Normal SetValue() call would temporarily change the displayed
value, but as soon as the text widget receives focus again, the original
expression (not evaluated) is restored.
To avoid this, the original expression is cleared in the associated
NumericEvaluator object.
If ',' is used as decimal separator by the current locale a '.' is also accepted.
Also add support for units "mi", "th" and "in" as described in the documentation of pcbnew.
Fixes: lp:1751315
* https://bugs.launchpad.net/kicad/+bug/1751315
Frame, dialog and config file couldn't agree on whether to use
internal units or not.
Frame now stores internal units, and they're now mapped on the
way in/out of the config file. Dialog was already assuming they
were stored in internal units (though they were previuosly not).
Fixes: lp:1751435
* https://bugs.launchpad.net/kicad/+bug/1751435
Too many external applications fail to touch the parent directory.
Also removes FP_CACHE_ITEM lastMod times and dirty flags as we've
always loaded libraries atomically anyway.
Claws back some of the performance lost by being more efficient
with cache management for sequential calls to Enumerate and then
Load.
Fixes: lp:1750936
* https://bugs.launchpad.net/kicad/+bug/1750936
Add a library selector to the save dialog. Initialize it to the
footprint's library. This way a straigh-up save will do what's
expected.
However, the user can still select the active library (or any
other library) if they really did want to move the footprint.
Fixes: lp:1750918
* https://bugs.launchpad.net/kicad/+bug/1750918
Also adds indicators in layers palette for feedback.
Also generates sized images for all indicators instead of using
scaled bitmaps (which didn't look great).
Also fixes a completely unrelated typo in a UI string.
Also fixes:
- forcing the annotation scope to "full schematic" when run
as a prerequisite to Generate Netlist.
- a long-standing bug where displaying extra items in a dialog
would mess up the height of the HTML_REPORT_PANEL (becasue
we were setting the html window's height rather than its
parent flexgrid.
- initializing the annotation radio buttons to safe values
(full schematic and keep existing)
Fixes: lp:1750062
* https://bugs.launchpad.net/kicad/+bug/1750062
NEW: add new align icons based on the existing align_items.svg icon, just flipped and rotated
CHANGED: change the context menu to use the new align icons
After Eagle project import, schematic and board netlists are inconsistent:
footprints do not have sheetpaths assigned, schematics are unannotated.
One can update netlist either by references or timestamps, but timestamps
are empty in pcbnew, and updating by reference must by preceded by
annotation which may lead to broken links between board and schematics
(Eagle does not require references to end with a number, so KiCad annotater
will add numbers in such cases).
To fix the problem, there is a two step netlist update:
- update by reference without the annotation step, to assign
correct sheetpaths to footprints
- update by timestamp, after symbols are annotated, in order to
update references in the board
Fixes: lp:1748502
* https://bugs.launchpad.net/kicad/+bug/1748502