- Ensure a change in plugin type is detected
- do not force automatic plugin type selection for *.lib files that need
an access to these libraries: they can be not always available.
For legacy libs ans cadstar libs the extension is .lib.
So we need to read the header of the file, and therefore expand the env var inside
the filename, if used.
1) Don't read libraries multiple times
2) VDMOS default is nchan if not specified
3) In the absence of a workbook default to LTSpice compatability
4) Don't attempt to write out a model line for a subckt; it never has
a baseModel
in GetMsgPanelInfo() (PPI, scale).
m_image name was confusing: it is not a wxImage, but a BITMAP_BASE item,
and m_image name was already in use in BITMAP_BASE, used inside SCH_IMAGE.
Bitmap properties dialog: show PPI value and add Title to dialog.
- Ensure that critical paths (ERC/netlister) are fully-rechecked
- Handle symbol/pin distinction in change markers
- Fully connect hierarchical pins in one pass descending
Previously, almost all connectivity updates were full updates, meaning
that the entire connectivity graph would be rebuilt each time a change
was made to the schematic. This update modifies the update to only
correct the subgraphs that are directly affected by the change.
It uses the existing connection graph to find all affected subgraphs as
well as connections to the changes based on the visible schematic.
These elements are removed from the existing connectivity graph and
marked dirty. They then have a new connectivity graph built only around
their changes. The resulting graph is merged into the original.
Currently, this ability is behind an advanced config flag
`IncrementalConnectivity` while testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10846
Fixes https://gitlab.com/kicad/code/kicad/issues/1794
Settings loading needs to account for potential chaining, so each
instance should be created before being Load()ed. Additionally, add the
settings loading to QA
Settings should be initialized on start-up. This removes the option of
lazily loading the settings from file and instead requires all settings
needed to be loaded on KiFACE start before requesting data from the
settings object
Adds maximum step size setting used by transient analysis solver,
and 'use initial conditions (uic)' setting. Enabling uic disables
DC operating point analysis and may introduce singularities. It requires
a careful selection of initial conditions of circuit elements.
Fixes https://gitlab.com/kicad/code/kicad/issues/2515