Also removes parallel implementation in favour of using the
normal one (with a new wxGauge-backed PROGRESS_REPORTER).
Fixes: lp:1764196
* https://bugs.launchpad.net/kicad/+bug/1764196
Symbol/footprint library and entry have the same set of forbidden
characters with a single exception, space character. To accommodate for
this difference, LIB_ID validation and fix methods have been extended to
specify the LIB_ID type that is checked (schematic/board).
LIB_ID::HasIllegalChars() and LIB_ID::FixIllegalChars() had two different
sets of characters treated as invalid in LIB_IDs. The set has been
factored out to another function to avoid duplication.
Field Editor dialog calls LIB_EDIT::SetFields() that deletes the old
LIB_FIELD objects and creates new ones. If any of the old LIB_FIELD
objects had been selected before invoking the dialog, then one of the
update UI event handlers will crash trying to access the object.
While we already cache the loaded footprint files, parsing said files
into the list is also time-intensive. Since the FOOTPRINT_LIST is
already hash-stamped against the current timestamps of the files that
make up the list, sharing a single copy of the list is quite
straight-forward.
The backup code was designed for a project with all of the schematics
in the project folder which is not always the case. Fix the schematic
backup to keep the schematic folder structure in tact during backups.
Fixes lp:1751662
https://bugs.launchpad.net/kicad/+bug/1751662
For some reason, when calling python and giving a full filename script, the last separator in the filename
must be '/', not '\'.
Otherwise the import command inside the script does not find files to import in the same folder as the script.
We cannot replace blindly '\' to '/' in command line because it does not work for file on a server (name starting by \\server_name\).
So the fix is just replacing one '\' in python script full filename.
This is not perfect, but at least it works for newly created plugin commands.
Currently, if a old label already containing a '/' (or a space) is edited, it is accepted,
but no new not allowed char can be added to the label.
(Previously, a sheet pin label was not filtered)
This also makes the dialog modeless so that one switch between
sheets while annotating to choose the base numbers for each
sheet (assuming they don't like the base number we pick because
of the order of the sheets).
Fixes: lp:1154131
* https://bugs.launchpad.net/kicad/+bug/1154131
Also fixes:
- forcing the annotation scope to "full schematic" when run
as a prerequisite to Generate Netlist.
- a long-standing bug where displaying extra items in a dialog
would mess up the height of the HTML_REPORT_PANEL (becasue
we were setting the html window's height rather than its
parent flexgrid.
- initializing the annotation radio buttons to safe values
(full schematic and keep existing)
Fixes: lp:1750062