This separates the two options (drag/move) into different actions. Drag
will drag all graphical lines connected. Move will disconnect the
graphical lines when moving.
You can now enable and disable snap to grid when drawing/editing across
all apps. You can also tie snap to grid to the visibility of the grid
to allow rapid enable/disable via grid display.
1) use SCH_COMPONENT::GetRef(), GetValue() and GetFootprint() when
instance-specific info is needed
2) update UpdateAllScreenReferences() to handle value and footprint.
3) BACKANNO is CvPcb's handler, not back annotation's handler. Which
means it needs GUI behaviour, not back annotation behaviour.
Fixes https://gitlab.com/kicad/code/kicad/issues/5520
There was a regression in v6 where the zoom to selection toolbar
item wasn't canceling the tool when pressed and the tool was active
(it was in v5). This implements a more generic framework for canceling
tools on button presses.
Fixes https://gitlab.com/kicad/code/kicad/issues/5103
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)
Fixes https://gitlab.com/kicad/code/kicad/issues/5397
Using wxFileName::GetPath( wxPATH_WITH_SEPARATOR ) does not include the
drive specifier (A:, B:, C:, etc.) on windows which fails the comparison
with the project path 100% of the time. wxFileName::GetPathWithSep()
solves the issue nicely.
Fixes https://gitlab.com/kicad/code/kicad/issues/5077
Eeschema was the only application showing the file path. This is of
limited use and prevented other information from showing in the
shortened menubar display. Also combined strings for better translation
GitLab issue #5068 only affected the 5.1 branch. The same issue could
also affect master if for some reason a context switch occurs due to
changes. Moving the auto save feature before setting the current screen
to null should mitigate any potential future issues.
A subsheet may have more than one instance of a hier label,
but it's generally a mistake if there is no matching hier label
for a port on the parent sheet.
This is harder to do today now that we don't have manual tool
for placing hier ports, but it's still possible if you place
ports but then rename the label on the subsheet.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/3468
Display warning infobar in the board/schematic setup when no project
is loaded, since most of the settings in those dialogs are saved in
the project and not in the board/schematic file.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4868
Short net names are not unique; full names with paths must be used.
Added a grid cell renderer that does the escaping, to make it easier
to display net names in grid cells.
Once you unescape a net name, you can't go back to the escaped form
because you can't assume which `/` should be {slash} and which `/`
Because of this, we cannot use Unescape/Escape on the data model in
the netclass setup panel, and instead do the Unescape in the view.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5331
* Make the app progress indicator only have the indeterminate state
when the taskbar indicator is used (causes an uused variable warning
on wx<3.1)
* Remove unused dry run variable in pcb_netlist.h
* Remove unused forceDropAnnotations from the paste special dialog
since the dialog only controls keeping them.
CHANGED: When the output path is set in the plotter dialog, the user is
asked if they want to make the path relative to the project. The old
code would ask the user if they wanted to do this, and then if it
failed would present an error dialog. The new code tries it first on
a copy, and only if it works does the user get asked if they want
to do it.
Related to issue https://gitlab.com/kicad/code/kicad/issues/5263 except
that is for Pcbnew, and this fixes the same problem in Eeschema. Issue
5263 is fixed with Merge Request:
https://gitlab.com/kicad/code/kicad/-/merge_requests/370
This may affect other EDA_DRAW_FRAME objects as well but it doesn't seem
to be as noticeable in the symbol, footprint, and worksheet editors.
Fixes https://gitlab.com/kicad/code/kicad/issues/5248
When running the cleanup routine, we should check that we haven't
changed our lines during the process. If we have, we run again to pick
up the new merges
Fixes https://gitlab.com/kicad/code/kicad/issues/5265
Adding a component in eeschema accesses the footprint table as well as
the symbol table. There are no safe edits that can be taken while this
window is open, so we force it to be Modal instead of QuasiModal
The issue is addressed but reveals additional possible problems that
this commit fixes
Fixes https://gitlab.com/kicad/code/kicad/issues/5206
The use of printf, wxLogDebug, and std::err/std::out causes excessive
debugging output which makes finding specific debugging messages more
difficult than it needs to be.
There is still some debugging output in test code that really needs to
be moved into a unit test.
Add debugging output section to the coding policy regarding debugging
output.
* Frames moved: cvpcb, cvpcb footprints frame, gerbview, pagelayout editor
This also introduces new EDITOR_CONDITIONS that are used to set the
conditions of very common editor settings.
Also, some IDs were converted to tools in the pagelayout editor.
This allows for the tool framework to keep track of a universal
set of conditions for the UI state (enabled/checked/shown) for
controls of actions. It removes the need for the main menubar
menus to be CONDITIONAL_MENUs and be rebuilt on each open,
and instead makes the updates of the check and enabling of
items handled in the native wxWidgets way.
This commit switchs the 3d viewer and kicad project manager window
over to this system.
EDA_ITEM is a child of VIEW_ITEM, so a static_cast is not appropriate,
since in some cases it could be called with a non-EDA_ITEM argument.
This was triggering an ASAN heap-buffer-overflow in GerbView.
Cross-probing from Pcbnew to Eeschema revealed that EEschema was
including all fields, visible or not, when calculating the bounding
box of the probed componentt. This caused problems with long strings
such as URLs that were not set as visible. The cross-probing code
tries to minimize 'Zoom to Fit' operations when it's not necessary,
and the overly large bbox values often resulted in zooms not being
performed and components displayed very small.
This code adds a version of 'GetBoundingBox' that takes a boolean
to tell it to include invisble fields or not.
Addresses issue: https://gitlab.com/kicad/code/kicad/-/issues/5149
The parent symbol needs to be the same pointer as the symbol that is
saved to the cache otherwise the derived symbol will have it's parent
set to a parent that is not in the cache so it will not be saved.
Signed-off-by: Kevin Lannen <kevin.lannen@gmail.com>
The symbol editor did not actually update the parent symbol when the
dropdown in the properties editor was changed. This fixes that defect.
Signed-off-by: Kevin Lannen <kevin.lannen@gmail.com>
Previously, they were being interpreted as inches, and then being
displayed as mils - leading to a multiplication by 1000 if there
was no unit string included.
Fixes https://gitlab.com/kicad/code/kicad/issues/5117
This ensures the colors used by the status text pane in the preview
widget are the same as the canvas, so there is a seemless transition
between the two.
Additionally, remove the scrollbars from the symbol preview widget
in the place symbol dialog - they are pointless.
This is the proper fix for the symbole preview widget. It will ensure
there are no size changes between the two panels (preview and status),
and also ensure that the status panel has the same background color as
the preview panel.
Fixes https://gitlab.com/kicad/code/kicad/issues/4997
ADDED: Progress indicator in the taskbar
This adds a progress indicator to the Windows and macOS taskbar
icons to display the progress of some operations.
Note, this requires wxWidgets 3.1+
PROJECT objects will be deleted by SETTINGS_MANAGER::UnloadProject
so we need to make sure that this is called at an early enough point
in the closing process that anything needed by the PROJECT dtor
is still around.
Also fix an issue where the schematic worksheet was depending on
the project existing after the schematic had been reset.