Fixes#10926
Contains the following changes:
- Adds a new ERC_SCH_PIN_CONTEXT class which is used to provide deterministic
comparison between items causing ERC violations (e.g. pins) when associated
with a SCH_SHEET_PATH context.
- Adds association of SCH_SHEET_PATHs for ERC_ITEMs and the sub-schematic items
which caused an ERC violation. This allows correct display of markers on the
sheets of interest only, and allows correct naming resolution and cross-probing
from the ERC dialog.
- Adds a new ERC_TREE_MODEL class, derived from RC_TREE_MODEL, which correctly
resolves component references across heirarchical sheets using the associated
SCH_SHEET_PATHs. This allows sheet-specific component references to be displayed
correctly in the ERC results tree.
- Updates SCH_MARKER to only draw sheet-specific markers on the sheet causing
an ERC violation.
- Increments the schematic file version.
- When loading a schematic with legacy ERC exclusions, discards those of type
ERCE_PIN_TO_PIN_WARNING, ERCE_PIN_TO_PIN_ERROR, ERCE_HIERACHICAL_LABEL, and
ERCE_DIFFERENT_UNIT_NET as there is no safe way to automatically infer the
information which is now stored with these exclusions (sheet paths for error
location and related items). Requiring users to (once) re-add exclusions is
preferable to silently incorrectly matching new ERC issues to legacy exclusions.
When the designer asks to reset annotations, we reset all annotations
including power symbols. This may create additional churn in the files
but only when requested and is useful to fix schematic errors
Fixes https://gitlab.com/kicad/code/kicad/issues/13138
This iterated over all pins to find the pin after a given item. Because
out pattern is consistently to iterate in the outer loop, this means
that we were an O(n^2) loop for the pins just to find their names. This
affected very large parts (e.g. FPGAs) when switching sheets to display
This moves some stuff to REPORTER APIs. Moving more stuff would be good,
but it probably too high-risk at present. We'll wait for 8.0 for that....
Fixes https://gitlab.com/kicad/code/kicad/issues/13359
1) if a legacy model references a library then we need to see if said
libraray exists and read model from it if so
2) legacy node ordering is by index, not pin name
3) we can't auto-generate a pin map when we don't know the pin names,
so don't try
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.
Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).
Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
Currently this lives behind the advanced config flag `UseClipper2`.
Enabling this flag will route all Clipper-based calls through the
Clipper2 library instead of the older Clipper. The changes should be
mostly transparent.
Of note, Clipper2 does not utilize the `STRICTLY_SIMPLE` flag because
clipper1 did not actually guarantee a strictly simple polygon.
Currently we ignore this flag but we may decide to run strictly-simple
operations through a second NULL union to simplify the results as much
as possible.
Additionally, the inflation options are slightly different. We cannot
choose the fallback miter. The fallback miter is always square. This
only affects the CHAMFER_ACUTE_CORNERS option in inflate, which does not
appear to be used.
Lastly, we currently utilize the 64-bit integer coordinates for
calculations. This appears to still be faster than 32-bit calculations
in Clipper1 on a modern x86 system. This may not be the case for older
systems, particularly 32-bit systems.
pad of a given number.
Also improves other DRC logic to tighten up the net-tie rules now that
we know which pads are allowed to short with which other pads.
Also removes the "Overlapping pads" DRC violation now that we know
whether or not overlapping pads in a net-tie footprint constitute a
short.
Fixes https://gitlab.com/kicad/code/kicad/issues/12506
When the via is first and not second in our ordering, the hole-copper
clearance was not checked as the track did not have a hole.
We also calculated the NPTH-via clearance incorrectly in the inspector
All labels need to be attached to a net that has at least 2 pins in
order for this to be a valid net. To check for the existing pins, we
need to interate over all subgraphs in the net, counting pins
- Fix parsing .model lines with model names containingnon-alphanumeric
characters like - and _,
- Fix parsing libraries in which EOF is not preceded by a newline.
Fixes https://gitlab.com/kicad/code/kicad/issues/12394
Allows placing parts from an external database that reference symbols from another loaded library.
Includes:
- nanodbc wrapper
- database schematic library plugin
- basic tests
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7436
When wxAny holds an enum, it cannot be compared with an integer due to a
missing conversion function. In such case, conditional properties
compare a raw value rather than wxAny.
Introduces classes:
- INSPECTED: base class for types taking advantage of
generic properties system.
- PROPERTY*: meta-data storing information about properties
- PROPERTY_MANAGER: singleton class to get properties data