1) Push a VAR onto the stack, not a resolved value
2) Don't collapse a PCB_LAYER_VALUE to a VALUE during processing
3) Make sure we run overloaded operators from the correct side
Fixes https://gitlab.com/kicad/code/kicad/issues/12437
(cherry picked from commit cf1565a16a)
wxWidgets 3.1 has deprecated wxPATH_NORM_ALL when normalizing file
paths when calling wxFileName::Normalize(). This change keeps the
existing behavior except in places where our own internal
ExpandEnvVarSubstitutions() to expand environment variables.
(cherry picked from commit 898ec0d094)
The wxtimer can fire multiple times and there exists the possiblity for
this to happen before the flags are properly set to prevent it. This
creates a concurrency mutex to skip the EDA_DRAW_PANEL_GAL refresh if
one is already underway.
Fixes https://gitlab.com/kicad/code/kicad/issues/12094
- Don't use GLX extension functions unless they are supported on the
connection. GLEW only checks for client library support.
- Don't try to set swap interval using glXSwapIntervalSGI when vsync is
not requested.
Fixes https://gitlab.com/kicad/code/kicad/issues/11751
(cherry picked from commit 0e2d3236b5)
Also find a few more places where we are reaching into a new frame to
perform actions that need to have dialogs closed.
Running actions should also wait for the next cycle rather than being
immediately executed when we are calling into a new frame. This allow
for the cleanup actions onClose() to happen prior to the next action
starting
Fixes https://gitlab.com/kicad/code/kicad/issues/11891
(cherry picked from commit 93fb00d815)
These can happen when a tool is active that sends signals when exiting
(e.g. deselectEvent). These may be caught by the active loop in another
tool which might try to update the UI after it has been freed. By
marking all tools as "shutdown", the only event returned to them should
be null. As an extra precaution, we flag the shutdown globally within
the tool manager and check this flag before launching either events or
new tools
Fixes https://gitlab.com/kicad/code/kicad/issues/10698
(cherry picked from commit db4f2d9dd8)
on gcc 12.1 / msys2 the large initialized list in bitmap_info.cpp breaks the
compiler (perhaps a bug in the compiler).
So, as workaround, the initialization sequence is modified.
Form master branch
It looks like this was overlooked by Jeff in 2020 not realizing eda_doc isn't built under eeschema but common in cc9ac37a0e
(cherry picked from commit f85251ef75)
Previously, coordinates were clamped to +- 60 inches. It makes no sense to
clamp them at plotter level: max cooed depends on the editor (schematic/board...)
Rename MAX_PAGE_SIZE_MILS to MAX_PAGE_SIZE_EESCHEMA_MILS and use it only for Eeschema.
Fixes#11196https://gitlab.com/kicad/code/kicad/issues/11196
(cherry picked from commit 21144481d2)
When moving windows between monitors on Mac that changes the DPI, we
observe incorrect re-sizing of columns and rows. This attempts to
rectify the situation by avoiding DPI changes for Mac builds.
Fixes https://gitlab.com/kicad/code/kicad/issues/10586
(cherry picked from commit 9722a05820)
When building the connectivity database, we should not be using the
connectivity to check for shapes.
To make this deterministic, we introduce two flags (ALWAYS_FLASH and
NEVER_FLASH) that are used with connectivity building to determine
whether a pad is flashed for connectivity or not. ZONE <-> PAD/VIA
connectivity will be checked with ALWAYS_FLASHED and all other
connectivity will be checked with NEVER_FLASHED if they are marked for
potential annular ring removal. If they are not marked for removal,
they will be checked ALWAYS_FLASHED.
Fixes https://gitlab.com/kicad/code/kicad/issues/11114
(cherry picked from commit 442aae19d9)
Arcs can be altered by the process of changing from on-disk
representation to in-memory representation. Saving back to disk without
modifying the arc should not modify the calculated values.
This stores a copy of the on-disk representation that is only used to
save back to disk in the event that the arc is not modified during
editing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10442
(cherry picked from commit cd7141fd10)
The fix for https://gitlab.com/kicad/code/kicad/issues/10529 kicked the
subsequent IDs for unit selection off the maximum ID value for popup
menus. This increases the maximum popup number (integers are free)
When setting previous values, we don't get the "OnFocus" event, so the
evaluation would not get triggered by simply repeating (using the
keyboard)
Fixes https://gitlab.com/kicad/code/kicad/issues/10752
We need the item to be currently selected when repeating the last symbol
insert. This ensures we have a valid selection before starting the move
tool and possibly getting odd system behavior from mouse positions
Fixes https://gitlab.com/kicad/code/kicad/issues/10619