an equivalent variant already
exists in the schematic local cache. This prevents duplicate library
symbols from being added to the local cache when the first variant in
the cache does not match that of the symbol being added.
Just testing a single point to find copper that is outside the board works
until the arc->segment conversion moves the board outline just enough to
have the filled copper slightly (few IU) outside of the converted outline.
Instead, we do an expensive check of comparing the size of the
intersection between the island and the island's intersection with the
board. If the intersection is at least half as large as the original
island, we can say with certainty that the island is inside. The margin
could be much smaller than half but this preserves the intent without
picking an arbitrary number that might be violated
Fixes https://gitlab.com/kicad/code/kicad/issues/13717