At one point, all of the footprints provided by the KiCad footprint
libraries were merged into a single pdf file. The link to open this
file was provided on the toolbar. Since the footprint libraries have
been split out into individual repositories, this file is no longer
created so the toolbar button and the underlying code to open this
file were removed.
Improve a few CvPcb menu strings.
Fixes lp:702785
https://bugs.launchpad.net/ubuntu/+source/kicad/+bug/702785
*) Extend SWIG support deeper into the BOARD class.
*) Move swig *.i files into a directory identified for SWIG, in preparation
for a parallel universe involving Phoenix's SIP.
*) Move swig files which will be common to both eeschema and pcbnew into
common/swig.
*) Sketch out a "common" python module, and plan on dovetailing that into a
libkicad_shared.{dll,so}
*) Add common/swig/ki_exceptions.i and define a macro HANDLE_EXCEPTIONS()
which is to be applied to any function which needs C++ to python
exception translation.
*) Move the test for SWIG tool into top level CMakeLists.txt file for use
in all python modules beyond pcbnew, i.e. eeschema and common.
*) Add SWIG_MODULE_pcbnew_EXTRA_DEPS which generates a better Makefile, one
which rebuilds the swig generated *.cxx file when one of its dependencies
change.
*) Re-architect the board.i file so that it can be split into multiple *.i
files easily.
*) Make some KIWAY from python progress, in preparation for Modular KiCad
phase III.
This option is not yet activated because the net attributes are not yet fully fixed by Ucamco, in Gerber file format specifications.
(To activate it, see dialog_plot.cpp, line 43)
* When Pcbnew is launched in the stand alone mode with no board file command
line option, the project path is set to the current working directory. The
user may not have write access to the current working directory which would
cause the auto save to generate an error. If the user does not have write
access to the current working directory, set the path to a platform specific
temporary path that the user has write permission.
* When Pcbnew is launched in the stand alone mode with no board file command
line option, the default BOARD object has no file name. Set the file name
to "noname.kicad_pcb" to fix incorrect auto save file name and set the path
to the user's platform specific document folder.
* Delete orphaned auto save files when closing without saving due to broken
auto save file generation logic which prepended the file name with "$" rather
than "_autosave-".
* Fixes: lp:1596382