Don't open-code knockout text shape generation in several different
places.
Make sure triangulated knockout text gets clearance added when
specified.
Collapse duplicated footprint text item plot routine (they're no
longer any different from plotting pcb text items).
(cherry picked from commit c71cf21e2f)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
Net tie groups are currently separated by comma. But comma is also an
allowed, albeit rare character for pad names. To allow pad names with
commas in net tie groups, the group definition must be escaped with a
forward slash for commas (and forward slashes).
Pad 1,2
Pad 2,3
Net-tie group "1\,2,2\,3"
Fixes https://gitlab.com/kicad/code/kicad/issues/13001
EDA_ITEMs are responsible for giving their parent a crack at it if
they failed to resolve it. This recurses all the way up to the schematic/
board, and then to the project.
Cross-reference handling is also move to the EDA_ITEMs. It must be done
before bubbling up so that we don't end up in loops. (The aDepth parameter
will break the loop, but without having done anything useful.)
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
Also adds some debugging to try to catch dangling pointers.
Also adds a cache for group bounding boxes (which will be expensive
to calculate for large groups).
Fixes https://gitlab.com/kicad/code/kicad/issues/12875
pad of a given number.
Also improves other DRC logic to tighten up the net-tie rules now that
we know which pads are allowed to short with which other pads.
Also removes the "Overlapping pads" DRC violation now that we know
whether or not overlapping pads in a net-tie footprint constitute a
short.
Fixes https://gitlab.com/kicad/code/kicad/issues/12506
Each pad group is allowed to short nets with other pads in its group.
Legacy footprints with the "net tie" keyword hack will get a single
group auto-created with all the footprint's pads in it.
DRC and the router now allow a track to collide with copper graphic items
while entering a net-tie pad as long as the closest point in the collision
is within the pad.
DRC (and the footprint checker) now check for copper items in the
footprint shorting pads which are not in the same pad group.
Fixes https://gitlab.com/kicad/code/kicad/issues/2265