Aliases in bus resolution were being resolved without a path, making
them effectively global nets. This applies the corrected path to the
bus members and adds a QA to catch this error
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
(cherry picked from commit 831a6d55fc)
Also removes auto-closing of blocking dialogs when inserting
symbols from the Symbol Editor or Chooser, preventing the bug
that QuasiModel was removed for earlier.
Also fixes a non-initialized parent pointer when the TextBox
Properties dialog was called from DrawShape().
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14777
(cherry picked from commit 5a9ed66cfd)
Spice parameters were converted to lower-case before comparison. This is incorrect, as it
is legal and common for spice parameters to contain capital letters (e.g. potentiometers
typically use Rt and SET as their parameters).
Spice parameters are not case sensitive, so the correct behaviour is to instead do a
case-insensitive comparison on the parameter name.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14793
(cherry picked from commit 0d235ac64b)
(cherry picked from commit 888a35bbde)
Spice parameters were converted to lower-case before comparison. This is incorrect, as it
is legal and common for spice parameters to contain capital letters (e.g. potentiometers
typically use Rt and SET as their parameters).
Spice parameters are not case sensitive, so the correct behaviour is to instead do a
case-insensitive comparison on the parameter name.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14793
(cherry picked from commit 0d235ac64b)
- honor mirroring of fields attached to labels (all types)
- fix incorrect orientation of the graphic shape of SCH_DIRECTIVE_LABEL items
after mirroring the item.
Form master branch
Fixes#14758https://gitlab.com/kicad/code/kicad/issues/14758
Version 7 text alignment changed subtly for stroke fonts from version 6.
Additionally, the output has been different between screen and plotting,
leading to offset text in plotted output relative to the text shown on
screen.
This introduces a fudge factor in FONT::getLinePositions to correct the
offset in the plotting output relative to v6.
This also changes the SCH_PAINTER and PCB_PAINTER to correct the
relative offsets between GAL and PLOTTER classes. The source of these
offsets is atm unclear.
Fixes https://gitlab.com/kicad/code/kicad/issues/14755
(cherry picked from commit 0de24bfd59)
The propagation is currently (maybe not needed) limited to the global
name that is the source of the change. We also need to propagate the
global name that is changed in case the global is set in a tree leaf and
not the root
Fixes https://gitlab.com/kicad/code/kicad/issues/14657
(cherry picked from commit 6e4de18e15)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
The netlist exporter was never updated to exclude symbols that are
tagged as power symbols. Only the legacy power symbol name prefix
('#') was used as the power symbol check. Power symbols no longer
require the '#' name prefix.
(cherry picked from commit fb6b8eaeea)
Needs to be static, so keep the reference from the associated symbol and
not the SCH_SYMBOL instance. Both will likely have the same prefix,
which is all we care about here
(cherry picked from commit 2cac992801)
We're going to use the dataStore to update the symbol, so
if we store resolved values it will nuke any text variables
even if the field wasn't edited.
Not sure if the BOM generator has a separate resolve-variables
step or not. But it will need one as the code removed here
only worked for Values and Footprint fields anyway.
Settings should be initialized on start-up. This removes the option of
lazily loading the settings from file and instead requires all settings
needed to be loaded on KiFACE start before requesting data from the
settings object
(cherry picked from commit e6ab9a88ce)
- Ensure that critical paths (ERC/netlister) are fully-rechecked
- Handle symbol/pin distinction in change markers
- Fully connect hierarchical pins in one pass descending
(cherry picked from commit 6e8a5acc66)
Previously, almost all connectivity updates were full updates, meaning
that the entire connectivity graph would be rebuilt each time a change
was made to the schematic. This update modifies the update to only
correct the subgraphs that are directly affected by the change.
It uses the existing connection graph to find all affected subgraphs as
well as connections to the changes based on the visible schematic.
These elements are removed from the existing connectivity graph and
marked dirty. They then have a new connectivity graph built only around
their changes. The resulting graph is merged into the original.
Currently, this ability is behind an advanced config flag
`IncrementalConnectivity` while testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10846
Fixes https://gitlab.com/kicad/code/kicad/issues/1794
(cherry picked from commit a154571438)
The spacemouse driver, particularly on Mac, is extremely unstable and
causes crashes even when not being used. This places the interface
behind an advanced config flag to ensure that users can affirmatively
opt-in to the potential for crashes
(cherry picked from commit 2cd854af14)
1) Don't read libraries multiple times
2) VDMOS default is nchan if not specified
3) In the absence of a workbook default to LTSpice compatability
4) Don't attempt to write out a model line for a subckt; it never has
a baseModel
Previously, bus elements that were not instantiated as individual nets
could not connect to each other. This caused issues for complex
schematics where busses needed to connect to other busses with elements
that resolved to the same net names. Functionally, this means mixing
bus elements, which we will replace with first-class elements in version
8 but currently can only be accomplished either by using bus aliases and
this patch or by individually instantiating each bus element as a
local label
Fixes https://gitlab.com/kicad/code/kicad/issues/14300
(cherry picked from commit 16b4ec3c7e)
- Ensure the first field in m_fields has id = 0 to be seen has hypertext
(it was not the case after reading a .kicad_sch file)
- when converting this item to another label/text, remove this special Field
from the copied field list to the converted label.
From master branch.
(The real bug here is that CONNECTION_GRAPH::assignNetCodesToBus() was
growing the bus aliases members list because it used a non-const
reference to it as a local storage list. The const scoping of it will
prevent this type of error in future.)
Fixes https://gitlab.com/kicad/code/kicad/issues/14269
Also fixes a bug where all VDMOS instance parameters weren't marked as
instance parameters.
Also fixes a bug where VDMOS thermal models weren't supported (they
have two extra pins: Tj and Tcase).
(cherry picked from commit 5bda3b99f9)
The list of candidates (names) must be restricted to existing global labels
and symbols creating a global net name: power symbols having only one power
input pin (a power output does not create net name).
Fixes#14319https://gitlab.com/kicad/code/kicad/issues/14319
In symbol editor, symbols are always shown not mirrored, not rotated.
So if the loaded symbol from schematic was rotated/mirrored, the position
of fields must be recalculated for the rotation 0, no mirror.
From master branch
- Consistent calculation of IsStacked() for pins across ERC checks
- Correct placement of ERC marker for unresolved field variables
- Add sheet-specific paths to two ERC check results
(cherry picked from commit 39e56485fc)
Fixes#12580
Additionally does not export no_connect netlist annotation on pins
which are both connected to another pin and a NC item, unless all
connected pins are stacked at the symbol level.
Adds testing of pin types to netlist QA unit tests.
(cherry picked from commit 9dca70a773)