Mathias Katzer a1b61e6e04 hameg-hmo: Set SR_CONF_GET | SR_CONF_SET for frame limit.
Reading analog data from an HMO1024 (Firmware 04.527) failed because the
frame limit could not be set.
2015-01-11 01:43:12 +01:00
Bert Vermeulen 974fb0fffa saleae-logic16: Show libusb transfer status name instead of code. 2014-11-28 00:21:56 +01:00
Uwe Hermann a11e10ec91 saleae-logic16: Change two errors into warnings.
Related to #466, convert two more sanity checks from errors into warnings.
This may allow more devices to work with libsigrok.
2014-11-27 23:22:05 +01:00
Bert Vermeulen 5cfcab6603 saleae-logic16: Clearer error message. 2014-11-27 01:01:13 +01:00
Aurelien Jacobs e743a47d6d beaglelogic: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 22:13:36 +01:00
Aurelien Jacobs 5a971f66a3 saleae-logic16: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 22:13:36 +01:00
Aurelien Jacobs 7bfcb25cf1 fx2lafw: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 16:56:34 +01:00
Aurelien Jacobs fe5a735553 soft-trigger: Add support for pre-triggering. 2014-11-25 16:56:34 +01:00
Uwe Hermann b6085eb179 manson-hcs-3xxx: Fix incorrect SR_CONF_SCAN_OPTIONS handling.
The SR_CONF_SCAN_OPTIONS key must be listable with or without sdi,
otherwise the device will not be detected by frontends.
2014-11-23 21:13:16 +01:00
Tim Hatch cd3c4df35a saleae-logic16: Downgrade error during capture to a message.
Some clone doesn't set this to the exact same value, and both bits in 0x48 are
marked as unknown at
http://sigrok.org/wiki/Saleae_Logic16/Firmware#FPGA_variables

This fixes bug #466.
2014-11-23 13:47:45 +01:00
Uwe Hermann 91219afc75 Use g_malloc0() consistently, simplify error handling.
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.

Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
2014-11-22 17:02:57 +01:00
Uwe Hermann c368e6f3d2 Don't check sr_channel_new() return value (always succeeds).
We now use g_malloc0() for the allocation and assume the allocation
will always succeed, thus sr_channel_new() will always return a
valid new channel.
2014-11-21 12:10:05 +01:00
Uwe Hermann f57d8ffe66 Consistently use g_malloc0() for allocating devc.
We assume the allocation will always succeed, hence no need for
checking the returned value.
2014-11-21 12:09:01 +01:00
Uwe Hermann aac29cc192 Eliminate sr_dev_inst_new(). 2014-11-21 02:01:36 +01:00
Aurelien Jacobs cf0280fa1b yokogawa-dlm: Publish driver options. 2014-11-19 23:54:01 +01:00
Aurelien Jacobs 413f1944d1 motech-lps-30x: Publish driver options. 2014-11-19 23:53:35 +01:00
Aurelien Jacobs f3ba3c119c manson-hcs-3xxx: Publish driver options. 2014-11-19 23:53:10 +01:00
Aurelien Jacobs 6ec3ef9b92 hameg-hmo: Publish driver options. 2014-11-19 23:52:51 +01:00
Uwe Hermann e07edc83d6 mic-985xx: Correctly report SR_CONF_THERMOMETER/_HYGROMETER.
Some models only log temperature, others log temperature and humidity
(so they need different drvopts).
2014-11-18 23:43:38 +01:00
Uwe Hermann 20a7cd07c9 mic-985xx: Drop unneeded #define. 2014-11-18 23:26:10 +01:00
Uwe Hermann d6e1e6c4e1 mic-985xx: Publish driver options. 2014-11-18 23:26:10 +01:00
Uwe Hermann 489c338884 center-3xx: Drop unneeded #define. 2014-11-18 23:20:09 +01:00
Uwe Hermann 6685e9a6b3 center-3xx: Publish driver options. 2014-11-18 23:20:09 +01:00
Bert Vermeulen 5c868fef43 Revert "victor-dmm: Set spec digits to 3, matching the display."
This reverts commit 28b4243493.
2014-11-18 18:10:19 +01:00
Bert Vermeulen 63ea6141b6 ols: Publish driver options. 2014-11-18 17:41:36 +01:00
Bert Vermeulen f9dada0b60 agilent-dmm: Now really fix driver options. 2014-11-18 17:31:58 +01:00
Bert Vermeulen 42a47a9a4b appa-55ii: Publish driver options. 2014-11-18 16:50:47 +01:00
Bert Vermeulen 5ecd9049e5 hantek-dso: Fix driver options. 2014-11-18 16:46:39 +01:00
Bert Vermeulen 1f889afd61 atten-pps3xxx: Fix driver options. 2014-11-18 16:44:58 +01:00
Bert Vermeulen 023c73ae05 cem-dt-885x: Fix driver options. 2014-11-18 16:44:14 +01:00
Bert Vermeulen 9d9cf1c4b9 scpi-pps: Fix driver options. 2014-11-18 16:44:14 +01:00
Bert Vermeulen 2ff11e50a5 asix-sigma: Fix driver options. 2014-11-18 16:30:47 +01:00
Bert Vermeulen 1e4a7cace2 demo: Fix driver options. 2014-11-18 15:39:46 +01:00
Bert Vermeulen ff6b76a145 fx2lafw: Publish driver options. 2014-11-18 15:35:30 +01:00
Bert Vermeulen ce4bd05256 agilent-dmm: Publish driver options. 2014-11-18 15:34:52 +01:00
Bert Vermeulen 5533392828 victor-dmm: Publish driver options. 2014-11-18 14:34:02 +01:00
Bert Vermeulen 28b4243493 victor-dmm: Set spec digits to 3, matching the display. 2014-11-18 00:24:08 +01:00
Aurelien Jacobs 41caa31909 Add a sr_analog_init() API to initialize sr_datafeed_analog2 struct.
It fills the fields with reasonable default values that should suit
most of the drivers. Drivers are obviously free to override the fields
they want after initializing.
2014-11-17 22:04:24 +01:00
Aurelien Jacobs 62f155f0c7 demo: Fix analog output at low samplerate. 2014-11-17 13:39:53 +01:00
Aurelien Jacobs 3772c04990 demo: Fix square pattern output shorter than other patterns. 2014-11-17 13:39:53 +01:00
Bert Vermeulen 4b664cd6ce demo: Use allocation for model string. 2014-11-14 11:37:11 +01:00
Uwe Hermann 676877f6ce mic-985xx: Convert to use SR_DF_ANALOG2. 2014-11-13 22:51:39 +01:00
Uwe Hermann a84a26d98a victor-dmm: Convert to use SR_DF_ANALOG2. 2014-11-13 22:51:39 +01:00
Uwe Hermann 0af636bed9 Change sr_dev_inst_new() to take no parameters.
Change all callers to set the fields manually as needed.
2014-11-12 17:18:46 +01:00
Uwe Hermann 6508992d04 Brymen BM25x: Drop unneeded _ser/_SER suffix.
There's only one cable for this DMM, thus there's no need for a
_ser/_SER suffix or for specifying the cable name.
2014-11-02 16:40:40 +01:00
Uffe Jakobsen bce75f947d ols: Fix a serial port related issue on FreeBSD.
Add sp_drain() to ensure bytes have actually been transmitted
over the wire.

This fixes bug #414.
2014-11-01 19:44:36 +01:00
Uwe Hermann aab4b8cb70 fx2lafw: Fix wide (16bit) sampling case.
This fixes bug #373.
2014-10-29 22:46:57 +01:00
Bert Vermeulen e3594306a9 zeroplus-logic-cube: Add support for AKIP-9101.
Thanks to Nikita Nazarenko for the patch.
2014-10-29 13:26:57 +01:00
Bert Vermeulen 933defaa03 hantek-dso: Fix driver/global/channel group config keys.
This was way behind and did not yet support channel groups.
2014-10-27 17:09:57 +01:00
Bert Vermeulen e7ba5a994b asix-sigma: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen a258204e00 scpi-pps: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen 390795c099 demo: Rearrange driver and device options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen d7125bfa1e cem-dt-885x: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen d6fa8ace94 atten-pps3xxx: Publish driver options. 2014-10-27 17:09:47 +01:00
Uwe Hermann 8769478c07 Add support for the UNI-T UT71x series (aka Voltcraft VC-920/940/960).
Tested on the Voltcraft VC-920 and VC-940 (both UT-D02 and UT-D04
cables), but it should work for all devices in this series without
any changes.
2014-10-25 17:14:30 +02:00
Bert Vermeulen cf49d66bc6 hantek-dso: Properly zero out MQ flags. 2014-10-22 22:19:41 +02:00
Bert Vermeulen c3eadb0760 scpi-pps: Add support for Fluke/Philips PM2800 series. 2014-10-18 23:21:37 +02:00
Bert Vermeulen c1d56d2013 scpi-pps: Move non-standard data type processing to SCPI parser. 2014-10-18 23:21:37 +02:00
Bert Vermeulen 4a471029c2 scpi-pps: Add channel probe facility to scan.
If the number and specs of the device's channels are not static, i.e.
need to be probed, this facility is needed.

Initially this will be used for the Philips PM2800 series, where only
the model returned by *IDN? is needed. However this could also be used
to do actual discovery with vendor-specific SCPI commands.
2014-10-18 23:21:37 +02:00
Soeren Apel d1314831e4 yokogawa-dlm: Populate sdi->serial_num and sdi->version 2014-10-17 03:02:52 +02:00
Soeren Apel b3fccc851b rigol-ds: Populate sdi->serial_num 2014-10-17 03:02:52 +02:00
Soeren Apel b33db61c48 hameg-hmo: Populate sdi->serial_num 2014-10-17 03:02:52 +02:00
Soeren Apel d08667c53b scpi-pps: Populate sdi->serial_num and fix hw_info mem leak 2014-10-17 03:02:52 +02:00
Soeren Apel 0699ccdd92 sysclk-lwla: Let the sdi getter populate sdi->connection_id
This fixes bug #441.
2014-10-17 03:02:52 +02:00
Soeren Apel c962d07cba ikalogic-scanalogic2: Let the sdi getter popuplage sdi->connection_id
This fixes bug #440.
2014-10-17 03:02:52 +02:00
Bert Vermeulen 984e4b0db8 scpi-pps: Start acquisition on the first enabled channel. 2014-10-17 03:00:55 +02:00
Bert Vermeulen 624503ae90 scpi-pps: Optimize channel selection.
This avoids sending a channel selection command to the device if
the channel we're working on is already on the same underlying
output channel.
2014-10-17 03:00:05 +02:00
Bert Vermeulen ee2860ee11 scpi-pps: Disable beeper during session.
At least the Rigol DP800 series trigger the beeper when changing
channels remotely. Which gets rather annoying when doing acquisition
on three channels as fast as you can.
2014-10-16 15:24:27 +02:00
Bert Vermeulen bf48ccebee scpi-pps: Properly clean up acquisition session. 2014-10-16 14:55:56 +02:00
Bert Vermeulen 60475cd788 scpi-pps: Use only standard SCPI for Rigol DP800 series. 2014-10-16 13:23:21 +02:00
Bert Vermeulen ca95e90fb3 Use SR_CONF_OUTPUT_VOLTAGE_TARGET and _CURRENT_LIMIT.
These describe them better; the two are fundamentally different
things to set.
2014-10-15 12:03:00 +02:00
Bert Vermeulen 53a81803e4 scpi-pps: Split boolean set options into enable/disable.
This makes it easier to support devices that need something else
than "ON" or "OFF".
2014-10-13 12:50:28 +02:00
Janne Huttunen b50891952d Add driver for DER EE DE-5000 LCR meter.
Add a driver for the DER EE DE-5000 LCR meter. This meter is based on
the Cyrustek ES51919/ES51920 chipset and communicates with the host
computer via an optional connectivity kit.

The kit uses an optoisolated unidirectional link to connect to the
meter and an USB cable on the host side. Internally the connection is
using the FTDI FT232R USB UART chip i.e. from the host computer point
of view the meter is connected into an RS-232 serial port.

This driver implements just a thin shim layer for registering the
driver and uses the es51919 module for all the actual work.
2014-10-13 00:56:11 +02:00
Bert Vermeulen f4d3a4fb9a ols: Fix serial port timeout. 2014-10-08 03:00:47 +02:00
Bert Vermeulen 9e6d9bee2a colead-slm: Fix serial port timeout. 2014-10-08 02:23:20 +02:00
Bert Vermeulen 2eb1612d46 atten-pps3xxx: Use serial_timeout(). 2014-10-06 12:12:13 +02:00
Bert Vermeulen 945cfd4fdd atten-pps3xxx: Fix serial port timeout. 2014-10-05 12:29:28 +02:00
Bert Vermeulen 204014007f fluke-dmm: Fix blocking serial write timeout. 2014-10-04 10:39:11 +02:00
Bert Vermeulen 95779b43b8 agilent-dmm: Fix blocking serial write timeout. 2014-10-04 10:39:11 +02:00
Martin Ling eead278242 Add a timeout parameter to blocking serial calls.
Set this new parameter to 0 (no timeout) at every call site. This is
consistent with previous behaviour, so cannot cause any regressions.

Waiting forever for a serial operation is clearly always wrong. Without
specific knowledge of each device and driver however, I can't choose
appropriate timeouts for each call. The maintainers of these drivers
will need to do so, and also add appropriate handling of timeouts.

When this commit is merged, a bug should be entered for each driver
that is touched by it.
2014-10-02 22:06:16 +02:00
Bert Vermeulen 7ce59a3133 Avoid serial_write_blocking() warnings. 2014-10-02 16:01:27 +02:00
Martin Ling 081c214eac Fix similar broken error handling on several serial calls. 2014-10-02 15:57:02 +02:00
Bert Vermeulen 7f22cd9554 kecheng-kc-330b: Fix missing time/frequency weighting. 2014-10-02 15:06:36 +02:00
Bert Vermeulen 8219214ff0 hantek-dso: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:03:18 +02:00
Bert Vermeulen 385cb66058 demo: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:02:14 +02:00
Bert Vermeulen f4d0020ec6 fluke-dmm: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:00:37 +02:00
Bert Vermeulen 65c8d48f14 chronovu-la8: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:58:57 +02:00
Bert Vermeulen 382cb19f29 asix-sigma: Trigger code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:53:20 +02:00
Bert Vermeulen 90486ba835 agilent-dmm: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:11:35 +02:00
Soeren Apel 66c91e2509 Removal of sdi->index, step 8: fix victor-dmm 2014-09-30 01:42:58 +02:00
Soeren Apel bde9fbd197 Removal of sdi->index, step 7: fix testo 2014-09-30 01:42:58 +02:00
Soeren Apel c79d4444fe Removal of sdi->index, step 6: fix sysclk-lwla 2014-09-30 01:42:58 +02:00
Soeren Apel 65340dd5df Removal of sdi->index, step 5: fix ikalogic-scanalogic2 2014-09-30 01:42:58 +02:00
Soeren Apel aed4ad0bea Removal of sdi->index, step 4: fix trivial sr_dev_inst_new() calls 2014-09-30 01:42:58 +02:00
Soeren Apel ce7d3578e3 saleae-logic16: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel 71580ef1f3 Remove sdi->index from openbench-logic-sniffer and pipistrello-ols 2014-09-30 01:42:58 +02:00
Soeren Apel 395206f460 hantek-dso: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel ee4f9bb1bd zeroplus-logic-cube: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel 5e2c86eb31 fx2lafw: Use physical USB connection instead of sdi->index
Previously, sdi->index was used to tell several identical fx2lafw-compatible
devices apart. This was a bit of a hack, so this patch makes it use physical
device connections instead. They're guaranteed to remain the same even if
the USB device reconnects.
2014-09-27 12:49:44 +02:00
Martin Ling 7ef93fb09f tondaj-sl-814: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:32 +02:00
Martin Ling 539a85596f tondaj-sl-814: Mark serial read/write calls as blocking.
These calls are executed from an event handler and were previously nonblocking,
but they have no partial read/write handling. The code is already marked TODO
for improvement.
2014-09-24 23:30:32 +02:00
Martin Ling 47d98603e7 tondaj-sl-814: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:31 +02:00
Martin Ling 9333691aaf teleinfo: Mark serial read as nonblocking, remove SERIAL_NONBLOCK flag.
This call was already nonblocking due to the flag.
2014-09-24 23:30:31 +02:00
Martin Ling 4ded59eef0 openbench-logic-sniffer: Remove SERIAL_NONBLOCK flag.
All calls in this driver are already explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling d12ef776d3 norma-dmm: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 92714255b3 norma-dmm: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling 8849f45ad7 norma-dmm: Make write call block.
This call was previously nonblocking, but has no partial write handling.
It is called in the scan where it is free to block.
2014-09-24 23:30:31 +02:00
Martin Ling 32950cc071 norma-dmm: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:31 +02:00
Martin Ling 5b980134c5 motech-lps-30x: Remove SERIAL_NONBLOCK.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 856dccb7a6 motech-lps-30x: Make serial write call block.
This call was previously explicitly nonblocking, but has no partial write
handling. It sends a short packet so should be OK to block, most likely the
output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling e050124095 motech-lps-30x: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:31 +02:00
Martin Ling 51056d61ec mic-985xx: Remove SERIAL_NONBLOCK call.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 3e2373247c mic-985xx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling 98842e53eb mic-985xx: Mark serial read as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:31 +02:00
Martin Ling e13e354f89 gmc-mh-1x-2x: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 612db3c44b gmc-mh-1x-2x: Make serial write calls block.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.

Fix error handling for some: serial_write can return any negative error code.
2014-09-24 23:30:30 +02:00
Martin Ling e1960467ce gmc-mh-1x-2x: Make serial write call block, and fix error handling.
This call was previously nonblocking, but there is no handling of partial
writes. It is called from config_set where it is free to block.

Also fix error handling: serial_write can return any negative error code,
not just -1.
2014-09-24 23:30:30 +02:00
Martin Ling 4a0eda2b70 gmc-mh-1x-2x: Mark serial read calls as nonblocking.
These calls were already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. They only read one byte. A return value of zero is not
handled, but should not occur in theory due to the G_IO_IN check. It might be
good to add handling of a zero return anyway, since I'm not sure if this is
always accurate.
2014-09-24 23:30:30 +02:00
Martin Ling 0714a010cc gmc-mh-1x-2x: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:30 +02:00
Martin Ling bb27c76513 fluke-dmm: Make serial write calls block, and fix error handling.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.

Also fix error handling for these calls, which seems to have been retained from
previous direct usage of write() to a serial port fd.
2014-09-24 23:30:30 +02:00
Martin Ling 50276118ca fluke-dmm: Make serial write calls block, and fix error handling.
These calls were previously nonblocking, but have no partial write handling.
They are made from scan and acquisition_start contexts where they are free
to block.

Remove the SERIAL_NONBLOCK at open, which only applied during scan, since all
calls in the scan are now explicitly blocking.

Also fix error handling for these calls, which appears to have been kept
from a previous direct usage of write() on a serial port fd.
2014-09-24 23:30:30 +02:00
Martin Ling 707fa85ad5 fluke-dmm: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Only one byte is read. The case of 0 being returned
is not handled, but the call is only made if G_IO_IN occurred so in theory,
there should be a byte available. It might be wise to add handling for a
return of 0 nonetheless, as I'm not sure if this is always accurate.
2014-09-24 23:30:23 +02:00
Martin Ling 55e32714f9 conrad-digi-35-cpu: Make serial write call block.
This call was previously nonblocking, but there is no partial write handling.
It is only called from config_set so it is free to block.
2014-09-24 23:30:01 +02:00
Martin Ling 0ac161bba0 conrad-digi-35-cpu: Remove SERIAL_NONBLOCK flag from open at scan time.
This open call is only made to check access, the port is closed immediately
afterwards. The flag therefore has no effect.
2014-09-24 23:30:01 +02:00
Martin Ling c9fc06d7f0 colead-slm: Mark serial read calls as nonblocking.
This is an odd one. These calls are made from a receive handler so should not
block, and appear to be setup correctly to handle partial reads or no data
available. However, the driver was not opening the port with SERIAL_NONBLOCK
so these calls would have been blocking. Make them nonblocking.
2014-09-24 23:30:01 +02:00
Martin Ling 258a23134d center-3xx: Remove SERIAL_NONBLOCK flag.
All serial calls in this driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling c1da74fc0a center-3xx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling 3582ce8a01 center-3xx: Mark serial read call as nonblocking.
This call was already nonblocking because the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:00 +02:00
Martin Ling d7b269da8f cem-dt-885x: Mark serial access as nonblocking, remove SERIAL_NONBLOCK flag.
These calls were already nonblocking since this driver opened the port with
the SERIAL_NONBLOCK flag. Having marked them as such, we can remove the flag.

Also remove an unnecessary reopen of the port to change its blocking status.
2014-09-24 23:30:00 +02:00
Martin Ling ca4266a02f brymen-dmm: Remove SERIAL_NONBLOCK flag.
All serial read/write calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling 776313d997 brymen-dmm: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling 44be13b1f8 brymen-dmm: Mark serial read calls as nonblocking.
The driver opens the port with SERIAL_NONBLOCK so these were already
nonblocking, and are handled appropriately.
2014-09-24 23:30:00 +02:00
Martin Ling 5305266a28 atten-pps3xxx: Remove SERIAL_NONBLOCK.
All serial read/write calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling c3116bc311 atten-pps3xxx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling e7b4103697 atten-pps3xxx: Make serial write call block in scan.
This is called at scan time so free to block. There is no partial write
handling and a response is expected afterwards. This should therefore be a
blocking call.
2014-09-24 23:30:00 +02:00
Martin Ling 25dd083128 appa-55ii: Mark serial read nonblocking and remove SERIAL_NONBLOCK.
This is the only read/write call in the driver. It is already non-blocking
and is handled appropriately.
2014-09-24 23:29:49 +02:00
Martin Ling 64c536be52 aglient-dmm: Remove SERIAL_NONBLOCK flag.
All serial calls in this driver are now explicitly (non)blocking.
2014-09-24 23:18:21 +02:00
Martin Ling a5053ddd21 agilent-dmm: Make serial write call block in send.
This call is executed from an event handler context was previously
nonblocking, however there is no handling for a partial write.

The output buffer is unlikely to be full and the commands to be sent
are short, so it should be OK to make this a blocking call.
2014-09-24 23:18:21 +02:00
Martin Ling 485b9ae34d agilent-dmm: Make serial write call block in scan.
This call is executed at scan time so is free to block. There is no
handling for a partial write and a response is expected immediately
afterwards. It should therefore be a blocking call.
2014-09-24 23:18:21 +02:00
Martin Ling e0b781a45b agilent-dmm: Mark serial read call as nonblocking.
This driver opens the port with the SERIAL_NONBLOCK flag, so this call is
already a nonblocking one, and is handled appropriately.
2014-09-24 23:18:21 +02:00
Martin Ling 2e360339f9 serial-dmm: Remove SERIAL_NONBLOCK flag.
All serial read/write calls in this driver are now explicitly
nonblocking so there is no need for this flag.
2014-09-24 23:18:20 +02:00
Martin Ling 4277ac349c serial-dmm: Mark serial read/write calls as nonblocking.
This driver opens the port with the SERIAL_NONBLOCK flag so these calls were
already non-blocking.
2014-09-24 23:18:20 +02:00
Martin Ling 02bd1d0298 colead-slm: Mark serial write call as blocking.
This driver opens the port without the SERIAL_NONBLOCK flag,
so this call was already blocking.
2014-09-24 23:18:20 +02:00
Martin Ling bbff0fe0d2 manson-hcs-3xxx: Mark serial read call as blocking.
This driver opens the port without the SERIAL_NONBLOCK flag, so this call is
already a blocking one.
2014-09-24 23:18:20 +02:00
Bert Vermeulen f12d997948 demo: Fix pattern mode and amplitude option publishing. 2014-09-23 22:40:47 +02:00
Bert Vermeulen 9a10ce65d6 colead-slm: Properly check acquisition sample limit. 2014-09-23 22:27:34 +02:00
Uwe Hermann af945a6625 Typos and consistency fixes. 2014-09-19 01:03:32 +02:00
Bert Vermeulen d4ccb6bd8f yokogawa-dlm: Don't implement dummy scan options. 2014-09-17 17:41:41 +02:00
Bert Vermeulen 5827f61b64 Publish config key capabilities.
Every driver now publishes its device option config keys, i.e. the
list fetched with sr_config_list(SR_CONF_DEVICE_OPTIONS), with a
set of flags indicating which methods are implemented by the driver
for that key.

The config keys are OR'ed with any combination of SR_CONF_GET,
SR_CONF_SET and SR_CONF_LIST. These are defined as the high bits
of the uint32_t config key. Clients can OR config keys with
SR_CONF_MASK to strip out these bits. This mask will be kept up to
date if other bits are added to the capabilities list; clients MUST
therefore use SR_CONF_MASK for this.

Some keys don't have capability bits added, such as the informative
device type keys (SR_CONF_MULTIMETER, SR_CONF_OSCILLOSCOPE, ...) and
SR_CONF_CONTINUOUS.

Scan options do not have capabilities bits.
2014-09-17 15:36:11 +02:00
Bert Vermeulen 138589b02e beaglelogic: Add missing scan options, and cleanup. 2014-09-16 23:51:38 +02:00