In-class initializers for "static const" class members must be constexpr,
however std::string is only "static const" itself and cannot be used
without compiler extensions.
With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded. This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.
Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.
Check the error message contents when no exception was caught to warn
the user of any accumulated errors.
Fixes lp:1690644
https://bugs.launchpad.net/kicad/+bug/1690644
Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
It turns out the fastest way to update wxDataViewCtrl is to nuke the
model and rebuild it from scratch rather than via
ItemAdded()/ItemDeleted() update notifications.
Fixes: lp:1734773
* https://bugs.launchpad.net/kicad/+bug/1734773
CHANGE: In Eeschema, when placing a component directly over an existing
wire, the wire is automatically removed where it shorted pins.
This helps workflow in Eeschema, allowing one to quickly add components
to existing lines.
Fixes: lp:1678449
* https://bugs.launchpad.net/kicad/+bug/1678449
This target seems to only create empty makefiles, tested on linux. And I
can not find any references to it in any of the current CMakeLists. Lets
remove it.
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
- Reverts behaviour of 3e71ed2421
- 3D model offset now explicitly written in mm, using "offset" tag
- Any read "at" tag is converted from inches to mm
- This will not break any 3D model offset when reading files
- It will however render files incompatible with old versions
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic