Pins are weak_ptrs to the library, so they require a lock() before
accessing. This imposes a performance hit on fast loops that access
the pin list repeatedly. This patch caches the pin position locally
for each component, updating only when needed.
Fixes: lp:1737363
* https://bugs.launchpad.net/kicad/+bug/1737363
COMPONENT_TREE::STATE used wxDataViewItem to store the selection, but it
will point to a deleted object if the selection was removed. Switched to
storing the selection using LIB_ID as it is much safer to use.
Show the NC box only on pins connected via the same component,
indicating a stacked pin group. Do not show NC box on pins for
different components with the same symbol.
If a schematic contains two symbols with the same name from different
libraries, the cache will contain the last symbol saved with that name.
Prepend the library nickname with the original schematic symbol library
nickname when saving the cache library to prevent name collisions.
With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded. This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.
Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.
Check the error message contents when no exception was caught to warn
the user of any accumulated errors.
Fixes lp:1690644
https://bugs.launchpad.net/kicad/+bug/1690644
Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
It turns out the fastest way to update wxDataViewCtrl is to nuke the
model and rebuild it from scratch rather than via
ItemAdded()/ItemDeleted() update notifications.
Fixes: lp:1734773
* https://bugs.launchpad.net/kicad/+bug/1734773
CHANGE: In Eeschema, when placing a component directly over an existing
wire, the wire is automatically removed where it shorted pins.
This helps workflow in Eeschema, allowing one to quickly add components
to existing lines.
Fixes: lp:1678449
* https://bugs.launchpad.net/kicad/+bug/1678449
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic
SCH_LINE can represent a bus, wire or graphic line. Checking
for the corner needs to distinguish between these types.
Fixes: lp:1635984
* https://bugs.launchpad.net/kicad/+bug/1635984
Make the user prompt an HTML control for improved layout.
Fix some column title sizing issues. This is not a complete fix but
it seems better than the default sizing done by wxWidgets.
Use symbol terminology instead of part and/or component.
Create trace string source files for a common place for them and their
Doxygen comments.
Don't back up schematic files unless the user requests a remap.
Back up all files that could be changed by a remap including the
schematic file(s), cache library, project file, and rescue library
files.
Use an HTML control instead of a static text control for improved layout
of the user remap prompt.
Improve the user prompt in the remap dialog to make it clear that changes
will be made to project files.
Duplicated aliases were given " (copy x)" suffix. There are two
problems: aliases cannot contain spaces and the string was translatable
which could create more issues. Now duplicated aliases receive "_x" suffix.
Change the legacy schematic plugin to preserve illegal LIB_ID characters
when load schematics prior to version 4.
Check for illegal LIB_ID symbol names during project rescue. Rename and
rescue any symbols with illegal LIB_ID names.
Add static methods to LIB_ID object for testing for and fixing names
with illegal characters so there is uniform code for doing so.
Update the Eagle plugin symbol loader to fix symbol names using the new
LIB_ID fix illegal names method.
Fixes lp:1732236
https://bugs.launchpad.net/kicad/+bug/1732236
Dragging a full line that is connected to a component
now drags the component as part of the block, maintaining
connections.
Fixes: lp:1167714
* https://bugs.launchpad.net/kicad/+bug/1167714
Removed cut & copy toolbar icons in the schematic editor, as they
were inaccessible. One cannot have an item selected and move the
mouse outside the canvas area due to autopanning.
Added paste icon to the library editor.
Tree nodes now have an additional field 'InTree' to determine
if the view is aware of its existence. This way, there is no need
to rebuild the data structures from scratch when they need to be
filtered.
Library Editor updates its working copy of the edited part every time
it is modified. If LIB_EDIT_FRAME::PlacePin() calls OnModify() too early,
the working copy does not include the last change.
Updates LIB_ID::LibItemName field when a part is renamed and LIB_PART
name when a new LIB_ID is set.
Similarly, LIB_ID::LibNickName field is updated when a library set, but
there is no easy way to assign library when LIB_ID::LibNickName is
modified.
LIB_PART name is stored in three places that might be changed
independently:
- the first LIB_ALIAS in m_aliases
- LIB_FIELD with VALUE ID
- m_name wxString field
This is potentially leads to an incoherent LIB_PART state. To prevent
this, all fields are changed using only one method: LIB_PART::SetName().
LIB_PART::m_name has been removed as the same information is available
in two other variables.
Handle exception in best zoom method when a symbol could not be loaded
from the symbol library table. This was triggered by an empty symbol
library table but could be triggered by any exception thrown while
loading the symbol.
Fixes lp:1733111
https://bugs.launchpad.net/kicad/+bug/1733111
Remove the placeholders for the upcoming s-expression schematic and
symbol library file format plugin type. The lack of a valid plugin
implementation was causing an undefined plugin type string in the
plugin type selection cell when new rows were added to the table.
Fixes lp:1733116
https://bugs.launchpad.net/kicad/+bug/1733116
SEARCH_STACK is a deprecated method for getting the list of paths where
one could look for a file. Instead it tries the project path and
environmental variables.
All of the schematic object load and save code is implemented in the
legacy schematic plugin so it is no longer required.
Remove unused file with old schematic file loader.
Doxygen comment cleaning.
Use the legacy plugin schematic loader in the sheet edit and append
schematic code paths.
Check for fully qualified LIB_ID objects (must have library nickname)
when loading existing schematics when edit sheets.
Rewrite append schematic feature to handle import issues rather than
change the name and file name of all of the sheets in the imported
schematic. This includes the following:
- Load the schematic into a temporary SCH_SHEET object.
- Make sure the imported schematic does not cause any hierarchy
recursion issues.
- Verify the imported schematic uses fully qualified #LIB_ID objects
(symbol library table).
- Check to see if any symbol libraries need to be added to the current
project's symbol library table. This includes:
- Check if the symbol library already exists in the project or global
symbol library table.
- Convert symbol library URLS that use the ${KIPRJMOD} environment
variable to absolute paths. ${KIPRJMOD} will not be the same for
this project.
- Check for duplicate symbol library nicknames and change the new symbol
library nickname to prevent library name clashes.
- Update all schematic symbol LIB_ID object library nicknames when the
library nickname was changed to prevent clashes.
- Check for duplicate sheet names which is illegal and automatically
rename any duplicate sheets in the imported schematic.
- Clear all of the annotation in the imported schematic to prevent
clashes.
- Append the objects from the temporary sheet to the current page.
- Replace any duplicate time stamps.
- Refresh the symbol library links.
Add support code to SCH_SCREEN object to assist with schematic import.
Doxygen comment cleaning.
Fixes lp:1731760
https://bugs.launchpad.net/kicad/+bug/1731760
Do not attempt to normalize environment variables that are not valid
paths, paths that do not exist, or paths that the user does not have
read access to.
Fixes lp:1731655
https://bugs.launchpad.net/kicad/+bug/1731655
Dotted, dashed and dash-dot lines are provided in
HPGL, PDF, PS and SVG plot outputs along with line
width and color formatting.
DXF format does not currently provide any dashed
line functionality
A bug in HPGL plotted is corrected. Previous HPGL
dashed line commands were incorrect, plotting all
lines as solid.
The GTK+ file dialog is case sensitive however it does support regular
expressions. Most of the file dialog wildcards are lower case so only
files with the lower case extensions will show up in the file dialog.
This code adds a method to convert file extensions of any case to the
appropriate (sch -> [sS][cC][hH]) regular expression on GTK+ builds so
all file extension case combinations will show up in the file dialog.
A note to developers: make sure to add a file extension when setting
when setting the default file argument. If you do don't set an
extension, the GTK+ file dialog will happily append the regular
expression as the file extension which is surely not what you want.
There are still a few known places (mostly gerbview) where there are
some complex wildcard code that has not been converted.
Fixes lp:1720542
https://bugs.launchpad.net/kicad/+bug/1720542
The replaced wxASSERTs notify the developer that a variable is a
null pointer, but continue code execution and lead to a crash.
Instead, they are changed to wxCHECKs, that give the same type
of notification, but return from a function before the crash
happens.