Author SHA1 Message Date
Janne Huttunen a24c3f4a89 Implement Brymen BM25x series as a serial DMM.
The Brymen BM25x series supports the BC-20X that is an opto-isolated
serial cable. The link seems to be unidirectional i.e. when activated
the DMM periodically sends updates to the host while the host cannot
control the DMM in any way.

The protocol is documented in "6000-count-digital-multimeters-r1.pdf"
that is available from the manufacturer. Every 15 byte packet consists
of a bitmap where the bits correspond to segments or symbols on the
LCD display i.e. the DMM essentially sends the contents of its screen
to the host in every update. This driver then decodes the measured
quantity, unit and its value from the bitmap.
2014-08-01 20:31:26 +02:00
Bert Vermeulen 49224c2853 demo: Attach analog generator to channel, not channel group.
This also adds a new channel group "Analog", which has all analog
channels in it.
2014-07-29 02:00:57 +02:00
Bert Vermeulen dddabe3705 demo: Support changing the amplitude of analog channels. 2014-07-28 15:40:26 +02:00
Bert Vermeulen ed0b7fed10 demo: Free analog channel groups when done with them.
This fixes a memory leak.
2014-07-24 21:01:39 +02:00
Bert Vermeulen 4d7b36a0b5 fx2lafw: Check for valid samplerate before setting. 2014-07-23 12:32:35 +02:00
Bert Vermeulen b62bb97afb demo: Support continuous acquisition. 2014-07-23 04:53:25 +02:00
Bert Vermeulen 2f663c826a fx2lafw: Fix continuous mode. 2014-07-23 00:24:39 +02:00
Bert Vermeulen 155b680da4 Reorganize project tree. 2014-07-22 18:19:29 +02:00