The driver should now be able to cope with e.g. multiple ChronoVu LA8
and/or ChronoVu LA16 devices being connected to the same PC.
It now also provides the serial number and connection ID, which can be
used by frontends to differentiate multiple devices.
Also improve the scanopts / drvopts / devopts lists handling.
This fixes bug #504.
Set both CFLAGS and CXXFLAGS when executing setup.py to build
the Python bindings. Newer versions of distutils/setuptools have
apparently started to pick up the latter when compiling C++.
Check for either Python 2 or Python 3 header files depending on
the version of the Python interpreter. Also require the module
version to exactly match the interpreter version.
This may fix bug #645.
With the current driver API and the corresponding session event
handling, it is not possible to destroy and then re-create an
event source with the same key within the same main loop iteration.
The next generation driver API will fix this problem. But for now,
just change the driver to make do without that sort of thing. Also
increase the I/O timeout to 100 ms to be safer in the event of all
kind of delays the OS environment may induce.
This fixes bug #678.
Evaluate all 64 bit of the duration field in the capture status
record. Although unlikely in practical use, due to compression
it is possible for the duration in ms to exceed 32 bit.
zip_discard() was introduced in libzip 0.11, which some systems
do not have yet. Provide a fallback replacement for zip_discard(),
and reduce the requirement to libzip 0.10 again.
This fixes bug #674.
std::default_delete<> is originally defined as struct, not class.
This does not really make much of a difference, but some compilers
complain when the struct/class tag is not consistent across all
declarations of the type.
Make the Python and Java bindings use the same set of preprocessor
macros for the SWIG parsing stage, taken from a make variable. Add
G_GNUC_{BEGIN,END}_IGNORE_DEPRECATIONS to that set.
During initialization of the LWLA1034, read the 64-bit test word
twice and verify the result of the second read only. This better
matches what the original vendor software does.
Apparently, these four registers form an interface for indirect
access to another internal 64 bit wide memory. This is likely the
same memory as that accessed by the bulk transfer commands 7 and 8.
Added support for SR_CONF_REGULATION which returns value for CH1
Also VELLEMAN LABPS3005D (only device currently supported) sends single
'M' character in beginning of return value, which is specially discarded.
Writing to an object through a pointer of incompatible type is
really evil. Even when the data size matches, it is still a
violation of strict aliasing rules.
Replace all instances by direct casts of the value, without the
unnecessary and dangerous indirection.
The Java bindings currently have some weird problem with function
arguments passed by const reference. Not all types are affected,
but the collection types that involve custom typemaps are.
For now, revert back to pass-by-value for the problematic types.