The connectivity routine would consider symbols, overwriting unused
subgraphs for pins that were not in the change list. This is resolved
by updating the full connectivity to only use pins in the graph since
symbols are not connected independently.
In the process of adding QA tests for this change, additional issues
with the schematic QA were discovered. Specifically, we were not
properly setting the root sheet UUID. This was partially masked by a
const_cast setting of the RefDes in sch_symbol when called the RefDes
getter. This exposed the fact that our QA ERC numbers did not match the
schematic editor stand alone ERC numbers. So the test value for one
check needed to be updated
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17528
Prior to this change, the schematic connectivity was updated any time a
change was made to a connectable object. Now the connectivity is only
updated when an object change actually affects the connectivity. Other
properties like line width, fill type, custom fonts, etc. will not cause
the connectivity graph to be rebuilt.
The SCH_COMMIT flag SKIP_CONNECTIVITY has been removed. All schematic
objects can test if they are connectable and if there have been changes
to any connection properties that require a connectivity rebuild.
Remove duplicate rebuild connectivity calls from editor control tool.
This was causing the tangling end test to get called four times on every
undo and redo action because the dangling end test is already called in
the connectivity graph calculation code.
Update connectivity when changing label names which fixes an unreported
connectivity bug.
Also fixes a wrap-around bug in SPICE_VALUE::Normalize() where
it would lose the run of itself if the value was already
normalized to either the largest or smallest UNIT_PREFIX.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17228
Avoid O(N^2) by spatial sorting, don't run checks if the bounding boxes
don't overlap.
A second copy is ordered by type to help classes that only want to check
a few types having to walk the whole list.
The paste code creates invalid KIID_PATH objects with a zero length. All
paths must include the root KIID at a minimum. Code was added to prune
the invalid paths and some defensive code was adding to the formatter to
prevent the crash in case there are other paths where someone generates
a zero length path.
Pruning orphaned instance data does not work when loading schematics prior
to version 7 because the paths did not include the root sheet UUID. Once
the file is saved to V7 or later, the next load will prune any orphaned or
invalid instance data for the current project.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16245