Commit Graph

408 Commits

Author SHA1 Message Date
Jeff Young 91e876ce0d Make sure the title is updated when file is saved/reverted/etc.
Fixes https://gitlab.com/kicad/code/kicad/issues/7626
2021-02-20 15:09:47 +00:00
Jeff Young 1a36971583 Remove higher-level write-protected check. It's now done lower down.
Fixes https://gitlab.com/kicad/code/kicad/issues/5937
2021-02-19 21:46:06 +00:00
Seth Hillbrand dbbe9cdee4 Hide infobar for save when saving 2021-02-16 15:54:43 -08:00
Roberto Fernandez Bautista 2c04d76ff4 Non-Kicad Schematic Importers: Do not reload all symbols after import
This is required to allow handling of pin swaps in the CADSTAR importer
2021-02-10 18:49:20 +00:00
RigoLigoRLC afad1625d7 Fix save-as extension of imported schematics
Fixes https://gitlab.com/kicad/code/kicad/issues/7333
2021-02-01 18:34:59 +00:00
Jeff Young dfc6070178 Unify schematic file version checking with PCBNew.
This also makes sure that the user gets a warning before saving over
an older s-expr format.  While that won't always be wanted, it's now
in the infobar (like in PCBNew), so it's not too onerous.§

Fixes https://gitlab.com/kicad/code/kicad/issues/7347
2021-01-31 17:28:14 +00:00
Mikolaj Wielgus 8eca23aabe Mark null project initial screen as zoom-initialized
The variable `m_Initialized` in `BASE_SCREEN` is used by
`SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized
by the "zoom to fit screen" action. When this variable is `false`, the
function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit
screen", modifying the zoom level. This function is indirectly called in
the undo routines, so if `m_Initialized` is not set to `true`, a zoom
change will occur when the user undoes an operation, a behavior that is
undesired.

`m_Initialized` was not initialized to `true` for the null schematic
(the schematic that is loaded if no project is loaded), causing the
aforementioned undesired behavior.

To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set
`m_Initialized` to `true`, since it zooms to fit screen already. I've
moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used
only in Eeschema, and renamed it to `m_zoomInitialized`, a name I
believe that better describes what this variable does.

I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to
group the "zoom to fit screen" action with setting `m_Initialized` to
`true`, as they often should occur together.

I'd also like to say that I'm not confident whether
`SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level
initialization at this point, but I have decided to not change this
behavior for now, as the commit history suggests it's several years old.

Fixes https://gitlab.com/kicad/code/kicad/issues/7343
2021-01-31 00:49:11 +00:00
Marek Roszko e6dd95e83a Create a default user projects folder 2021-01-27 19:12:18 -05:00
Konstantin Baranovskiy cd2c46e5c9 Make "... file is read only." warnings translatable. 2021-01-12 14:33:35 +00:00
Ola Rinta-Koski 87b2081807 Set sheet file name when Save as... succeeds
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6561
2021-01-06 19:29:18 +00:00
jean-pierre charras eb7dc6ddd9 Minor fixes. In stand alone show the frame as soon as possible.
Especially when running Pcbnew to open a complex board the frame is shown faster.
Add also a busy cursor when loading files and building the data.
2020-12-21 17:44:10 +01:00
Jeff Young bb232e6ac6 Unify LIB_IDs now that both are stored in sexpr files.
Fixes https://gitlab.com/kicad/code/kicad/issues/6764
2020-12-18 00:30:26 +00:00
Jon Evans a484d10470 Ensure schematic autosave works if sheet path is invalid 2020-12-16 21:17:48 -05:00
Marek Roszko d67cf2f9af Replace wxFile usage with wxFFile
Buffered libc wxFFile is better thinking about syscall wxFile going wrong.
2020-12-12 13:16:23 -05:00
Marek Roszko ad1aae40ec Unify the saved file strings 2020-12-08 19:49:47 -05:00
Marek Roszko abb5cb8310 Fix up msg panel status on save slightly
- pcbnew should use status bar on success like eeschema
- Add a helper to clear msgpanel and set it in one go to avoid redraw delays due to doing processing in between
2020-12-08 00:28:07 -05:00
Jeff Young ad281f7538 Remove duplicated TestDanglingEnds routines.
Also adds a changedItemHandler so that the single remaining version
can update the view.

Fixes https://gitlab.com/kicad/code/kicad/issues/6581
2020-12-06 21:24:16 +00:00
Jeff Young 3da0ab1a9a Fix a couple of bugs in intersheet references.
1) init reference pages before trying to draw the SCH_FIELDs when
turning intersheet references on

2) don't double redraw because we accidentally cleared the last
hover item on a non-mouse-moved event.

3) make sure the root sheet gets a name for the hypertext menu.
2020-11-29 16:53:18 +00:00
Jeff Young c2ba68cdfa Make sure intersheet references are updated on file-open. 2020-11-19 19:21:15 +00:00
Jeff Young 826e47dde3 Hook up excluded ERC marker persistence.
Fixes https://gitlab.com/kicad/code/kicad/issues/6425
2020-11-19 18:22:52 +00:00
Jeff Young f0d0e17aab Prepare for MODULE -> FOOTPRINT. 2020-11-13 15:16:24 +00:00
Jeff Young 5507575d64 Move ERC dialog to EE_INSPECTION_TOOL and kill when resetting.
Fixes https://gitlab.com/kicad/code/kicad/issues/6111
2020-11-03 20:27:44 +00:00
Jon Evans 2153a7655b Try harder not to give a read-only path to save dialog
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5937
2020-10-21 20:55:43 -04:00
Wayne Stambaugh 8ff51d8899 Eeschema: add schematic sheet page number.
The groundwork has now been laid for per sheet instance data.  Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.

ADDED: Support for user defined schematic page numbers.
2020-10-19 14:05:45 -04:00
Marek Roszko 2c86363aa0 Relocate the page_layout includes to a page_layout folder 2020-10-13 20:33:33 -04:00
Jon Evans 7b5d628e4b Eeschema: fix save-as dispatching from new file
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5937
2020-10-12 20:06:55 -04:00
Michael Kavanagh c40483d18a Cleanup: Move KiCad files into plugins folder 2020-10-12 16:36:08 +00:00
Jon Evans 76bfa47a77 Allow creating new projects when doing a Save As in eeschema 2020-10-05 22:36:26 -04:00
Michael Kavanagh 1416280662 Cleanup: Move Eagle files into plugins folder 2020-10-05 14:19:07 +00:00
Roberto Fernandez Bautista ab18c8e219 eeschema: Add "All supported formats" drop-down to the "Import Non Kicad Schematic" file dialog 2020-10-03 02:19:13 +00:00
Franck Jullien 2fc49045d1 ADDED: eeschema: Add intersheets references function
Add a new function to place intersheets references next to
global labels.
2020-10-01 20:39:32 +00:00
PJM 7dc1966a0d Eeschema: Fix text formatting in "Project Load Warning" dialog
CHANGED: When the "Show Details" button on the "Project Load Warning"
dialog is clicked, it reveals text that has odd formatting of when
lines split.  This commit fixes the text for the dialogs that warn
that schematics will be saved in the new file format, and that Symbol
Libraries defined in the project file symbol library list are no longer
supported.
2020-09-29 00:31:13 -07:00
Roberto Fernandez Bautista 2d99703e28 CADSTAR Schematic Archive Importer: Load all Sheets and Hierarchical Blocks 2020-09-27 18:13:58 +01:00
Roberto Fernandez Bautista 721cba32d5 ADDED: CADSTAR Schematic Archive Importer
Initial commit to trigger the importer
2020-09-27 18:13:57 +01:00
Jeff Young 133fb5cded Minor code cleanup. 2020-09-06 11:28:58 +01:00
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Wayne Stambaugh c17f832de1 Eeschema: move auto save check before clearing current screen.
GitLab issue #5068 only affected the 5.1 branch.  The same issue could
also affect master if for some reason a context switch occurs due to
changes.  Moving the auto save feature before setting the current screen
to null should mitigate any potential future issues.
2020-09-01 16:52:05 -04:00
Mark Roszko 9f128f942c Move shutdown blocker to kiplatform 2020-09-01 10:14:51 +00:00
Jon Evans 9f7bca38b3 A better way of handling standalone project files 2020-08-30 16:04:39 -04:00
Jon Evans 24435fcc62 Don't create new project files when opening boards/schematics
Display warning infobar in the board/schematic setup when no project
is loaded, since most of the settings in those dialogs are saved in
the project and not in the board/schematic file.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/4868
2020-08-24 22:17:21 -04:00
Mark Roszko 89e74140eb Save file / window states for kicad project locally 2020-08-24 02:01:14 +00:00
Thomas Pointhuber a03fb7a9a8 Altium: Refactor and add initial structure for schematic importer
altium: move pcbnew/altium2kicadpcb_plugin -> pcbnew/plugins/altium

See: https://gitlab.com/kicad/code/kicad/-/issues/4412
2020-08-23 19:01:08 +00:00
Jeff Young f4ab14f32d Performance improvements for SchematicCleanup().
Fixes https://gitlab.com/kicad/code/kicad/issues/4563
2020-08-10 12:41:52 +01:00
Jeff Young f3b92903e2 Evidently the sheet client list isn't kept up-to-date.
Fixes https://gitlab.com/kicad/code/kicad/issues/5021
2020-08-02 19:58:15 +01:00
Jeff Young 173493b1a8 Try to store the actual sheet #, but don't store 1 for non-root sheet.
Fixes https://gitlab.com/kicad/code/kicad/issues/5021
2020-07-31 22:29:05 +01:00
Marek Roszko 9278660b10 Add support for the windows application restart api 2020-07-28 14:32:39 -04:00
Jeff Young 7340c97ef9 Undo for schematic-wide operations.
Editing value/footprint fields of multi-unit components.
Find/Change.
Annotation.
Back annotation.

Fixes https://gitlab.com/kicad/code/kicad/issues/2122

Fixes https://gitlab.com/kicad/code/kicad/issues/4869

Fixes https://gitlab.com/kicad/code/kicad/issues/3933

Fixes https://gitlab.com/kicad/code/kicad/issues/4871

Fixes https://gitlab.com/kicad/code/kicad/issues/3899
2020-07-13 12:32:17 +01:00
Jon Evans a2041073ee Skip project backup in standalone mode
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4867
2020-07-12 11:42:05 -04:00
Jon Evans fc92fb076e Cache sheet path to string conversion in UpdateSymbolInstances
Profiling of large designs (with many hierarchical sheets)
showed that this can be a huge (4x) speed up to schematic
loading times.
2020-07-09 18:14:37 -04:00
Jon Evans b1b9cef5fb Full-project automatic backup system
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4763
2020-07-09 13:55:19 +00:00
Jon Evans 788f31d743 Fix import of Eagle schematics
Old project needs to be unloaded before schematic is reset,
then new project has to be loaded before doing the import

Fixes https://gitlab.com/kicad/code/kicad/-/issues/4836
2020-07-07 20:48:32 -04:00
Jeff Young 509cd8f495 Remove duplicate fix not found by merge. 2020-07-05 21:01:19 +01:00
Jeff Young ec6c1b80b7 Fix a couple of bugs in the CurrentSheet architecture. 2020-07-05 19:53:04 +01:00
Jon Evans 04a51a5ba4 Push current sheet handling to SCHEMATIC
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4803
2020-07-04 20:59:35 -04:00
Jon Evans 0201cb4e7e Fix schematic reload in standalone mode 2020-07-03 10:43:23 -04:00
Jon Evans 498fa8d8ba Fix some things about template fieldname synchronization 2020-07-02 23:42:36 -04:00
Jon Evans 4dbbe1cf68 Project settings fixes from review
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
2020-07-02 22:08:54 -04:00
Jon Evans fe5959b625 Remove the schematic and board backup file system
Per discussion on the developers list, this old system
no longer provides much value and is seen as annoying
by many users.  The new save logic should prevent any
cases of file corruption on save, which was a major
reason for the backup file system existing.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2012
2020-07-02 22:08:54 -04:00
Jon Evans 12b4a55ae8 Port Eeschema to new project settings
DRC/ERC error serialization changed to use explicit tokens
Old stored severities and ignored errors are discarded
2020-07-02 22:08:54 -04:00
Jon Evans c0aa6965de Migrate PcbNew project settings to new framework
Various architecture upgrades to support this.
Creating a BOARD now requires a valid PROJECT, which caused
some (mostly transparent) changes to the Python API internals.

ADDED: Project local settings file
CHANGED: Board design settings are no longer stored in PCB file
CHANGED: Net classes are no longer stored in PCB file
CHANGED: Importing board settings now reads boards, not just projects

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2578
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4070
2020-07-02 22:08:54 -04:00
Jon Evans 0e2f9cb1bd Migrate CvPcb project parameters 2020-07-02 22:08:54 -04:00
Jon Evans a4fadfcdf2 Begin moving project file load to new system 2020-07-02 22:08:54 -04:00
Jon Evans a7708fa6dc Add PROJECT_FILE and basic load/unload methods 2020-07-02 22:08:54 -04:00
Jon Evans 09cb75b8a1 Use a temporary file when saving boards/schematics to make the operation more atomic
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4517
2020-06-19 23:31:26 +00:00
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Wayne Stambaugh b624c7090a Deprecate saving legacy schematic and symbol library file formats.
REMOVED: The ability to save schematics in the legacy file format.
2020-05-29 12:43:00 +00:00
Jon Evans e934f8b459 Remove python netlist QA facilities 2020-05-23 22:48:09 -04:00
Jon Evans a63df2fbf0 Remove BuildNetListBase from netlisting paths 2020-05-23 13:14:05 -04:00
Jon Evans 2499a1d640 Remove KIWAY dependence from SCH_PLUGINs 2020-05-20 23:00:23 -04:00
Jon Evans b074cdf185 Ensure that eeschema loads project params in standalone mode 2020-05-19 23:57:53 -04:00
Ian McInerney 73a1ce3e84 Move eeschema find notification to the infobar and improve the infobar widget
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time

CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
2020-05-20 02:31:47 +01:00
Wayne Stambaugh 28b8e75211 Fix duplicate time stamp bug when loading legacy schematics. 2020-05-19 11:01:00 -04:00
Ian McInerney a2f027e063 Add an infobar widget to display information above the canvas
This widget allows for non-intrusive display of text
above the editing canvas. Currently, this is used
for displaying the read only status of the files.
2020-05-19 00:46:33 +01:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 84160c1da4 Fix typo.
Fixes https://gitlab.com/kicad/code/kicad/issues/4448
2020-05-15 00:27:19 +01:00
jean-pierre charras 2cf82d9129 fix a wxWidgets minor alert and compil warnings 2020-05-13 08:53:32 +02:00
Jeff Young 724c669434 Move a few more commands to tool framework. 2020-05-12 18:12:38 +01:00
jean-pierre charras bc24d8e957 Fix typo and I18N string 2020-05-10 16:55:15 +02:00
Wayne Stambaugh e253862f77 Eeschema: remove automatic conversion of time stamp UUIDs.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed.  If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.

The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost.  This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
2020-05-07 09:26:43 -04:00
Wayne Stambaugh 9c99286385 Fix a few Coverity warnings. 2020-05-05 16:42:59 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jon Evans 2eaefb4874 Improve performance of schematic load and connectivity
Store component paths and references efficiently
Remove redundant calls to RecalculateConnections
2020-04-30 19:53:25 +00:00
Jon Evans b802a3e776 Add command-line option to generate netlist and exit 2020-04-19 19:13:24 -04:00
Jeff Young 2b6089240a Change super/subscript syntax to ^{foo} and _{foo}. 2020-04-18 21:04:41 +01:00
Jeff Young 9c8941e040 Remove a bunch of globals. 2020-04-16 17:34:46 +01:00
Jeff Young 122b1ddaae Unwrap an unnecessary layer now that we have new config stuff. 2020-04-13 20:58:12 +01:00
Wayne Stambaugh 2f682b6c5f Eeschema: implement s-expression schematic file format parser.
Fix a few issues with the s-expression schematic file formatter.
2020-04-06 22:47:42 +00:00
Jeff Young b13559c926 Add envVar and text variable resolution to plot directory paths.
Fixes https://gitlab.com/kicad/code/kicad/issues/3808
2020-04-05 23:56:24 +01:00
jean-pierre charras b1b8a32078 fix a few Coverity warnings and compil minor warnings. 2020-04-03 09:54:47 +02:00
Wayne Stambaugh 7dc64f08b7 Eeschema: implement s-expression schematic file formatter.
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format.  Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
2020-03-16 09:05:16 -04:00
Jeff Young 85c2e0d23a Add user-defined severities, exclusions and colors to DRC markers.
Exclusions are currently persisted in the project file.

Fixes https://gitlab.com/kicad/code/kicad/issues/1989
2020-03-04 00:39:28 +00:00
Jeff Young 490f39a671 Remove obsolete code requiring unique sheet names. 2020-02-20 22:56:11 +00:00
Jeff Young 81dd1d7a68 Timestamp-based paths were ugly. UUID-based ones are worse.
Show a human-readable path in the Edit Footprint dialog.
2020-02-20 21:29:52 +00:00
Jon Evans e59a3d981e Implement a new settings framework across all of KiCad
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme

Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
2020-02-19 23:44:56 -05:00
Seth Hillbrand 6e5e453d0d Replace EESchema DLIST
This moves EESchema DLIST structures to rtree.  These changes are more
fundamental than the pcbnew changes from 9163ac543 888c01d11 d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
2020-01-10 06:37:08 -08:00
Ian McInerney 079423c3cc eeschema: Remove unused include of eeschema_id.h 2020-01-03 16:04:54 +00:00
Mark Roszko 686b768a3d Add shutdown blocking on Windows for pcbnew, eeschema and pleditor
ADDED: Block shutdown/logoff on Windows when contents have been modified
2019-12-19 14:11:11 +00:00
Wayne Stambaugh 30da2b31ea Eeschema: fix multiple symbol rescue bug caused by commit 54f066fe.
Use the root symbol when comparing against the cached symbol when
checking to see if a symbol changed.  When the original symbol is
a derived symbol, the test will always fail.

Force a symbol link refresh on a rescue to prevent stale links from
crashing the connection graph refresh when running the project rescue
on demand.

Force a symbol link refresh on project load to prevent stale links from
symbol link changes from crashing the connection graph when the project
rescue in invoked.

Fixes kicad/code/kicad#3645
2019-12-09 14:47:29 -05:00
Jeff Young 9d288968e7 Be more explicit about extent of schematic cleanups.
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack.  Needless to say, this
was a recipie for segfaults.

Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
2019-11-10 23:25:54 +00:00
Wayne Stambaugh 8789ab9265 Eeschema: remove rogue symbol libraries from project file.
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.

Add nagware dialog to warn the user and a checkbox to never show the
dialog again.

Fixes lp:1838185

https://bugs.launchpad.net/kicad/+bug/1838185
2019-08-01 13:26:21 -04:00
Wayne Stambaugh b595dc0d3b Eeschema: fix edit sheet bug.
Remove an existing sheet from the current page that requires a schematic
load from file to prevent a corrupt screen list from causing a segfault.

Merge the edit sheet file loading with the append schematic code since
they are functionally the same.  This allows the sheet edit code to
take advantage of all of the added broken symbol library links added in
the recent append schematic fixes.

Fixes lp:1835841

https://bugs.launchpad.net/kicad/+bug/1835841
2019-07-30 08:21:33 -04:00
Seth Hillbrand 7759ad7e27 eeschema: Clean up backup name
This fixes the last suffix that was missed by 168fa09f5.  The schematic
backup files should have the suffix .sch-bak to distinguish from
.kicad_pcb-bak or other backups.

(cherry picked from commit b6fe4ff637)
2019-07-23 16:15:04 -07:00
Wayne Stambaugh 9fae30162d Eeschema: fix many append schematic bugs.
Do not add cache library from another project to old library list.  This
is wrong and can cause all kinds of symbol library linking issues.  It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.

Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended.  If the path can be relative,
give the user the option to use either relative or absolute paths.

Do not change symbol library names in schematics appended from a source
outside the current project.  This will almost ensure the symbol library
links will be broken in the source project.

When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.

When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
2019-07-19 11:39:29 -04:00
Tomasz Włostowski d7fe307913 eeschema: automatically insert junctions at pin connections if needed during file load
EEschema optimizes wires by merging colinear segments. If a schematic opened without a valid
cache library or missing installed libraries and later saved, this optimization can cause connectivity
errors. In order to fix that we check each pin-wire connection and junctions if necessary.
2019-06-25 01:06:25 +02:00
Jeff Young 4eab89d9ef Fix OSX button order issue in Unsaved Changes dialog.
Also changes the presentation of the string when the checkbox appears
so that the "Changes will be lost" warning isn't hidden by the turndown.
This last part may require conditional compilation as it's undocumented.

Lastly, regularizes the Unsaved Changes strings between the apps.
2019-06-17 17:01:57 +01:00
Jeff Young 1ea001d497 Go back to event-loop zooming for new frames.
The immediate mode appears to have made things worse not better.
2019-06-04 13:56:54 +01:00
Jeff Young bdd44ce88c Use consistent PageLayout data structure names. 2019-05-27 11:55:58 +01:00
Jeff Young a3dfce5adb Implement common file menu actions and move Eeschema over. 2019-05-25 01:14:21 +01:00
Jeff Young 323bb0f8e1 Moving PageLayout editor to GAL canvas and modern toolset. 2019-05-24 19:49:09 +01:00
Seth Hillbrand b53b29399d eeschema: Ensure conn is updated after import
After importing Eagle files, we need to make sure that the connectivity
network is updated before the system requests a new netlist.  Otherwise,
we end up with different results from the first to second updates.
2019-05-21 19:31:59 -07:00
Tomasz Włostowski aff3243f3b eeschema: fix use-after-free crash in GetScreen()/GetCurrentSheet() 2019-05-20 21:04:46 +02:00
Jeff Young e850592587 Cleanup. 2019-05-15 17:50:52 +01:00
Jeff Young 7995b5cc3c Restore selection on abort and undo/redo.
Also includes a related bug fix to not create an undo record for
the initial schematic cleanup.

Fixes: lp:1825975
* https://bugs.launchpad.net/kicad/+bug/1825975
2019-05-11 15:38:49 +01:00
Jeff Young 0c2ba94b16 More sharing between SchEdit and LibEdit. 2019-05-10 20:22:26 +01:00
Jon Evans 9589427960 Refactor how at-load schematic normalization is called
Don't prepend "/" for nets at the top level

Revert "Don't prepend "/" for nets at the top level"

This reverts commit fa9533222f7d33eee5f3fa2320bd9f3167e28076.
2019-03-31 19:57:00 -04:00
Jon Evans 3c714f1d8c Fix undo handling of SchematicCleanUp 2019-03-31 19:55:57 -04:00
Jon Evans 83c7e7fc65 New connectivity algorithm and bus upgrades
Bus upgrades: core new connectivity code

Bus upgrades: eeschema integration and modifications

Bus upgrades: eeschema dialogs

Bus upgrades: netlist export

Bus upgrades: file format changes
2019-03-31 19:53:41 -04:00
Seth Hillbrand 078320e2fb Unify and correct Autosave functions
Autosave was not working correctly, partly due to different
implementations in eeschema and pcbnew and partly due to a mistaken
refactor at some point during v5 development.  This unifies the expected
autosave prefix to _autosave- for both pcbnew and eeschema.  It also
unifies the expected suffix for the backup files to -bak.

Fixes: lp:1820433
* https://bugs.launchpad.net/kicad/+bug/1820433
2019-03-18 10:25:26 -07:00
jean-pierre charras bec2d7861e Eeschema: shows the opened sheet info in title bar.
Fixes: lp:1819564
https://bugs.launchpad.net/kicad/+bug/1819564
2019-03-15 13:09:04 +01:00
Wayne Stambaugh 44cb979e91 Decouple SCH_EDIT_FRAME from symbol rescue and remap dialogs.
Do not keep pointer to SCH_EDIT_FRAME in the rescuer object to prevent
it from creating dialogs with itself as the parent when call from the
rescue dialog which is itself a grandchild of the frame window.
2019-02-05 12:43:46 -05:00
Seth Hillbrand 88d9f946a2 eeschema: Don't break Eagle junctions on import
Eagle can label nets independently of the connection point position.  In
an "interestingly" designed circuit, this can lead to a junction of a
pin, wire endpoint and unrelated wire.  While this is bad practice,
KiCad shouldn't force an incorrect net connection during the import.  In
this case, we skip the addition of junctions to ensure that we don't
create a schematic error.

Fixes: lp:1788019
* https://bugs.launchpad.net/kicad/+bug/1788019
2019-01-30 17:02:24 -08:00
Maciej Suminski 7e1498a46f Set the screen pointer to null before deleting the associated items
VIEW needs to be cleared before deleting the stored items. Otherwise it
may dereference stale pointers leading to a crash.
2018-12-11 16:21:43 +01:00
Wayne Stambaugh 07ebc4df14 Fix schematic append clear annotation bug.
Clear the annotation of only the appended schematic and any sheets in it's
hierarchy.  Do not clear the annotation of the symbols in the target sheet.

Fixes lp:1805695

https://bugs.launchpad.net/kicad/+bug/1805695
2018-12-05 17:12:11 -05:00
Jeff Young 984d3f04ab Update dangling ends after importing schematic content.
Fixes: lp:1803996
* https://bugs.launchpad.net/kicad/+bug/1803996
2018-11-19 20:47:31 +00:00
Maciej Suminski 8091573bf7 Fix disappearing schematic components
SCH_COMPONENTs should be added to VIEW only when symbol links are
resolved. Otherwise a dummy component bounding box will be used when
inserting a component to VIEW R-tree.

Fixes: lp:1801800
* https://bugs.launchpad.net/kicad/+bug/1801800
2018-11-06 11:25:47 +01:00
jean-pierre charras d953724365 Eeschema: fix bug: append schematic does not update canvas
Fixes: lp:1800144
https://bugs.launchpad.net/kicad/+bug/1800144
2018-10-26 16:42:14 +02:00
Wayne Stambaugh b9a9fe6c9e Eeschema, remove option to import schematic that has not been remapped.
When importing an existing schematic into a sheet that was no remapped
to use the symbol library table, the user was given the option to ignore
the warning and proceed with the import.  This would end up with all of
the imported symbol links being broke.  In hindsight, this was a bad
idea so now the user cannot import schematics that have been remapped.

Fixes lp:1791280

https://bugs.launchpad.net/kicad/+bug/1791280
2018-10-24 15:38:02 -04:00
Jeff Young 8a54b1b3b7 Add view refresh calls for edit operations.
Note that the bug referenced in the "fixes" section is only one
of many addressed by this commit.

Fixes: lp:1798449
* https://bugs.launchpad.net/kicad/+bug/1798449
2018-10-18 12:12:48 +01:00
Jeff Young 2d5baac77d Fix up zoom and pan issues entering/leaving sheets. 2018-10-09 11:08:56 +01:00
Tomasz Wlostowski 90c7c60471 eeschema-gal: initial GALified version. Lots of stuff still to do! 2018-10-09 11:08:52 +01:00
Wayne Stambaugh 3c86bc951a Eeschema: fix yet another lock file issues.
Reset lock file when saving a schematic sheet to a different file name.
This prevents a file is already open error from being displayed when
opening the original file.

Fixes lp:1788507

https://bugs.launchpad.net/kicad/+bug/1788507
2018-09-24 08:59:03 -04:00
Jeff Young e45afdb912 Revert absolute-path asserts and fix off-by-one bug.
Fixes: lp:1767582
* https://bugs.launchpad.net/kicad/+bug/1767582
2018-09-15 22:36:09 +01:00
Jeff Young 872e1e6532 Remove asserts for absolute paths.
You can, for instance, specify relative paths via the command
line.

Fixes: lp:1767582
* https://bugs.launchpad.net/kicad/+bug/1767582
2018-09-15 20:06:42 +01:00
Jeff Young 4b1a31ffad Regularize save-changes dialogs. 2018-08-12 00:02:37 +01:00
Jeff Young d8d4f75fa1 Fix button order and genralize Exit dialog so it can be shared more.
This also fixes a bunch of bugs where an error during save would
still close the window (rather than cancelling the close action).

Fixes: lp:1785034
* https://bugs.launchpad.net/kicad/+bug/1785034
2018-08-02 11:01:03 +01:00
Jeff Young cb61525394 Handle separate parsing rules for ID_SCH and ID_PCB.
This removes the existing constructors so that all parsing must
be explicit and callers are made aware that they need to think
about illegal characters, malformed ids, etc.

Fixes: lp:1783474
* https://bugs.launchpad.net/kicad/+bug/1783474
2018-07-26 15:43:53 +01:00
Jeff Young aa7da5dfcd Treat ${...} and $(...) envvar references uniformly.
Fixes: lp:1769282
* https://bugs.launchpad.net/kicad/+bug/1769282
2018-05-05 23:40:40 +01:00
Jeff Young 21ceb786ac Clear annotations *after* rebuilding symbol links.
We need to symbol links to determine whether or not units are
locked (ie: non-interchangeable).

Fixes: lp:1767744
* https://bugs.launchpad.net/kicad/+bug/1767744
2018-04-29 15:09:28 +01:00
Maciej Suminski 554cb54a4f Eagle SCH import: save project file after the full path is set
Fixes: lp:1765297
* https://bugs.launchpad.net/kicad/+bug/1765297
2018-04-20 10:04:41 +02:00
Wayne Stambaugh 81843c37a4 Organize trace debugging code for ease of maintenance. 2018-04-13 09:59:01 -04:00
Maciej Suminski 58c27398cb Eagle SCH import: improved implicit connections resolution
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.

Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
2018-04-12 18:12:22 +02:00
Wayne Stambaugh 696ff81dc7 Load correct schematic page layout description file in stand alone mode.
Fixes lp:1678849

https://bugs.launchpad.net/kicad/+bug/1678849
2018-04-04 10:18:12 -04:00
Maciej Suminski 2af51ef20f Eagle import: do not call TrimWire() on imported schematics
It turns out that TrimWire() may remove legit Eagle wires and effectively
change the netlist.
2018-03-04 18:04:19 +01:00
Maciej Suminski 260f680c6c Eagle import: fix memory leak on schematic sheets import 2018-03-04 16:47:26 +01:00
Maciej Suminski 8e8d95dd7f Eagle import: process all sheets when adding junctions; fix footprint LIB_IDs 2018-03-04 16:45:42 +01:00
Maciej Suminski 77346d81ce Eagle import plugin: add junction dots to fix connectivity 2018-03-04 16:45:42 +01:00
Maciej Suminski 1f078f533b Refactor Eagle project import to use Kiway::ExpressMail() 2018-03-04 16:45:42 +01:00
Wayne Stambaugh aeae32b1a2 Fix file naming bug when importing Eagle projects with . in file name.
Fixes lp:1747470

https://bugs.launchpad.net/kicad/+bug/1747470
2018-03-03 08:35:53 -05:00
Jeff Young 4dda8a39fe Add inc/dec current layer alpha to menus.
Also adds indicators in layers palette for feedback.
Also generates sized images for all indicators instead of using
scaled bitmaps (which didn't look great).
Also fixes a completely unrelated typo in a UI string.
2018-02-22 17:48:14 +01:00