Commit Graph

119 Commits

Author SHA1 Message Date
Håvard Espeland a42aec7f6e Sigma: Merge storage of rise/fall triggers. 2010-05-03 15:06:43 +02:00
Håvard Espeland 4ae1f45136 Sigma: Minor cleanups. 2010-05-02 21:59:14 +02:00
Håvard Espeland 11fc8d9d93 Sigma: Set capture ratio correctly. 2010-05-02 21:59:14 +02:00
Håvard Espeland c53d793f03 Sigma: 50 MHZ falling/rising edge trigger support.
Falling/rising edge and value/mask triggers can be combined, e.g.:
  --triggers 1=0,2=r,3=1,4=1
2010-05-02 16:32:24 +02:00
Håvard Espeland f758d0744d Sigma: Fix simple trigger LUT calculation. 2010-05-02 13:00:41 +02:00
Håvard Espeland ee492173a1 Sigma: Value/mask trigger support in 50 MHz mode. 2010-05-01 23:16:27 +02:00
Håvard Espeland eec5275e2f Sigma: Small cleanups. 2010-05-01 23:16:18 +02:00
Håvard Espeland 57bbf56b84 Sigma: Add triggers support for 100 and 200 MHz. 2010-05-01 00:00:57 +02:00
Håvard Espeland ed09fd07f7 Sigma: Minor cleanup and add more samplesrates. 2010-04-30 23:54:14 +02:00
Uwe Hermann 9ddb2a125d Sigma: Small cosmetic fixes. 2010-04-29 00:32:44 +02:00
Håvard Espeland edca2c5c22 Sigma: Support for low samplerates
Lowest samplerate supported in driver is 250 KHz
2010-04-28 22:45:13 +02:00
Håvard Espeland f78898e947 Sigma: Support 50 and 200 MHz modes 2010-04-28 21:24:41 +02:00
Håvard Espeland a8116d764b Sigma: Rename firmware files 2010-04-28 21:20:27 +02:00
Håvard Espeland e8397563a2 Sigma: Upload 50, 100 or 200 MHz firmware 2010-04-28 20:01:15 +02:00
Håvard Espeland f6564c8d19 Sigma: Move upload firmware into a function 2010-04-28 19:51:13 +02:00
Uwe Hermann fefa18001a ASIX SIGMA: Coding style fixes (via indent mostly).
Also, end all/most comments with full stop and avoid variable/array
definitions in the middle of functions.
2010-04-28 00:17:28 +02:00
Uwe Hermann 204b1629bd asix-sigma.h: Add missing license header. 2010-04-27 22:46:59 +02:00
Uwe Hermann 911f18341b ASIX Sigma: Use common license header format. 2010-04-27 22:44:15 +02:00
Håvard Espeland 28a35d8ab3 This commit adds initial support for the Asix Sigma Logic Analyzer. Currently, only 200 MHz is supported, and only with software trigger. Firmware for the device will be distributed separately, with permission from the vendor.
Signed-off-by: Håvard Espeland <gus@ping.uio.no>
2010-04-27 13:16:01 -07:00