Peter Stuge
b8072700c1
Add a struct sr_context * parameter to sr_init() and sr_exit()
2012-10-21 20:23:14 +02:00
Uwe Hermann
026c822d8c
Move 'struct drv_context' to sigrok-internal.h.
...
It's not meant to be visible to frontends.
2012-10-21 16:40:13 +02:00
Alexandru Gagniuc
7c41dc4774
radioshack-dmm: Implement support for "LOGIC" mode
...
LOGIC mode sends the following data:
V < 0 : actual voltage
0 <= V < 1 : LOW
1 <= V < 2 : actual voltage
2 <= V : HIGH
We follow the same idea, and set our unit to BOOLEAN for the crazy
case (HIGH or LOW).
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-20 23:03:51 +02:00
Alexandru Gagniuc
dfd8f56ef4
libsigrok: (Trivial) fix packet type in datafeed_dump
...
datafeed_dump would print SR_DF_META_LOGIC when a SR_DF_META_ANALOG
was recieved. Fix that.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-20 23:03:51 +02:00
Alexandru Gagniuc
0f70830194
libsigrok: (Trivial) Add support for 2400 baud
...
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-20 23:02:14 +02:00
Bert Vermeulen
777bbd5b98
add SR_HWOPT_* documentation
2012-10-18 22:59:32 +02:00
Bert Vermeulen
fe31f8b9f9
fluke-dmm: add support for Fluke 187
2012-10-16 23:33:54 +02:00
Bert Vermeulen
796a79eb75
analog: add pretty-printer for dBu and dBV
2012-10-16 23:33:54 +02:00
Bert Vermeulen
6b86923463
add SR_UNIT_DECIBEL_VOLT (dBu)
2012-10-16 23:33:54 +02:00
Bert Vermeulen
d713e56181
analog: sane printing of very small and negative values
2012-10-16 23:33:54 +02:00
Uwe Hermann
8ed262509f
HACKING: Cosmetics.
2012-10-16 14:48:39 +02:00
Uwe Hermann
6aff0d16df
Build fix for Windows/MinGW.
...
On Window/MinGW 'recv' seems to be already defined in some headers.
Use 'receive' instead, for now.
2012-10-16 12:19:36 +02:00
Uwe Hermann
a2353f6051
Re-add HACKING file after repo split.
2012-10-16 12:19:36 +02:00
Alexandru Gagniuc
be8dbf3ab2
radioshack-dmm: (Trivial) Convenience fixes
...
While testing the new radioshack-dmm driver with pulseview, I found
a few inconvenients.
1. Print an info message when a port is probed, and when a device is
found. This makes it easy to tell if and where the driver is looking.
2. num_samples was not reset after the first aquisition, so the
second aquisition would quit right away. Reset num_samples at start
of a new aquisition.
3. There's no need to open the serial port RW, so change O_RDWR to
O_RDONLY when opening the port.
These changes are too trivial to split into different patches.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-16 11:16:41 +02:00
Bert Vermeulen
7b0a85c81c
radioshack-dmm: build fixes
2012-10-15 18:25:48 +02:00
Alexandru Gagniuc
d375b3c3ec
radioshack-dmm: Add support for Radioshack 22-812 DMM
...
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:32:58 +02:00
Alexandru Gagniuc
b82a17d370
libsigrok.h: Add measured quantity and units used by Radioshack 22-812
...
The Radioshack 22-812 can measure parameters such as transistor gain,
dbm, etc. Add those to libsigrok.h.
The SR_UNIT_UNITLESS is for quantities that do not have units. Any
ratio or gain are just factors, whic do not have units. Specifically,
a transistor's gain, or hFE, is a unitless quantity.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:32:58 +02:00
Alexandru Gagniuc
e8e9dcdd70
serial: (Trivial) add support for 4800 baud
...
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:32:58 +02:00
Alexandru Gagniuc
5fef6b9d6c
.qitignore: Ignore KDE backup files
...
*.kate-swp files can become annoying, so ignore them.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-10-15 17:31:19 +02:00
Bert Vermeulen
2b98e0aaab
analog: support AC+DC unit modifier
2012-10-15 11:32:36 +02:00
Bert Vermeulen
17ff11240e
don't accept numbers as probe identifiers in trigger string
...
Only the probe name, as supplied by the device driver, is accepted.
2012-10-14 14:59:07 +02:00
Uwe Hermann
33df15f144
Quick workaround for g_match_info_unref().
2012-10-11 23:57:26 +02:00
Uwe Hermann
4a1c927fd6
README: Add status, update URL, small fixes.
2012-10-10 23:36:32 +02:00
Bert Vermeulen
a5b2293fa8
updated URLs and description
2012-10-08 18:52:36 +02:00
Bert Vermeulen
c750b9b194
restore pre-split ignores
2012-10-08 15:53:00 +02:00
Uwe Hermann
a2e222d24f
sr: struct drv_context is global now.
2012-09-27 23:29:33 +02:00
Bert Vermeulen
d38d2ef0ce
fluke-dmm: support for all basic 287 functionality
2012-09-25 19:53:05 +02:00
Bert Vermeulen
96b3b3d568
sr: add support for conductance measurements in Siemens
2012-09-25 19:53:05 +02:00
Bert Vermeulen
aa839a5c4f
sr: add support for pulse width measurements
2012-09-25 19:53:05 +02:00
Bert Vermeulen
f46a36ad80
fluke-dmm: definitely use CR as line terminator
2012-09-25 19:53:05 +02:00
Bert Vermeulen
acd29accb3
fluke-dmm: add Fluke 287 to supported list
2012-09-25 19:53:05 +02:00
Bert Vermeulen
fb9d3bf9cc
sr: always turn off ICRNL on serial ports
...
It does rather screw with protocols that use CR.
2012-09-25 19:53:05 +02:00
Bert Vermeulen
d3f8f1415c
fluke-dmm: flesh out the driver API
2012-09-25 19:53:05 +02:00
Bert Vermeulen
4129832014
fluke-dmm: auto-discover serial bitrate if not provided
2012-09-25 19:53:05 +02:00
Bert Vermeulen
bc41e012e6
fluke-dmm: don't log anything if no conn params given
2012-09-25 19:53:05 +02:00
Bert Vermeulen
fb480d578e
fluke-dmm: fix discovery
2012-09-25 19:53:05 +02:00
Bert Vermeulen
5c51e09868
sr: turn off canonical mode and echo ion serial ports by default
2012-09-25 19:53:05 +02:00
Bert Vermeulen
e7edd64f45
fluke-dmm: build fixes
2012-09-25 19:53:05 +02:00
Bert Vermeulen
4f958423d1
fluke-dmm: basic scan functionality
2012-09-25 19:53:05 +02:00
Bert Vermeulen
883a2e9e71
fluke-dmm: initial driver skeleton
2012-09-25 19:53:05 +02:00
Bert Vermeulen
c2016fa0eb
agilent-dmm: don't log anything if no conn params given
2012-09-17 00:00:27 +02:00
Bert Vermeulen
e9022f596d
sr: make struct drv_context global
2012-09-11 21:27:26 +02:00
Bert Vermeulen
f5cfe894ec
fx2lafw: use default libusb context
2012-09-11 21:20:50 +02:00
Bert Vermeulen
19b0cce312
hantek-dso: use default libusb context
2012-09-11 21:16:16 +02:00
Bert Vermeulen
7c1cb432b8
sr: enable genericdmm and agilent-dmm drivers by default
2012-09-10 22:14:37 +02:00
Bert Vermeulen
b186aa78b8
agilent-dmm: fix model identifiers
2012-09-10 21:27:50 +02:00
Bert Vermeulen
8c0152f29b
agilent-dmm: tentative support for all U123x and U125x models
...
Only tested on U1233A, but it just might work.
The U125x protocol decoding only supports voltage, current, resistance,
capacitance and diode measurements for now.
2012-09-10 01:00:48 +02:00
Bert Vermeulen
a4394fb3d9
agilent-dmm: code cleanup
...
This should make it easier to support other Agilent U12xx models
2012-09-10 00:13:26 +02:00
Bert Vermeulen
e066c32a25
agilent-dmm: fix AC/DC mode detection
2012-09-09 22:49:07 +02:00
Bert Vermeulen
f2e86bbfa6
agilent-dmm: make parser deal with input better
2012-09-09 22:48:22 +02:00