* Switch to using org.kicad.kicad as the main app ID
* Move the appstream file to a metainfo file
* Rename all metadata files to use the reverse DNS scheme
* Add header matching to mime type files where possible
* Add a mime type for gerber job files
* Add a QA test that verifies all the linux metadata files and
run it in CI
* Update the visible names in the launcher entries to be more
consistent with the internal visible names
* Update various strings and items in the metainfo file so they
are more descriptive and easier to read
It appears as though there was an optimization to skip testing segments if
one of their endpoints (and only the A point) was inside. Unclear the reason
for this, but I'm going to assume that it was intended to optimize the case
where both points are inside (like the point case above it).
After commit 9535153f9e there were no more IDs inside the legacy ID
system. Therefore the entire system for dispatching and looking up
the legacy ideas and handling those events can now be removed and
the tool dispatcher simplified (it no longer needs to know about
the ACTIONS class).
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols. This has a noticeable impact on symbol library
load performance. It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting. Hashing
may be a better solution here but this addressed the immediate problem.
A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations. More testing is required to
verify this.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
Adds Tom's internal P&S debugging tool. This is a work in progress and the code is quite messy for the moment, but I can't keep it in private branches forever and waste time rebasing it.
Note: experimental and *very unclean* code. Use at your own risk.
Now that footprint properties inherit custom fields from schematic
they are very useful.
Setting custom properties from python will also be handy in plugins
that need to somehow mark their own objects.
The nettie hack is used in DRC but we also need to use it in zone filler
to allow zones to be used with netties. We limit this to the
appropriate nets in the nettie
Fixes https://gitlab.com/kicad/code/kicad/issues/7351
This way the net names can be inspected in eeschema and cross-probing works.
Testcases updated for the name changes
CHANGED: all unconnected pins are now included in the netlist with no_connect_ prefixes
This behavior provided shorter net names, but was confusing if
the user gives an explicit strong driver in the subsheet but not
one in the parent sheet.
Testcases updated for net name changes; connectivity is the same
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4201
Depending on what order the subgraphs are processed in, it's
possible to hit a case where the parent sheet renames a bus
member before the bus neighbor renaming logic runs. In this
case, we don't want to apply the bus neighbor logic as it will
break connectivity to the parent sheet if that bus was not
also renamed (for example, if the hier ports only make net
connections and not bus connections)
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6887