Uwe Hermann 7dcaddd3f0 Have remaining drivers default to digits=2 for analog values.
The default so far was 0, which meant there would be no significant
digits at all, yielding results that looked strange/wrong to the user.

Long-term all remaining drivers should be fixed to use the actual,
correct digits and spec_digits values according to the device's
capabilities and/or datasheet/manual. Until that is done, a default
of digits=2 is used as a temporary workaround.

This fixes the remaining parts of bug #815.
2016-08-29 00:25:19 +02:00
Uwe Hermann 869c837511 Document if or why sometimes digits/spec_digits is 0. 2016-08-29 00:25:19 +02:00
Aurelien Jacobs a005472fa2 appa-55ii: properly set encoding digits also for log memory reception 2016-08-29 00:25:19 +02:00
Aurelien Jacobs 962172e495 analog: improve output readability by using SI prefix 2016-08-29 00:25:19 +02:00
Aurelien Jacobs 6c1c13cdcd gwinstek-gds-800: properly set encoding digits 2016-08-29 00:25:18 +02:00
Aurelien Jacobs 417412c8f8 hantek-dso: properly set encoding digits 2016-08-29 00:25:18 +02:00
Aurelien Jacobs 1e1fdbc994 hantek-6xxx: properly set encoding digits 2016-08-29 00:25:18 +02:00
Aurelien Jacobs 545101338a hung-chang-dso-2100: properly set encoding digits 2016-08-29 00:25:18 +02:00
Aurelien Jacobs ad4c0275c2 baylibre-acme: properly set encoding digits 2016-08-24 02:39:40 +02:00
Aurelien Jacobs d043b29d5c tondaj-sl-814: properly set encoding digits 2016-08-24 01:01:23 +02:00
Aurelien Jacobs 53b4ea3921 kecheng-kc-330b: properly set encoding digits 2016-08-24 01:01:23 +02:00
Aurelien Jacobs dcb6fcbb7b colead-slm: properly set encoding digits 2016-08-24 01:01:23 +02:00
Aurelien Jacobs 8c50007222 cem-dt-885x: properly set encoding digits 2016-08-24 01:01:23 +02:00
Aurelien Jacobs f4bd8a1718 gmc-mh-1x-2x: properly set encoding digits 2016-08-24 01:01:23 +02:00
Uwe Hermann 796f0e98a2 README.devices: Update firmware related information. 2016-08-23 12:58:20 +02:00
Aurelien Jacobs 96117c5660 document encoding.digits and spec.spec_digits 2016-08-23 12:58:06 +02:00
Aurelien Jacobs b66a0b5bdd mic-985xx: fix encoding digits 2016-08-23 12:58:06 +02:00
Aurelien Jacobs 1db537c3eb uni-t-ut32x: properly set encoding digits 2016-08-23 12:58:06 +02:00
Aurelien Jacobs fa2b19226d lascar-el-usb: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 0a2ffa3ebf center-3xx: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 0b8205504b kern-scale: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 3be044aa90 demo: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs bcaadb366f motech-lps-30x: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 1af428d018 manson-hcs-3xxx: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 841c15a5fa korad-kaxxxxp: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs fad810b502 atten-pps3xxx: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 24b6882ffa deree-de5000: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs b8f07f4221 rigol-ds: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 6ed709fecd scpi-pps: properly set encoding digits 2016-08-23 12:58:05 +02:00
Aurelien Jacobs 4301f1726a maynuo-m97: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs a66d44bee1 vc870: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs 4f414d4cbe ut71x: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs 47166326ef ut372: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs 96a06b4203 rs9lcd: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs e677490e58 metex14: properly set encoding digits
This closes bug #815.
2016-08-23 12:58:04 +02:00
Aurelien Jacobs 8882e7e6cf m2110: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs aad6d8d206 fs9922: properly set encoding digits 2016-08-23 12:58:04 +02:00
Aurelien Jacobs 70e28e7802 fs9721: properly set encoding digits 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 8cbf5627ba es519xx: properly set encoding digits 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 427015d7c1 dtm0660: properly set encoding digits 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 25198a7e89 brymen-bm25x: properly set encoding digits 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 1baf30f5f7 brymen-bm86x: properly set encoding digits 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 5fe1b5cc14 brymen-bm86x: remove redundant initilialization 2016-08-23 12:36:19 +02:00
Aurelien Jacobs 7b78449e40 appa-55ii: properly set encoding digits 2016-08-23 12:36:19 +02:00
Erik Montnemery 817b7441a1 hantek-6xxx: Ignore requests to set Hantek 6022BE coupling.
Here's a patch to "Ignore requests to set coupling for the Hantek 6022BE",
this clears the LIBUSB errors for me.

Also in the patch:

 - There is a crash because config_list() can be called with sdi == NULL.

   This can be reproduced by doing:
     "sigrok-cli.exe --driver hantek-6xxx --show"

 - There seems to be a very unsafe loop in config_set() when setting COUPLING;
   the coupling vector is assumed to be zero terminated, but is not declared
   as such.

   Note: The same issue is present also for other hardware, at least for
   hantek-dso/api.c. The patch is only for hantek-6xxx though.
2016-08-21 18:54:15 +02:00
Sebastian Zagrodzki 7f46b27ef2 hantek-6xxx: sdi might be NULL - don't assign devc until !sdi is checked. 2016-08-21 18:54:09 +02:00
Mike Meyer 0d8a3063e3 hantek-6xxx: Fix the device scan to not scan the NULL entry. 2016-08-21 18:53:55 +02:00
Aurelien Jacobs bf85ea2110 drivers: don't try to access the sr_driver_list section with no driver compiled.
This closes bug #820.
2016-08-15 01:45:50 +02:00
Benjamin Larsson 5eb4ba29d0 hantek-6xxx: only show DC coupling for the Hantek device 2016-08-15 01:16:54 +02:00
Uwe Hermann af7f88242e hantek-6xxx: Fix some issues by using power-of-two data sizes.
There were issues when using non-power-of-two data sizes with e.g.
the Hantek 6022BE device. For example, on Windows the acquisition would
simply hang and never complete:

  hantek-6xxx: receive_transfer(): status LIBUSB_TRANSFER_ERROR received 0 bytes

The issue was reported by Erik Montnemery on the mailing list, the
original patch was posted by "mmark" here (thanks!):

  http://www.eevblog.com/forum/testgear/sainsmart-dds120-usb-oscilloscope-(buudai-bm102)/msg911729/#msg911729

The issue has been verified by me on Windows and Linux, and also that
this change does indeed fix it (tested Hantek 6022BE and Sainsmart DDS120).

Neither PulseView nor sigrok-cli hang anymore on Windows, and on Linux
the log messages suggest improvements as well:

  -hantek-6xxx: data_amount 712
  +hantek-6xxx: data_amount: 200 (rounded to power of 2: 512)

  -hantek-6xxx: receive_transfer(): calculated samplerate == 2327ks/s
  -hantek-6xxx: receive_transfer(): status LIBUSB_TRANSFER_OVERFLOW received 512 bytes.
  +hantek-6xxx: receive_transfer(): calculated samplerate == 1969ks/s
  +hantek-6xxx: receive_transfer(): status LIBUSB_SUCCESS / LIBUSB_TRANSFER_COMPLETED received 512 bytes.

This fixes bug #821.
2016-08-15 00:58:10 +02:00