- fix the resolution of the CONF?-response:
the resolution is given with 6 decimal places
(instead of 8) like this:
VOLT +5.000000E+00,+1.000000E-04
- add more measurement modes that are possible with the meter:
CONT,COND,TEMP,PULS
Few DMM drivers already did it. This commit adjusts the remaining DMM
drivers, to set the "DC" flag for measurements in diode mode.
This fixes bug #144.
Although I don't have the hardware to test, the nature of the change and
the arrangement of driver code suggests it's good. When a meter already
communicated the "DC" status, the change does nothing and won't harm.
The change ensures "DC" is flagged for those meters which previously
didn't, which is desirable.
This allows much faster and configurable sampling rate, and faster
reaction to function switch.
This also gives a more repeatable job ordering and more reliable
query/reply association.