Gerhard Sittig 2c33b09255 asix-sigma: eliminate magic numbers in sample memory access
Add more symbolic identifiers, and rename some of the existing names for
access to SIGMA sample memory. This eliminates magic numbers and reduces
redundancy and potential for errors during maintenance.

This commit also concentrates DRAM layout related declarations in the
header file in a single location, which previously were scattered, and
separated registers from their respective bit fields.

Extend comments on the difference of events versus sample data.
2020-05-29 07:50:18 +02:00
Gerhard Sittig 7c41c420aa asix-sigma: move FPGA commands before register layout declaration
Move the FPGA commands (which can access registers, and sample memory)
declarations before the register layout declaration. Which then no
longer separates the registers declarations from their bit fields.
Update comments on the register set while we are here.
2020-05-29 07:50:18 +02:00
Gerhard Sittig 07411a605e asix-sigma: rephrase some of the FPGA command exchange
Eliminate a few magic numbers in FPGA commands, use symbolic identifiers
for automatic register address increments, and DRAM access bank selects.
Improve grouping of related declarations in the header file.
2020-05-29 07:49:58 +02:00
Gerhard Sittig 9fb4c6324d asix-sigma: sync FPGA register names with documentation
Rename source code identifiers for FPGA registers to closer match the
vendor's documentation.
2020-05-29 07:49:58 +02:00
Gerhard Sittig dc0906e21c asix-sigma: eliminate magic numbers in FPGA configuration
Slightly rephrase and comment on the FPGA configuration of the ASIX
SIGMA logic analyzer. Use symbolic pin names to eliminate magic numbers.
Concentrate FPGA related comments in a single spot, tell the Xilinx FPGA
from FTDI cable (uses bitbang mode for slave serial configuration).

This fixes typos in the PROG pulse and INIT check (tests D5 and comments
on D6). Also removes the most probably undesired 100s timeout in the
worst case (100M us, 10K iterations times 10ms delay). Obsoletes labels
for error paths. Drops a few empty lines to keep related instruction
blocks together. Includes other style nits.
2020-05-29 07:49:58 +02:00
Gerhard Sittig 53a939aba5 asix-sigma: rework scan for USB devices, add support for conn= specs
Stick with the FTDI library for data acquisition, and most of all for
firmware upload (bitbang is needed during FPGA configuration). Removing
this dependency is more complex, and needs to get addressed later.

Re-use common USB support during scan before open, which also allows to
select devices if several of them are connected. Either of "conn=vid.pid"
or "conn=bus.addr" formats are supported and were tested.

This implementation detects and displays SIGMA and SIGMA2 devices. Though
their function is identical, users may want to see the respective device
name. Optionally detect OMEGA devices, too (compile time option, off by
default), though they currently are not supported beyond detection. They
just show up during scans for ASIX logic analyzers, and users may want to
have them listed, too, for awareness.

This implementation also improves robustness when devices get disconnected
between scan and use. The open and close routines now always create the
FTDI contexts after the code has moved out of the scan phase, where common
USB support code is used.

This resolves bug #841.
2020-05-29 07:49:50 +02:00
Gerhard Sittig 742368a2bc asix-sigma: nits in the list of firmware files
Eliminate an unnecessary magic number for the maximum filename length of
SIGMA netlists. Use a more compact source code phrase to "unclutter" the
list of filenames and their features/purpose. Move the filesize limit to
the list of files to simplify future maintenance.
2020-05-29 06:13:41 +02:00
Gerhard Sittig 97aa41e9b5 strutil: introduce sr_atol_base() conversion helper (non-decimal)
Introduce a text to number conversion routine which is more general than
sr_atol() is. It accepts non-decimal numbers, with optional caller given
or automatic base, including 0b for binary. It is not as strict and can
return the position after the number, so that callers can optionally
support suffix notations (units, or scale factors, or multiple separated
numbers in the same text string).
2020-05-29 06:12:50 +02:00
Gerhard Sittig 080b6bcf09 libsigrok-internal.h: add 24bit little endian reader helper
Add another endianess conversion helper which reads 24bit values in
little endian format.
2020-05-29 06:11:38 +02:00
Gerhard Sittig f1833600a0 libsigrok-internal.h: rephrase endianess conversion helpers
Address style, robustness, and usability nits in the common endianess
conversion helpers in the libsigrok-internal.h header file. Rephrase
preprocessor macros as static inline C language functions to eliminate
side effects, and improve data type safety. Provide macros under the
previous names for backwards compatibility, so that call sites can
migrate to the routines at their discretion (or not at all).

Performance is not affected. Inline routines are identically accessible
to compiler optimizers as preprocessor macros with their text expansion
are. Resulting machine code should be the same.

Introduce variants which also increment the read or write position in
the byte stream after data transfer. This reduces more redundancy at
call sites.
2020-05-29 06:10:18 +02:00
Frank Stettner 883db4dad1 hp-3478a: Fix glib variant ref count in SET MQ request. 2020-05-26 21:17:32 +02:00
Frank Stettner 1c8110dbc7 scpi-dmm: Fix coding style. 2020-05-26 21:17:25 +02:00
Tobias Faeth 6d2e307016 serial-dmm: Added support for Metex ME-21 multimeters 2020-05-26 21:11:48 +02:00
Sergey Rzhevsky 9785891436 ftdi-la: Add FT4232H PID:VID. 2020-05-02 17:01:39 +02:00
Richard 77f3c5e51f rigol-ds: Added support for the DS1202Z-E 2020-05-02 17:01:39 +02:00
Gerhard Sittig 8c381a353c hameg-hmo: use common helper to setup description of an analog value
Replace an open coded sequence of assignments to an aggregate of several
related structures. Prefer the common sr_analog_init() routine instead.
2020-05-02 17:01:39 +02:00
Gerhard Sittig 00f3c94386 uni-t-ut32x: drop redundant close and free at end of scan
The UT32x driver requires a user spec for the connection. The device
cannot get identified, that's why successful open/close for the port
will suffice. Lack of an input spec as well as failure in the early
scan phase will terminate the scan routine early.

When we reach the end of the scan which creates the device instance
and registers it with the list of found devices, the port already
is closed and the list of devices will never be empty. Remove the
redundant close call and the dead branch which frees the serial port.
2020-05-02 17:01:39 +02:00
Gerhard Sittig ff5fb18526 scpi-dmm: fix glib variant ref count in SET MQ request 2020-05-02 17:01:39 +02:00
Uwe Hermann 6cfc6c5c7a Fix compiler warnings related to -Wcast-function-type.
This fixes bug #1297.
2020-05-02 17:01:39 +02:00
Uwe Hermann 4c5ac0cf5b siglent-sds: Fix various compiler warnings.
src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_get_digital':
  src/hardware/siglent-sds/protocol.c:382:35: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
          if (data_low_channels->len <= samples_index) {
                                     ^
  src/hardware/siglent-sds/protocol.c:391:36: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
          if (data_high_channels->len <= samples_index) {
                                      ^
  src/hardware/siglent-sds/protocol.c:417:32: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
       for (long index = 0; index < tmp_samplebuf->len; index++) {
                                  ^
  In file included from src/hardware/siglent-sds/protocol.c:37:0:
  src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_receive':
  src/hardware/siglent-sds/protocol.h:28:20: warning: format '%li' expects argument of type 'long int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
   #define LOG_PREFIX "siglent-sds"
                      ^
  ./src/libsigrok-internal.h:815:41: note: in expansion of macro 'LOG_PREFIX'
   #define sr_dbg(...) sr_log(SR_LOG_DBG,  LOG_PREFIX ": " __VA_ARGS__)
                                           ^
  src/hardware/siglent-sds/protocol.c:564:6: note: in expansion of macro 'sr_dbg'
        sr_dbg("Requesting: %li bytes.", devc->num_samples - devc->num_block_bytes);
        ^
  src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_get_dev_cfg_horizontal':
  src/hardware/siglent-sds/protocol.h:28:20: warning: format '%lu' expects argument of type 'long unsigned int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
   #define LOG_PREFIX "siglent-sds"
                      ^
  ./src/libsigrok-internal.h:815:41: note: in expansion of macro 'LOG_PREFIX'
   #define sr_dbg(...) sr_log(SR_LOG_DBG,  LOG_PREFIX ": " __VA_ARGS__)
                                           ^
  src/hardware/siglent-sds/protocol.c:933:2: note: in expansion of macro 'sr_dbg'
    sr_dbg("Current memory depth: %lu.", devc->memory_depth_analog);
    ^
2020-05-02 15:48:26 +02:00
Andreas Sandberg 4704f64551 bt/bt_bluez: Implement retry if rfcomm sockets are busy
There are cases where the connect() call returns EBUSY when trying to
connect to a device. This has been observed when sampling an RDTech
UM24C. In this case, scanning the device works fine. However, when
sampling the device, Sigrok first scans the device, then closes the
connection and re-opens it to sample the device. If the close/open
calls happen in close successions, the Bluetooth stack sometimes
returns EBUSY.

Work around this issue by retrying if the connect() returns EBUSY.

Signed-off-by: Andreas Sandberg <andreas@sandberg.pp.se>
2020-04-11 16:00:52 +02:00
v1ne 1d657f47be modbus: Close device after scan
Since the device should be closed after the scan, close it in sr_modbus_scan.
Alternatively, every single driver could close the device after calling
sr_modbus_scan. This causes duplicated code, is prone to forgetting it and it
wasn't the calling driver who opened the device in the first place.

This change unbreaks maynuo-m97 and rdtech-dps.
2020-04-11 15:55:35 +02:00
Florian Schmidt 8f3c77db26 scpi-pps: fixed out-of-bounds array access...
when accessing devc->device->channels in config_list().
this array has to be accessed via the "hw_output_idx"

This fixes bug #1533.
2020-04-11 15:52:13 +02:00
Uwe Hermann f0aec55605 center-3xx: Fix incorrect values due to endianness issue.
Replace RL16S with RB16S, the values are big-endian.

This is related to the recently-fixed bug #1463.
2020-04-09 23:51:16 +02:00
Uwe Hermann 4c5f70063a Use std_session_send_df_frame_begin()/_end() where possible. 2020-04-08 23:54:25 +02:00
Uwe Hermann 7f7702b81b std: Rename std_session_send_frame_begin/_end(). 2020-04-08 23:35:44 +02:00
Uwe Hermann 0fa71943e3 Use std_session_send_df_trigger() where possible. 2020-04-08 23:21:39 +02:00
Uwe Hermann 447c4216fc std: Factor out send_df_without_payload() helper. 2020-04-08 23:11:15 +02:00
Uwe Hermann 10cf811385 std: Add std_session_send_df_trigger(). 2020-04-08 23:02:04 +02:00
Uwe Hermann 148cf8bea1 zeroplus-logic-cube: Fix an issue when changing triggers.
Changing triggers (e.g. from low to high) would sometimes cause the
acquisition to seemingly "hang" due to missing variable initializations
(in reality the device would wait for incorrect triggers and/or on
incorrect channels).

This fixes bug #1535.
2020-04-08 22:58:02 +02:00
Jan Metzger 88daa0536c zeroplus-logic-cube: Enable edge-triggering capabilities.
This fixes bug #1334.
2020-04-08 22:57:02 +02:00
Christian Fruth c8dcd3ab72 korad-kaxxxxp: Add support for RND KA3005P V5.5 power supply 2020-04-07 00:54:18 +02:00
Peter van der Perk 082ca8d8bc korad-kaxxxxp: Add support for TENMA 72-2540 V5.2 power supply 2020-04-07 00:54:18 +02:00
Tom Matthews 3ff6cfeebe ftdi-la: add TUMPA VID:PID and JTAG pin names 2020-04-07 00:54:18 +02:00
v1ne 69c5d959e7 rdtech-dps: Make it work in SmuView
Without the mutex, concurrent reception from the ModBus port leads to CRC
errors.
2020-04-04 23:25:25 +02:00
Gerhard Sittig 56a1bf7b4b center-3xx: use common signed LE16 conversion for temperature value
Prefer the common conversion helper for little endian 16bit signed data.
The previous local implementation only worked for positive values, and
yielded incorrect results for negative temperatures.

This fixes bug #1463.
2020-04-04 23:25:25 +02:00
Elen Eisendle ca7d442692 serial-dmm/uni-t-dmm: Add UNI-T UT804 DMM definitions 2020-04-04 23:25:09 +02:00
Andreas Sandberg 35037b1d8b input/trace32_ad: Fix pod_data uninitialised warning
Signed-off-by: Andreas Sandberg <andreas@sandberg.pp.se>
2020-04-04 22:25:03 +02:00
Andreas Sandberg 5ff772410b gwinstek-gpd: Fix use of uninitialized variable
Signed-off-by: Andreas Sandberg <andreas@sandberg.pp.se>
2020-04-04 22:24:26 +02:00
Uwe Hermann 6762401d2b Doxygen: Fix various warnings.
src/resource.c:414: warning: unbalanced grouping commands

  conversion.c:81: warning: argument 'lo_thr' from the argument list of sr_a2l_schmitt_trigger has multiple @param documentation sections

  src/analog.c:611: warning: return value 'SR_ERR_ARG' of sr_rational_div has multiple documentation sections

  src/device.c:205: warning: explicit link request to 'TRUE' could not be resolved
  src/device.c:205: warning: explicit link request to 'FALSE' could not be resolved
  src/device.c:231: warning: explicit link request to 'TRUE' could not be resolved
  src/device.c:231: warning: explicit link request to 'FALSE' could not be resolved

  src/serial.c:246: warning: explicit link request to 'NULL' could not be resolved

  src/strutil.c:602: warning: explicit link request to 'NULL' could not be resolved

  src/device.c:94: warning: unable to resolve reference to 'sr_channel_free()' for \ref command

  src/strutil.c:597: warning: unable to resolve reference to 'sr_hexdump_free()' for \ref command
  src/strutil.c:622: warning: unable to resolve reference to 'sr_hexdump_new()' for \ref command

  src/device.c:430: warning: The following parameters of sr_dev_inst_channel_add(struct sr_dev_inst *sdi, int index, int type, const char *name) are not documented: parameter 'sdi'

  src/session.c:163: warning: The following parameters of fd_source_new(struct sr_session *session, void *key, gintptr fd, int events, int timeout_ms) are not documented: parameter 'events'
2020-03-25 20:27:57 +01:00
Uwe Hermann 82b9f3d116 Doxygen: Properly mark a few symbols as private.
(otherwise these end up in the API docs)

Remove all @internal markings, only use @private where needed.
2020-03-25 20:10:24 +01:00
Uwe Hermann 20680f58ff manson-hcs-3xxx: Support device IDs with and without "HCS-" prefix.
Since we've now seen lots of devices in the wild that come with the
"HCS-" prefix in the ID, it's probably safe to assume all of them
could have it.

This fixes bug #1530.
2020-03-24 21:10:27 +01:00
Uwe Hermann bfa79fbdb6 asix-sigma: Drop duplicate error message prefixes.
The sr_err() call automatically adds a prefix to all messages, in
this specific case "asix-sigma: " will be added.
2020-03-24 19:22:11 +01:00
Daniel Trnka 440810958c asix-sigma: move DRAM line buffer allocation closer to its use
Move the allocation of the DRAM line buffer in the sample download code
path closer to the location where that buffer is used and gets released.
2020-03-24 19:20:40 +01:00
Daniel Trnka f73b00b647 asix-sigma: check for successful register access in sample download
The previous implementation got stuck in an infinite loop when data
acquisition started, but the device got disconnected before the data
acquisition terminates. An implementation detail ignored communication
errors, and never saw the expected condition that was required to
continue in the sample download sequence. Unbreak that code path.
2020-03-24 19:20:40 +01:00
Uwe Hermann f5c863e572 korad-kaxxxxp: Fix max. possible current for all devices.
Even though the devices/websites/manuals usually say 0..30V, the
hardware actually accepts up to 31V, both via serial as well as by
simply rotating the knob on the device (and our driver already
reflects that).

The same is true for current, it's usually 0..5A as per docs, but many
(probably all) devices accept 5.1A via serial and knob.

Thus, set the max current of all devices to 5.1A (or 3.1A for 3A
devices). We're assuming they all have this property, and we've seen
this in practice on at least three different versions of the device.
2020-03-22 16:58:54 +01:00
David Sastre Medina 7415217ede korad-kaxxxxp: Add a new ID for KORAD KA3005P V4.2 power supply
On a recently acquired Korad KA3005P power supply, the ID supplied by the
device is not known by libsigrok.

$ sigrok-cli --driver=korad-kaxxxxp:conn=/dev/ttyACM0 --scan
sr: korad-kaxxxxp: Unknown model ID 'KORAD KA3005P V4.2' detected, aborting.

This fixes bug #1522.

Thanks to bitaround@gmail.com for the amperage fix.
2020-03-22 15:52:16 +01:00
jirjirjir c4a46475a6 rigol-ds: Rigol DS1152E-EDU support fix 2020-03-16 23:44:25 +01:00
Soeren Apel 781ae4484d Fix #1509 by providing alternate sample format scales 2020-02-28 23:26:20 +01:00
Uwe Hermann f0362f595a agilent-dmm: Add Agilent U1237AX (completely untested). 2019-12-27 22:08:41 +01:00